The aim of the study is to investigate the contents of trace element Se, Cd, Pb in three plants including burdock, ginkgol and garlic via graphite furnace atomic absorption and standard addition method. The results sh...The aim of the study is to investigate the contents of trace element Se, Cd, Pb in three plants including burdock, ginkgol and garlic via graphite furnace atomic absorption and standard addition method. The results show that Se in burdock stem, skin and leaf are 32.40, 48.63, 38.10 μg/g, respectively; Cd in burdock stem, skin and leaf are 0. 160 0, 0. 300 0, 0. 140 0 μg/g, respectively; Cd in burdock stem, skin and leaf are 2. 020, 3. 960, 2. 410 μg/g, respectively. In the ginkgo and ginko leaf, Se contents are 17.63 and 16.91 μg/g, respectively ; for Cd are 0. 181 0 and 0.2020μg/g, respectively ; for Pb are 3. 572 and 4. 021 μg/g, respectively. In garlic, Se, Cd and Pb are 73. 900 0, 6. 900 0 and 0. 390 0, respectively. All the standard deviations of measured results are below 2.3%, recovery rate are from 99% to 101%.展开更多
Determination of chemical elements assay plays an important role in mineral processing operations.This factor is used to control process accuracy,recovery calculation and plant profitability.The new assaying methods i...Determination of chemical elements assay plays an important role in mineral processing operations.This factor is used to control process accuracy,recovery calculation and plant profitability.The new assaying methods including chemical methods,X-ray fluorescence and atomic absorption spectrometry are advanced and accurate.However,in some applications,such as on-line assaying process,high accuracy is required.In this paper,an algorithm based on Kalman Filter is presented to predict on-line XRF errors.This research has been carried out on the basis of based the industrial real data collection for evaluating the performance of the presented algorithm.The measurements and analysis for this study were conducted at the Sarcheshmeh Copper Concentrator Plant located in Iran.The quality of the obtained results was very satisfied;so that the RMS errors of prediction obtained for Cu and Mo grade assaying errors in rougher feed were less than 0.039 and 0.002 and in final flotation concentration less than 0.58 and 0.074,respectively.The results indicate that the mentioned method is quite accurate to reduce the on-line XRF errors measurement.展开更多
基金School Fund of Xuzhou Institute of Technology (XKY200614)~~
文摘The aim of the study is to investigate the contents of trace element Se, Cd, Pb in three plants including burdock, ginkgol and garlic via graphite furnace atomic absorption and standard addition method. The results show that Se in burdock stem, skin and leaf are 32.40, 48.63, 38.10 μg/g, respectively; Cd in burdock stem, skin and leaf are 0. 160 0, 0. 300 0, 0. 140 0 μg/g, respectively; Cd in burdock stem, skin and leaf are 2. 020, 3. 960, 2. 410 μg/g, respectively. In the ginkgo and ginko leaf, Se contents are 17.63 and 16.91 μg/g, respectively ; for Cd are 0. 181 0 and 0.2020μg/g, respectively ; for Pb are 3. 572 and 4. 021 μg/g, respectively. In garlic, Se, Cd and Pb are 73. 900 0, 6. 900 0 and 0. 390 0, respectively. All the standard deviations of measured results are below 2.3%, recovery rate are from 99% to 101%.
基金the support of the Department of Research and Development of Sarcheshmeh Copper Plants for this research
文摘Determination of chemical elements assay plays an important role in mineral processing operations.This factor is used to control process accuracy,recovery calculation and plant profitability.The new assaying methods including chemical methods,X-ray fluorescence and atomic absorption spectrometry are advanced and accurate.However,in some applications,such as on-line assaying process,high accuracy is required.In this paper,an algorithm based on Kalman Filter is presented to predict on-line XRF errors.This research has been carried out on the basis of based the industrial real data collection for evaluating the performance of the presented algorithm.The measurements and analysis for this study were conducted at the Sarcheshmeh Copper Concentrator Plant located in Iran.The quality of the obtained results was very satisfied;so that the RMS errors of prediction obtained for Cu and Mo grade assaying errors in rougher feed were less than 0.039 and 0.002 and in final flotation concentration less than 0.58 and 0.074,respectively.The results indicate that the mentioned method is quite accurate to reduce the on-line XRF errors measurement.