The fabrication of a new type of one-dimensional Au-Ag porous nanotube(NPT) structure was presented based on a facile combination of nanocrystal growth and surface modification.Ag nanowires with various diameters we...The fabrication of a new type of one-dimensional Au-Ag porous nanotube(NPT) structure was presented based on a facile combination of nanocrystal growth and surface modification.Ag nanowires with various diameters were firstly served as the chemical plating templates via a polyol-process.Then,one-dimensional(1D) Au-Ag porous nanostructures with tailored structural features could be prepared by controlling the individual steps involved in this process,such as nanowire growth,surface modification,thermal diffusion,and dealloying.Structural characterizations reveal these Au-Ag porous nanotubes,non-porous nanotubes and porous nanowires possess novel nano-architectures with multimodal open porosity and excellent structural continuity and integrity,which make them particularly desirable as novel 1D nanocarriers for biomedical,drug delivery and sensing applications.展开更多
Aiming at understanding how intermetallic phases response when AA2024-T3 aluminium alloy is exposed to chloridecontainingaqueous medium, scanning electron microscopy was employed to provide morphological information o...Aiming at understanding how intermetallic phases response when AA2024-T3 aluminium alloy is exposed to chloridecontainingaqueous medium, scanning electron microscopy was employed to provide morphological information on alloy surfacebefore and after corrosion testing. Energy dispersive X-ray spectroscopy was carried out to determine compositional change inintermetallic particles. Atomic force microscopy was used to examine topographical variation introduced by the reactions ofintermetallic phases. Transmission electron microscopy combined with ultramicrotomy was carried out on dealloyed Al2CuMgparticles and their periphery region. It is found that dealloyed Al2CuMg particles exhibited porous, polycrystalline structurecomprised of body-centred cubic copper particles with sizes of 5 to 20 nm. Aluminium matrix started to trench in the periphery ofAl2CuMg particles at the early stage of dealloying. Development of trenching in Al.Cu.Fe.Mn.(Si) particle’s periphery was notuniform and took longer time to initiate than Al2CuMg dealloying. Localized corrosion at a cluster of Al2CuMg and Al2Cu particleswas mainly associated with Al2CuMg particles.展开更多
This research aims to extract Cu from Cu-Co alloy with high efficiency and selectivity by employing binary Mg-Pb melt. The optimal conditions for the extraction of Cu were determined. The results showed under optimal ...This research aims to extract Cu from Cu-Co alloy with high efficiency and selectivity by employing binary Mg-Pb melt. The optimal conditions for the extraction of Cu were determined. The results showed under optimal conditions, 96.5% of Cu in the Cu-Co alloy could be selectively extracted after treatment at 800 ℃ for 1 h, with the extraction rates of only 0.2% Fe, 0.6% Co, and 1.4% Si. The dissolution mechanism involved the counter diffusion of Mg/Pb and Cu across the diffusion zone of the Cu-Co alloy, and Mg in the binary Mg-Pb melt played a major role in the selective dissolution of Cu, especially at the dissolution forefront. The rate-controlling step of the extraction was dominated by the interfacial reaction.展开更多
The wire electrical discharge machining(EDM) of 6061 aluminium alloy in terms of material removal rate,kerf/slit width,surface finish and wear of electrode wire for different pulse on time and wire tension was studi...The wire electrical discharge machining(EDM) of 6061 aluminium alloy in terms of material removal rate,kerf/slit width,surface finish and wear of electrode wire for different pulse on time and wire tension was studied.Eight experiments were carried out in a wire EDM machine by varying pulse on time and wire tension.It is found that the material removal rate increases with the increase of pulse on time though the wire tension does not affect the material removal rate.It seems that the higher wire tension facilitates steady machining process,which generates low wear in wire electrode and better surface finish.The surface roughness does not change notably with the variation of pulse on time.The appearance of the machined surfaces is very similar under all the machining conditions.The machined surface contains solidified molten material,splash of materials and blisters.The increase of the pulse on time increases the wear of wire electrode due to the increase of heat input.The wear of wire electrode generates tapered slot which has higher kerf width at top side than that at bottom side.The higher electrode wear introduces higher taper.展开更多
基金Project (2012CB932800) supported by the National Basic Research Program of ChinaProject (2012M521330) supported by China Postdoctoral Science Foundation
文摘The fabrication of a new type of one-dimensional Au-Ag porous nanotube(NPT) structure was presented based on a facile combination of nanocrystal growth and surface modification.Ag nanowires with various diameters were firstly served as the chemical plating templates via a polyol-process.Then,one-dimensional(1D) Au-Ag porous nanostructures with tailored structural features could be prepared by controlling the individual steps involved in this process,such as nanowire growth,surface modification,thermal diffusion,and dealloying.Structural characterizations reveal these Au-Ag porous nanotubes,non-porous nanotubes and porous nanowires possess novel nano-architectures with multimodal open porosity and excellent structural continuity and integrity,which make them particularly desirable as novel 1D nanocarriers for biomedical,drug delivery and sensing applications.
基金Project(51201157)supported by the National Natural Science Foundation of ChinaProject(H052013A003)supported by the National Defense Technology Foundation,ChinaProject supported by the UK-ESPRC LATEST2 Program
文摘Aiming at understanding how intermetallic phases response when AA2024-T3 aluminium alloy is exposed to chloridecontainingaqueous medium, scanning electron microscopy was employed to provide morphological information on alloy surfacebefore and after corrosion testing. Energy dispersive X-ray spectroscopy was carried out to determine compositional change inintermetallic particles. Atomic force microscopy was used to examine topographical variation introduced by the reactions ofintermetallic phases. Transmission electron microscopy combined with ultramicrotomy was carried out on dealloyed Al2CuMgparticles and their periphery region. It is found that dealloyed Al2CuMg particles exhibited porous, polycrystalline structurecomprised of body-centred cubic copper particles with sizes of 5 to 20 nm. Aluminium matrix started to trench in the periphery ofAl2CuMg particles at the early stage of dealloying. Development of trenching in Al.Cu.Fe.Mn.(Si) particle’s periphery was notuniform and took longer time to initiate than Al2CuMg dealloying. Localized corrosion at a cluster of Al2CuMg and Al2Cu particleswas mainly associated with Al2CuMg particles.
基金funded by the National Natural Science Foundation of China(Nos.51904350,51874371)the Hunan Natural Science Foundation,China(No.2021JJ30854).
文摘This research aims to extract Cu from Cu-Co alloy with high efficiency and selectivity by employing binary Mg-Pb melt. The optimal conditions for the extraction of Cu were determined. The results showed under optimal conditions, 96.5% of Cu in the Cu-Co alloy could be selectively extracted after treatment at 800 ℃ for 1 h, with the extraction rates of only 0.2% Fe, 0.6% Co, and 1.4% Si. The dissolution mechanism involved the counter diffusion of Mg/Pb and Cu across the diffusion zone of the Cu-Co alloy, and Mg in the binary Mg-Pb melt played a major role in the selective dissolution of Cu, especially at the dissolution forefront. The rate-controlling step of the extraction was dominated by the interfacial reaction.
文摘The wire electrical discharge machining(EDM) of 6061 aluminium alloy in terms of material removal rate,kerf/slit width,surface finish and wear of electrode wire for different pulse on time and wire tension was studied.Eight experiments were carried out in a wire EDM machine by varying pulse on time and wire tension.It is found that the material removal rate increases with the increase of pulse on time though the wire tension does not affect the material removal rate.It seems that the higher wire tension facilitates steady machining process,which generates low wear in wire electrode and better surface finish.The surface roughness does not change notably with the variation of pulse on time.The appearance of the machined surfaces is very similar under all the machining conditions.The machined surface contains solidified molten material,splash of materials and blisters.The increase of the pulse on time increases the wear of wire electrode due to the increase of heat input.The wear of wire electrode generates tapered slot which has higher kerf width at top side than that at bottom side.The higher electrode wear introduces higher taper.