For physical ozone absorption without reaction,two parametric estimation methods,i.e.the common linear least square fitting and non-linear Simplex search methods,were applied,respectively,to determine the ozone mass t...For physical ozone absorption without reaction,two parametric estimation methods,i.e.the common linear least square fitting and non-linear Simplex search methods,were applied,respectively,to determine the ozone mass transfer coefficient during absorption and both methods give almost the same mass transfer coefficient.While for chemical absorption with ozone decomposition reaction,the common linear least square fitting method is not applicable for the evaluation of ozone mass transfer coefficient due to the difficulty of model linearization for describing ozone concentration dissolved in water.The nonlinear Simplex method obtains the mass transfer coefficient by minimizing the sum of the differences between the simulated and experimental ozone concentration during the whole absorption process,without the limitation of linear relationship between the dissolved ozone concentration and absorption time during the initial stage of absorption.Comparison of the ozone concentration profiles between the simulation and experimental data demonstrates that Simplex method may determine ozone mass transfer coefficient during absorption in an accurate and high efficiency way with wide applicability.展开更多
Power systems are the largest and most complex human made systems, consisting of thousands of electrical sources, loads, transmission and distribution lines, power transformers, circuit breakers, etc. where faults alw...Power systems are the largest and most complex human made systems, consisting of thousands of electrical sources, loads, transmission and distribution lines, power transformers, circuit breakers, etc. where faults always occurred. Faults can cause personnel and equipment safety problems, and can result in significant disruption to power supply and thus financial losses. In this paper we will present comprehensive mathematical suite to detect and classify fault dependent models of various types of power systems. This work will extract fault unique signatures by using polarization ellipse during the healthy condition and the polarization will be circular shape with radius equal the rated voltage of the system, but during the fault condition the polarization will be ellipse shape and the fault signature will be defined according the ellipse parameters major axis, minor axis, ellipticity and orientation angle, by using least squares criterion will define the ellipse parameters this system will identify and classify. This paper will be a milestone for extended paper based on the proposed mathematical modelling and applying it to identify, classify and localize with simulation model.展开更多
基金Project(2011467001)supported by the Ministry of Environment Protection of ChinaProject(2010DFB94130)supported by the Ministry of Science and Technology of China
文摘For physical ozone absorption without reaction,two parametric estimation methods,i.e.the common linear least square fitting and non-linear Simplex search methods,were applied,respectively,to determine the ozone mass transfer coefficient during absorption and both methods give almost the same mass transfer coefficient.While for chemical absorption with ozone decomposition reaction,the common linear least square fitting method is not applicable for the evaluation of ozone mass transfer coefficient due to the difficulty of model linearization for describing ozone concentration dissolved in water.The nonlinear Simplex method obtains the mass transfer coefficient by minimizing the sum of the differences between the simulated and experimental ozone concentration during the whole absorption process,without the limitation of linear relationship between the dissolved ozone concentration and absorption time during the initial stage of absorption.Comparison of the ozone concentration profiles between the simulation and experimental data demonstrates that Simplex method may determine ozone mass transfer coefficient during absorption in an accurate and high efficiency way with wide applicability.
文摘Power systems are the largest and most complex human made systems, consisting of thousands of electrical sources, loads, transmission and distribution lines, power transformers, circuit breakers, etc. where faults always occurred. Faults can cause personnel and equipment safety problems, and can result in significant disruption to power supply and thus financial losses. In this paper we will present comprehensive mathematical suite to detect and classify fault dependent models of various types of power systems. This work will extract fault unique signatures by using polarization ellipse during the healthy condition and the polarization will be circular shape with radius equal the rated voltage of the system, but during the fault condition the polarization will be ellipse shape and the fault signature will be defined according the ellipse parameters major axis, minor axis, ellipticity and orientation angle, by using least squares criterion will define the ellipse parameters this system will identify and classify. This paper will be a milestone for extended paper based on the proposed mathematical modelling and applying it to identify, classify and localize with simulation model.