By properly selecting the time-dependent unitary transformation for the linear combination of the number operators, we construct a time-dependent invariant and derive the corresponding auxiliary equations for the dege...By properly selecting the time-dependent unitary transformation for the linear combination of the number operators, we construct a time-dependent invariant and derive the corresponding auxiliary equations for the degenerate and non-degenerate coupled parametric down-conversion system with driving term. By means of this invariant and the Lewis-Riesenfeld quantum invariant theory, we obtain closed formulae of the quantum state and the evolution operator of the system. We show that the time evolution of the quantum system directly leads to production of various generalized one- and two-mode combination squeezed states, and the squeezed effect is independent of the driving term of the Hamiltonian. In some special cases, the current solution can reduce to the results of the previous works.展开更多
In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study des...In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.展开更多
This paper reports the experimental and theoretical study of the surge occurred in prototyping an ultra micro centrifugal compressor. As the first step, the 10 times size model of an ultra micro centrifugal compressor...This paper reports the experimental and theoretical study of the surge occurred in prototyping an ultra micro centrifugal compressor. As the first step, the 10 times size model of an ultra micro centrifugal compressor having the 40 mm outer diameter was designed and manufactured. The detailed experimental investigations for the transient behavior of surge with several different values of B parameter were carded out. The experimental results during the surge were compared with those obtained by the non-linear lumped parameter theory in order to validate the effectiveness of the theoretical surge model for the micro centrifugal compressor. As a result, the quite different behavior of the surge appeared for the different values of B both in the experiment and in the analysis.展开更多
基金supported by the National Natural Science Foundation of China under Grant Nos.40674076 and 40474064the Hunan Natural Science Foundation of China under Grant No.07JJ3123the Scientific Research Fund of Hunan Provincial Education Department under Grant Nos.06C163,05B023,and 06B004
文摘By properly selecting the time-dependent unitary transformation for the linear combination of the number operators, we construct a time-dependent invariant and derive the corresponding auxiliary equations for the degenerate and non-degenerate coupled parametric down-conversion system with driving term. By means of this invariant and the Lewis-Riesenfeld quantum invariant theory, we obtain closed formulae of the quantum state and the evolution operator of the system. We show that the time evolution of the quantum system directly leads to production of various generalized one- and two-mode combination squeezed states, and the squeezed effect is independent of the driving term of the Hamiltonian. In some special cases, the current solution can reduce to the results of the previous works.
文摘In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.
文摘This paper reports the experimental and theoretical study of the surge occurred in prototyping an ultra micro centrifugal compressor. As the first step, the 10 times size model of an ultra micro centrifugal compressor having the 40 mm outer diameter was designed and manufactured. The detailed experimental investigations for the transient behavior of surge with several different values of B parameter were carded out. The experimental results during the surge were compared with those obtained by the non-linear lumped parameter theory in order to validate the effectiveness of the theoretical surge model for the micro centrifugal compressor. As a result, the quite different behavior of the surge appeared for the different values of B both in the experiment and in the analysis.