Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impeda...Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impedance andthe fault resistance.The distributed parameter model and the modal transformationare also employed.Depending on modal transformation,the coupled equations of the lines are converted intodecoupled ones.Inthis way,the mutual coupling effects between adjacent circuits of the lines are eliminatedandtherefore an accurate fault location can be achieved.The proposed methodis tested via digital simulationusing EMTP in conjunction with MATLAB.The test results corroborate the high accuracy of the proposedmethod.展开更多
The strength of the power frequency electric intensity and magnetic field of the 500-kV double circuit transmission lines was calculated by using the equivalent charge method and the Ampere's Law, and the environm...The strength of the power frequency electric intensity and magnetic field of the 500-kV double circuit transmission lines was calculated by using the equivalent charge method and the Ampere's Law, and the environmental impact factors of the fields were evaluated. By optimizing the phase sequence, the frequency electric intensity and magnetic field strength can be reduced. Within a distance of 25 m from the center of the transmission line, the power frequency electric intensity and magnetic field strength fall off sharply with the distance increase. Finally, the best phase sequence and the minimum ground clearance of the transmission lines were obtained to meet the requirements of the least impact on envionment.展开更多
文摘Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impedance andthe fault resistance.The distributed parameter model and the modal transformationare also employed.Depending on modal transformation,the coupled equations of the lines are converted intodecoupled ones.Inthis way,the mutual coupling effects between adjacent circuits of the lines are eliminatedandtherefore an accurate fault location can be achieved.The proposed methodis tested via digital simulationusing EMTP in conjunction with MATLAB.The test results corroborate the high accuracy of the proposedmethod.
文摘The strength of the power frequency electric intensity and magnetic field of the 500-kV double circuit transmission lines was calculated by using the equivalent charge method and the Ampere's Law, and the environmental impact factors of the fields were evaluated. By optimizing the phase sequence, the frequency electric intensity and magnetic field strength can be reduced. Within a distance of 25 m from the center of the transmission line, the power frequency electric intensity and magnetic field strength fall off sharply with the distance increase. Finally, the best phase sequence and the minimum ground clearance of the transmission lines were obtained to meet the requirements of the least impact on envionment.