Objective To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral fliPS) mode for coronary stents patency. Methods We conducted a prospective study on 120 patients with 260 ...Objective To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral fliPS) mode for coronary stents patency. Methods We conducted a prospective study on 120 patients with 260 previous stents implanted due to recurred suspicious symptoms of angina scheduled for invasive coronary angiography (ICA), while DSCT were conducted using HPS mode. Results There was no significant impact of age, body mass index or heat rate (HR) on image quality (P 〉 0.05), while HR variability had a slight impact on that (P 〈 0.05). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of DSCT in detection of in-stent restenosis (ISR) based per-patient were 92.3%, 96.7%, 88.9%, and 97.8%, respectively. And those based per-stent were 87%, 96.8%, 83.3%, and 97.7% with un-assessment stents, 97.4%, 99.5%, 97.4%, and 99.5% without un-assessment stents. There was significant differ- ence on sensitivity, specificity, PPV and NPV between diameter 〉 3.0 mm group (93.3%, 97.9%, 87.5%, and 98.9%) and diameter 〈 3.0 mm group (80%, 93.3%, 80.0%, and 93.3%) (P 〈 0.05), and that between stent number 〉 3 group (82.3%, 77.8%, 66.7%, and 60%) with 〈 3 group (97.3%, 80%, 96.5%, and 75%). The effective dose of DSCT (1.4 ± 0.5 mSv) is significantly less than that by invasive coronary angiography [4.0 ± 0.8 mSv (P 〈 0.01)]. Conclusion DSCT using HPS mode provides good diagnostic performance on stent patency with lower effective dose in patients with HR 〈 65 beats/rain.展开更多
Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona...Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.展开更多
A 1 kbit antifuse one time programmable(OTP) memory IP,which is one of the non-volatile memory IPs,was designed and used for power management integrated circuits(ICs).A conventional antifuse OTP cell using a single po...A 1 kbit antifuse one time programmable(OTP) memory IP,which is one of the non-volatile memory IPs,was designed and used for power management integrated circuits(ICs).A conventional antifuse OTP cell using a single positive program voltage(VPP) has a problem when applying a higher voltage than the breakdown voltage of the thin gate oxides and at the same time,securing the reliability of medium voltage(VM) devices that are thick gate transistors.A new antifuse OTP cell using a dual program voltage was proposed to prevent the possibility for failures in a qualification test or the yield drop.For the newly proposed cell,a stable sensing is secured from the post-program resistances of several ten thousand ohms or below due to the voltage higher than the hard breakdown voltage applied to the terminals of the antifuse.The layout size of the designed 1 kbit antifuse OTP memory IP with Dongbu HiTek's 0.18 μm Bipolar-CMOS-DMOS(BCD) process is 567.9 μm×205.135 μm and the post-program resistance of an antifuse is predicted to be several ten thousand ohms.展开更多
文摘Objective To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral fliPS) mode for coronary stents patency. Methods We conducted a prospective study on 120 patients with 260 previous stents implanted due to recurred suspicious symptoms of angina scheduled for invasive coronary angiography (ICA), while DSCT were conducted using HPS mode. Results There was no significant impact of age, body mass index or heat rate (HR) on image quality (P 〉 0.05), while HR variability had a slight impact on that (P 〈 0.05). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of DSCT in detection of in-stent restenosis (ISR) based per-patient were 92.3%, 96.7%, 88.9%, and 97.8%, respectively. And those based per-stent were 87%, 96.8%, 83.3%, and 97.7% with un-assessment stents, 97.4%, 99.5%, 97.4%, and 99.5% without un-assessment stents. There was significant differ- ence on sensitivity, specificity, PPV and NPV between diameter 〉 3.0 mm group (93.3%, 97.9%, 87.5%, and 98.9%) and diameter 〈 3.0 mm group (80%, 93.3%, 80.0%, and 93.3%) (P 〈 0.05), and that between stent number 〉 3 group (82.3%, 77.8%, 66.7%, and 60%) with 〈 3 group (97.3%, 80%, 96.5%, and 75%). The effective dose of DSCT (1.4 ± 0.5 mSv) is significantly less than that by invasive coronary angiography [4.0 ± 0.8 mSv (P 〈 0.01)]. Conclusion DSCT using HPS mode provides good diagnostic performance on stent patency with lower effective dose in patients with HR 〈 65 beats/rain.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.
基金Work supported by the Second Stage of Brain Korea 21 Projectssupported by Changwon National University in 2009-2010
文摘A 1 kbit antifuse one time programmable(OTP) memory IP,which is one of the non-volatile memory IPs,was designed and used for power management integrated circuits(ICs).A conventional antifuse OTP cell using a single positive program voltage(VPP) has a problem when applying a higher voltage than the breakdown voltage of the thin gate oxides and at the same time,securing the reliability of medium voltage(VM) devices that are thick gate transistors.A new antifuse OTP cell using a dual program voltage was proposed to prevent the possibility for failures in a qualification test or the yield drop.For the newly proposed cell,a stable sensing is secured from the post-program resistances of several ten thousand ohms or below due to the voltage higher than the hard breakdown voltage applied to the terminals of the antifuse.The layout size of the designed 1 kbit antifuse OTP memory IP with Dongbu HiTek's 0.18 μm Bipolar-CMOS-DMOS(BCD) process is 567.9 μm×205.135 μm and the post-program resistance of an antifuse is predicted to be several ten thousand ohms.