This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control ...This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results.展开更多
The power of the toroidal field (TF) coil in HL-2A is supplied with two 80 MVA motor generators (MGs) together through a diode rectifier. The TF system is designed to obtain the parameters as follows: the highest...The power of the toroidal field (TF) coil in HL-2A is supplied with two 80 MVA motor generators (MGs) together through a diode rectifier. The TF system is designed to obtain the parameters as follows: the highest toroidal filed of 2.8 T, the biggest coil current of 45 kA, the fiat top time of 3-5 s. So the released energy of each MG set for one pulse discharge mast be more than 500 MJ.展开更多
基金Project (No. 50577056) supported by the National Natural ScienceFoundation of China
文摘This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results.
文摘The power of the toroidal field (TF) coil in HL-2A is supplied with two 80 MVA motor generators (MGs) together through a diode rectifier. The TF system is designed to obtain the parameters as follows: the highest toroidal filed of 2.8 T, the biggest coil current of 45 kA, the fiat top time of 3-5 s. So the released energy of each MG set for one pulse discharge mast be more than 500 MJ.