期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
大流量双主动双电反馈电液比例插装式节流阀研制与开发 被引量:8
1
作者 于良振 王明琳 方锦辉 《机床与液压》 北大核心 2010年第2期46-47,82,共3页
大流量双主动双电反馈电液比例插装式节流阀具有流量大、频响高等特点。介绍了该阀的研发过程,分析了该阀的设计要求,通过AMESim对该阀进行了建模与仿真分析,在此基础上设计并试制了样机,通过试验验证,该阀的各项性能指标均达到设计要求。
关键词 电液比例插装阀 双电反馈 双主动
下载PDF
大流量双主动双电反馈电液比例插装式节流阀简介
2
作者 于良振 王明琳 《流体传动与控制》 2010年第1期54-55,共2页
文章介绍了大流量双主动双电反馈电液比例插装式节流阀的国内外研究现状、主要研究内容和主要的技术创新点。
关键词 电液比例插装阀 双电反馈 双主动
下载PDF
Enhanced control of DFIG-used back-to-back PWM VSC under unbalanced grid voltage conditions 被引量:20
3
作者 HU Jia-bing HE Yi-kang NIAN Heng 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第8期1330-1339,共10页
This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control ... This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results. 展开更多
关键词 Unbalanced grid voltage Doubly-fed induction generator (DFIG) Back-to-back (BTB) Fault-ride through (FRT) Voltage source converter (VSC)
下载PDF
Development of Super-Synchronization Speed Control Assembly in Two 80 MVA Motor Generators of HL-2A Tokamak
4
作者 LI Huajun DU Chang +9 位作者 XUAN Weimin PEN Jianfei HU Haotian LIU Lin KANG Li XU Lirong HUANG Zhaorong WANG Fen WANG Xiaoping WANG Haibing 《Southwestern Institute of Physics Annual Report》 2005年第1期71-73,共3页
The power of the toroidal field (TF) coil in HL-2A is supplied with two 80 MVA motor generators (MGs) together through a diode rectifier. The TF system is designed to obtain the parameters as follows: the highest... The power of the toroidal field (TF) coil in HL-2A is supplied with two 80 MVA motor generators (MGs) together through a diode rectifier. The TF system is designed to obtain the parameters as follows: the highest toroidal filed of 2.8 T, the biggest coil current of 45 kA, the fiat top time of 3-5 s. So the released energy of each MG set for one pulse discharge mast be more than 500 MJ. 展开更多
关键词 Double fed drive motor AC-AC cycloconverte Vector control
下载PDF
上一页 1 下一页 到第