Volumetric fraction distribution measurement is a constituent part of process tomography system in oil-water-gas multiphase flow. With the technological development of nuclear radial inspection, dual-energy γ-ray tec...Volumetric fraction distribution measurement is a constituent part of process tomography system in oil-water-gas multiphase flow. With the technological development of nuclear radial inspection, dual-energy γ-ray techniques make it possible to investigate the concentration of the different components on the cross-section of oil-water-gas multiphase pipe-flow. The dual-energy gamma-ray technique is based on materials attenuation coefficients measurement comprised of two radioactive isotopes of 241Am and 241Cs which have emission energies at 59.5 keV and 662 keV in this project. Nuclear instruments and data acquisition system were designed to measure the material’s attenuation dose rate and a number of static tests were conducted at the Multiphase Laboratory, Institute of Mechanics, Chinese Academy of Sciences. Three phases of oil-water-gas media were inves- tigated for their possible use to simulate different media volumetric fraction distributions in experimental vessels. Attenuation intensities were measured, and the arithmetic of linear attenuation coefficients and the equations of volumetric fractions were studied. Investigation of an unexpected measurement error from attenuation equations revealed that a modified arithmetic was involved and finally the system achieved acceptable accuracy in experimental research.展开更多
文摘Volumetric fraction distribution measurement is a constituent part of process tomography system in oil-water-gas multiphase flow. With the technological development of nuclear radial inspection, dual-energy γ-ray techniques make it possible to investigate the concentration of the different components on the cross-section of oil-water-gas multiphase pipe-flow. The dual-energy gamma-ray technique is based on materials attenuation coefficients measurement comprised of two radioactive isotopes of 241Am and 241Cs which have emission energies at 59.5 keV and 662 keV in this project. Nuclear instruments and data acquisition system were designed to measure the material’s attenuation dose rate and a number of static tests were conducted at the Multiphase Laboratory, Institute of Mechanics, Chinese Academy of Sciences. Three phases of oil-water-gas media were inves- tigated for their possible use to simulate different media volumetric fraction distributions in experimental vessels. Attenuation intensities were measured, and the arithmetic of linear attenuation coefficients and the equations of volumetric fractions were studied. Investigation of an unexpected measurement error from attenuation equations revealed that a modified arithmetic was involved and finally the system achieved acceptable accuracy in experimental research.