Filtering-efficiency measurement of Chinese-made filter 1by double-filter method
1
作者 ZHI Min (Shanghai Institute of Nuclear Rcsearrh, the Chinese Academy of Sciences, Shanghai 201800) 《Nuclear Science and Techniques》 SCIE CAS CSCD 1999年第3期168-170,共3页
Filtering efficiency of the Chinese-made filter 1 has been measured by the double-filter method with only one set of measurement equipment. The β counts of the two filters are measured in turn for every 3 minutes, fr... Filtering efficiency of the Chinese-made filter 1 has been measured by the double-filter method with only one set of measurement equipment. The β counts of the two filters are measured in turn for every 3 minutes, from which the decay constants are extracted to be 0.0131 min-1 and 0.0129 min-1 for the first and second filter respectively. After correcting the β counts of the second filter, the filtering efficiency of the filter is obtained to be (87.4±0.7)% in average. 展开更多
关键词 滤波 双重滤波方法 滤波效率