Dissociative adsorption of HCl on Au(111)has become one of unsolved puzzles in surface chemistry.Despite tremendous efforts in the past years,varioustheoretical models still greatly overestimate the zero-coverage init...Dissociative adsorption of HCl on Au(111)has become one of unsolved puzzles in surface chemistry.Despite tremendous efforts in the past years,varioustheoretical models still greatly overestimate the zero-coverage initial sticking probabilities(So).To find the origin of the large experiment-theory discrepancy,we have revisited the dissociative adsorption of HCl on Au(111)with a newly designed molecular beam-surface apparatus.The zero-coverage So derived from Cl-coverage measurements with varying HCl doses agree well with previous ones.However,we notice a sharp change of the coverage/dose slope with the HCl dosage at the low coverage regime,which may result in some uncertainties to the fitted So value.This seems consistent with a coverage-dependence of the dissociation barrier predicted by density functional theory at low Cl-coverages.Our results reveal the potential inconsistency of utilizing simulations with finite coverage to compare against experimental data with zero coverage in this system,and provide guidance for improving both experiment and theory in this regard.展开更多
The reverse flotation separation performance and mechanism of hematite and cellophane in the presence of RFP-138, a newly synthesized dephosphorization collector, were studied. Reverse flotation tests on monominerals ...The reverse flotation separation performance and mechanism of hematite and cellophane in the presence of RFP-138, a newly synthesized dephosphorization collector, were studied. Reverse flotation tests on monominerals and artificially mixed minerals of hematite and collophanite show that, this anionic collector performs excellently in reducing the phosphorus content in hematite. It can decrease the content of P in artificially mixed minerals from 1.05% to 0.12% and achieve the TFe recovery rate of 91.30%. The chemical behavior of solution and infrared spectra of RFP-138 were investigated to explore the selective collecting mechanism of RFP-138 to these two minerals.展开更多
A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filte...A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized.展开更多
基金supported by the National Natural Science Foundation of China(No.22173042,No.21973037,No.22073089,and No.22327801)the In-novation program for Quantum Science and Technolo-gy(No.2021ZD0303304)+2 种基金the Guangdong Science and Technology Program(No.2019ZT08L455 and No.2019JC01X091)the Shenzhen Science and Technology Program(No.ZDSYS2020421111001787)Strategic Priority Research Program of the Chinese Academy of Sciences(XDB0450101).
文摘Dissociative adsorption of HCl on Au(111)has become one of unsolved puzzles in surface chemistry.Despite tremendous efforts in the past years,varioustheoretical models still greatly overestimate the zero-coverage initial sticking probabilities(So).To find the origin of the large experiment-theory discrepancy,we have revisited the dissociative adsorption of HCl on Au(111)with a newly designed molecular beam-surface apparatus.The zero-coverage So derived from Cl-coverage measurements with varying HCl doses agree well with previous ones.However,we notice a sharp change of the coverage/dose slope with the HCl dosage at the low coverage regime,which may result in some uncertainties to the fitted So value.This seems consistent with a coverage-dependence of the dissociation barrier predicted by density functional theory at low Cl-coverages.Our results reveal the potential inconsistency of utilizing simulations with finite coverage to compare against experimental data with zero coverage in this system,and provide guidance for improving both experiment and theory in this regard.
基金Project (2010FJ3069) supported by Science and Technology Project of Hunan Province, China
文摘The reverse flotation separation performance and mechanism of hematite and cellophane in the presence of RFP-138, a newly synthesized dephosphorization collector, were studied. Reverse flotation tests on monominerals and artificially mixed minerals of hematite and collophanite show that, this anionic collector performs excellently in reducing the phosphorus content in hematite. It can decrease the content of P in artificially mixed minerals from 1.05% to 0.12% and achieve the TFe recovery rate of 91.30%. The chemical behavior of solution and infrared spectra of RFP-138 were investigated to explore the selective collecting mechanism of RFP-138 to these two minerals.
文摘A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized.