Scaling of reverse osmosis (RO) membrane surface is one of the main problems in desalination proc- esses. To mitigate scales, organic anti-scalants are often used. If the dosages of anti-scalants are reduced, by using...Scaling of reverse osmosis (RO) membrane surface is one of the main problems in desalination proc- esses. To mitigate scales, organic anti-scalants are often used. If the dosages of anti-scalants are reduced, by using other much cheaper scale inhibitors, RO running cost will decrease greatly. The present paper investigated the inhi- bition of CaCO3 precipitation by zinc ions in RO system. The results show that the zinc ion concentration of 2mg?L-1 was able to exert a marked suppression effect on both bulk precipitation of CaCO3 and on membrane scaling on waters of moderate hardness.展开更多
基金Supported by the National Natural Science Foundation of China (No.20306015) and the Scientific Research Foundation of theState Education Ministry for Returned Overseas Chinese Scholars (No.[2003]406).
文摘Scaling of reverse osmosis (RO) membrane surface is one of the main problems in desalination proc- esses. To mitigate scales, organic anti-scalants are often used. If the dosages of anti-scalants are reduced, by using other much cheaper scale inhibitors, RO running cost will decrease greatly. The present paper investigated the inhi- bition of CaCO3 precipitation by zinc ions in RO system. The results show that the zinc ion concentration of 2mg?L-1 was able to exert a marked suppression effect on both bulk precipitation of CaCO3 and on membrane scaling on waters of moderate hardness.