Simultaneous prestack inversion is based on the modified Fatti equation and uses the ratio of the P- and S-wave velocity as constraints. We use the relation of P-wave impedance and density (PID) and S-wave impedance...Simultaneous prestack inversion is based on the modified Fatti equation and uses the ratio of the P- and S-wave velocity as constraints. We use the relation of P-wave impedance and density (PID) and S-wave impedance and density (SID) to replace the constant Vp/Vs constraint, and we propose the improved constrained Fatti equation to overcome the effect of P-wave impedance on density. We compare the sensitivity of both methods using numerical simulations and conclude that the density inversion sensitivity improves when using the proposed method. In addition, the random conjugate-gradient method is used in the inversion because it is fast and produces global solutions. The use of synthetic and field data suggests that the proposed inversion method is effective in conventional and nonconventional lithologies.展开更多
Azimuthal electromagnetic(EM)logging while drilling(LWD)has been extensively used in high-angle and horizontal(HA/HZ)wells.However,due to the effects of formation anisotropy,accurate geosteering decision and formation...Azimuthal electromagnetic(EM)logging while drilling(LWD)has been extensively used in high-angle and horizontal(HA/HZ)wells.However,due to the effects of formation anisotropy,accurate geosteering decision and formation evaluations have become increasingly difficult.To quantitatively analyze the effect of anisotropy on tool responses and data processing,this paper investigates the sensitivity of EM LWD measurements to electric anisotropy and inversion accuracy via forward modeling and inversion.First,a sensitivity factor is defined to quantitatively analyze the sensitivity of the magnetic field components and synthetic signals to electric anisotropy.Then,azimuthal EM LWD responses in anisotropic layered formations are simulated,and the sensitivities to formation parameters for compensated and uncompensated tool configurations are comparatively analyzed.Finally,we discuss the effects of the inversion model on bed boundary inversion in anisotropic formations.Numerical simulation and inversion results show that azimuthal EM LWD can be significantly affected by electric anisotropy.Fortunately,by using a symmetrical compensation configuration,the sensitivity of the geosignals to electric anisotropy can be suppressed,and the boundary detection capability can be further enhanced.Anisotropy normally gives rise to separated resistivity curves and abnormal"horns";moreover,complicated nonlinear distortion can also arise in geosignals as the tool approaches a bed boundary.If anisotropy effects are ignored in the inversion process,the estimated bed boundary and formation resistivity are usually unreliable,which may mislead geosteering decisions.展开更多
基金supported by the National Nature Science Foundation of China(Nos.41374116 and 41674113)the project of CNOOC(No.CNOOC-KJ 125 ZDXM 07 LTD NFGC 2014-04)
文摘Simultaneous prestack inversion is based on the modified Fatti equation and uses the ratio of the P- and S-wave velocity as constraints. We use the relation of P-wave impedance and density (PID) and S-wave impedance and density (SID) to replace the constant Vp/Vs constraint, and we propose the improved constrained Fatti equation to overcome the effect of P-wave impedance on density. We compare the sensitivity of both methods using numerical simulations and conclude that the density inversion sensitivity improves when using the proposed method. In addition, the random conjugate-gradient method is used in the inversion because it is fast and produces global solutions. The use of synthetic and field data suggests that the proposed inversion method is effective in conventional and nonconventional lithologies.
基金supported by the National Natural Science Foundation of China(No.41674131,No.41974146,and No.41904109)the Shandong Province Postdoctoral Innovation Projects(sdbh20180025)the Fundamental Research Funds for the Central Universities(No.17CX06041)。
文摘Azimuthal electromagnetic(EM)logging while drilling(LWD)has been extensively used in high-angle and horizontal(HA/HZ)wells.However,due to the effects of formation anisotropy,accurate geosteering decision and formation evaluations have become increasingly difficult.To quantitatively analyze the effect of anisotropy on tool responses and data processing,this paper investigates the sensitivity of EM LWD measurements to electric anisotropy and inversion accuracy via forward modeling and inversion.First,a sensitivity factor is defined to quantitatively analyze the sensitivity of the magnetic field components and synthetic signals to electric anisotropy.Then,azimuthal EM LWD responses in anisotropic layered formations are simulated,and the sensitivities to formation parameters for compensated and uncompensated tool configurations are comparatively analyzed.Finally,we discuss the effects of the inversion model on bed boundary inversion in anisotropic formations.Numerical simulation and inversion results show that azimuthal EM LWD can be significantly affected by electric anisotropy.Fortunately,by using a symmetrical compensation configuration,the sensitivity of the geosignals to electric anisotropy can be suppressed,and the boundary detection capability can be further enhanced.Anisotropy normally gives rise to separated resistivity curves and abnormal"horns";moreover,complicated nonlinear distortion can also arise in geosignals as the tool approaches a bed boundary.If anisotropy effects are ignored in the inversion process,the estimated bed boundary and formation resistivity are usually unreliable,which may mislead geosteering decisions.