Based on the methods of acquaintance cache and group-based intelligent forwarding of service recommendations,a novel group-based active service(GAS) protocol for migrating workflows was proposed.This protocol did not ...Based on the methods of acquaintance cache and group-based intelligent forwarding of service recommendations,a novel group-based active service(GAS) protocol for migrating workflows was proposed.This protocol did not require service requesters to discover services or resources.The semantic acquaintance knowledge representation was exploited to describe service groups and this semantic information was used to recommend service to respective clients.The experimental results show that the new protocol proposed offers better performance than other protocols in terms of first-response-time,success-scope and ratio of success-packet-number to total-packet-number.When the number of service request packet is 20,the first-response-time of GAS protocol is only 5.1 s,which is significantly lower than that of other protocols.The success-scope of GAS protocol is 49.1%,showing that GAS protocol can effectively improve the reliability of mobile transactions.And the ratio of success-packet-number to total-packet-number of GAS protocol is up to 0.080,which is obviously higher than that of other protocols.展开更多
Power quality is a complex term that is defined by the legislation, but also as an obligation of the supplier and customer. The customer must return the negative effects of its consumers (taking reactive power, harmo...Power quality is a complex term that is defined by the legislation, but also as an obligation of the supplier and customer. The customer must return the negative effects of its consumers (taking reactive power, harmonic generation, phase unbalance) down to the prescribed limits. This primarily refers to the presence of non-linear consumers, leading to distortion of the basic parameters of voltage and current, in steady or transient conditions, and therefore the deformation of waveform. One way to reduce the negative feedback effects, especially with inductive loads, is the reactive energy compensation. The paper presents one of the solution for reactive power compensation, applied on the pumping station of public company "Waterworks and Sewerage---Bar", Bar.展开更多
基金Project(60573169) supported by the National Natural Science Foundation of China
文摘Based on the methods of acquaintance cache and group-based intelligent forwarding of service recommendations,a novel group-based active service(GAS) protocol for migrating workflows was proposed.This protocol did not require service requesters to discover services or resources.The semantic acquaintance knowledge representation was exploited to describe service groups and this semantic information was used to recommend service to respective clients.The experimental results show that the new protocol proposed offers better performance than other protocols in terms of first-response-time,success-scope and ratio of success-packet-number to total-packet-number.When the number of service request packet is 20,the first-response-time of GAS protocol is only 5.1 s,which is significantly lower than that of other protocols.The success-scope of GAS protocol is 49.1%,showing that GAS protocol can effectively improve the reliability of mobile transactions.And the ratio of success-packet-number to total-packet-number of GAS protocol is up to 0.080,which is obviously higher than that of other protocols.
文摘Power quality is a complex term that is defined by the legislation, but also as an obligation of the supplier and customer. The customer must return the negative effects of its consumers (taking reactive power, harmonic generation, phase unbalance) down to the prescribed limits. This primarily refers to the presence of non-linear consumers, leading to distortion of the basic parameters of voltage and current, in steady or transient conditions, and therefore the deformation of waveform. One way to reduce the negative feedback effects, especially with inductive loads, is the reactive energy compensation. The paper presents one of the solution for reactive power compensation, applied on the pumping station of public company "Waterworks and Sewerage---Bar", Bar.