报道了用离子注入方法和组合技术制备的 Al Ga As/Ga As单量子阱多波长发光集成芯片 ,利用量子阱界面混合原理在同一块 Ga As衬底片上获得了 2 0多个发光波长从 787~ 72 4nm的 Ga As量子阱发光单元 ,研究了不同剂量的 As和 H离子分别...报道了用离子注入方法和组合技术制备的 Al Ga As/Ga As单量子阱多波长发光集成芯片 ,利用量子阱界面混合原理在同一块 Ga As衬底片上获得了 2 0多个发光波长从 787~ 72 4nm的 Ga As量子阱发光单元 ,研究了不同剂量的 As和 H离子分别单独注入和迭加组合注入对量子阱发光峰位的影响 ,采用了组合技术和离子注入技术大大简化了制备工艺过程 ,这种发光芯片对于波分复用器件和建立离子注入数据库等方面都有重要的意义 .展开更多
An on chip spiral channel flow cell for flow injection chemiluminescent system was prepared. Microchannels were fabricated using standard photolithography, wet chemical etching and thermal bonding techniques. Due to t...An on chip spiral channel flow cell for flow injection chemiluminescent system was prepared. Microchannels were fabricated using standard photolithography, wet chemical etching and thermal bonding techniques. Due to the long spiral channel on the chip and the oblate trapezoid cross section, there was enough time for the chemiluminescent reagents and sample to mix and react completely. The light produced can be easy to be recorded. The present on chip flow cell was used for the determination of some organic pollutants with peroxomonosulfate cobalt(Ⅱ)chemiluminescent system and mangnese(Ⅱ)with periodate carbonate chemiluminescent system. The detection limits for humic acid, 2 naphthol, benzo thiazole and mangnese(Ⅱ)are 3 0×10 -7 g·g -1 , 2 0×10 -6 mol·l -1 and 5 0×10 -7 mol·l -1 using peroxomonosulfate cobalt(Ⅱ)chemiluminescent system, and 5 0×10 -9 mol·l -1 using periodate carbo nate chemiluminescent system(S/N=3), respectively. The application of this flow cell to determine manganese(Ⅱ)in well water is also carried. The results are satisfactory.展开更多
介绍了一种基于FPGA的MDDI(mobile display digital interface)数据处理电路设计;基于单片集成AM-OLED驱动控制芯片的设计需求以及并行数据总线在移动显示设备上存在的不足,设计了MDDI数据处理电路;MDDI作为一种高速串行移动显示数字接...介绍了一种基于FPGA的MDDI(mobile display digital interface)数据处理电路设计;基于单片集成AM-OLED驱动控制芯片的设计需求以及并行数据总线在移动显示设备上存在的不足,设计了MDDI数据处理电路;MDDI作为一种高速串行移动显示数字接口标准,具有连线数量少,信号传输可靠性高,低功耗等特点,广泛应用于移动显示终端领域;所设计的MDDI Type2主端数据处理电路采用两级状态机控制内部电路,主状态机用于控制从状态机的状态切换,从状态机则用于实现MDDI数据的生成;通过加入可配置寄存器,实现对数据包生成和接口模式的控制;采用Verilog语言编写RTL级代码实现MDDI Type2数据处理电路软核;使用Xilinx工具综合的结果表明,该数据处理电路能够支持480-RGB×320、26万色的AM-OLED显示屏,数据传输速率可达180 Mbps,其性能指标满足系统设计要求。展开更多
文摘An on chip spiral channel flow cell for flow injection chemiluminescent system was prepared. Microchannels were fabricated using standard photolithography, wet chemical etching and thermal bonding techniques. Due to the long spiral channel on the chip and the oblate trapezoid cross section, there was enough time for the chemiluminescent reagents and sample to mix and react completely. The light produced can be easy to be recorded. The present on chip flow cell was used for the determination of some organic pollutants with peroxomonosulfate cobalt(Ⅱ)chemiluminescent system and mangnese(Ⅱ)with periodate carbonate chemiluminescent system. The detection limits for humic acid, 2 naphthol, benzo thiazole and mangnese(Ⅱ)are 3 0×10 -7 g·g -1 , 2 0×10 -6 mol·l -1 and 5 0×10 -7 mol·l -1 using peroxomonosulfate cobalt(Ⅱ)chemiluminescent system, and 5 0×10 -9 mol·l -1 using periodate carbo nate chemiluminescent system(S/N=3), respectively. The application of this flow cell to determine manganese(Ⅱ)in well water is also carried. The results are satisfactory.
文摘目的报道一种简单、快速、准确、敏感性强的化学发光蛋白芯片法,检测血清中的高尔基Ⅱ型跨膜蛋白73(GP73),有助于原发性肝癌的诊断。方法收集2017年3~9月首都医科大学附属北京佑安医院系信息管理中心美国癌症联合委员会(American Joint Committee on Cancer,AJCC)(第8版)分期Ⅰ期肝癌患者血清53份(实验组)和健康人血清47份(对照组),预先在醛基芯片上包被鼠源GP73单克隆抗体,建立GP73抗体蛋白芯片,然后用蛋白芯片方法进行检测,并以化学发光成像对检测结果进行判定,采用秩和检验进行统计学分析。结果实验组血清中GP73水平明显高于对照组,差异有统计学意义(P<0.01)。结论成功地建立了血清GP73的化学发光蛋白芯片检测方法,其应用将有助于原发性肝癌的诊断和高危人群的筛查。