The simple approach to acquire the fltaxescenee spectra of vitamin bl, b2 and t6 is proposed by direct ilhanination on solid powder sample. The experimentally acquired fluorescence spectra are in accordance with the p...The simple approach to acquire the fltaxescenee spectra of vitamin bl, b2 and t6 is proposed by direct ilhanination on solid powder sample. The experimentally acquired fluorescence spectra are in accordance with the previous measurements on soluble samples. The fluorescence spectra for a mixture of vitamins bl, b2 and b6 with different concentrations have been investigated, and the fluorescence mechanism is explained on the basis of moleoalar struchture Possible reasons of the blue-shift of the fluorescence peak and enhancement of the peak power are explained as well. The advantages of solid powder method is analyzed and discussed.展开更多
The conceptual design of mechatronic systems is addressed under the thrust of concurrent engineering and an enhanced conceptual design methodology describing the early design stage of mechatronic systems is presented ...The conceptual design of mechatronic systems is addressed under the thrust of concurrent engineering and an enhanced conceptual design methodology describing the early design stage of mechatronic systems is presented through an example illustration of a pick and place robot.This methodology treats each feasible solution as a solution strategy.In the methodology,Quality Function Deployment(QFD)is used as a baseline for the analysis of the mapping from customers to engineering requirements,Axiomatic Design(AD)is adopted as a guideline to generate feasible,good design solution alternatives,and Theory of Inventive Problem Solving(TRIZ)is applied to deal with domain conflicts in design.展开更多
基金supported by the Tianjin Natural Science Foundation(No.06YFJZJC00300)the Natural Science Foundation of China(Nos.10674075,10774077,10674074,50802044 and 60736039)
文摘The simple approach to acquire the fltaxescenee spectra of vitamin bl, b2 and t6 is proposed by direct ilhanination on solid powder sample. The experimentally acquired fluorescence spectra are in accordance with the previous measurements on soluble samples. The fluorescence spectra for a mixture of vitamins bl, b2 and b6 with different concentrations have been investigated, and the fluorescence mechanism is explained on the basis of moleoalar struchture Possible reasons of the blue-shift of the fluorescence peak and enhancement of the peak power are explained as well. The advantages of solid powder method is analyzed and discussed.
文摘The conceptual design of mechatronic systems is addressed under the thrust of concurrent engineering and an enhanced conceptual design methodology describing the early design stage of mechatronic systems is presented through an example illustration of a pick and place robot.This methodology treats each feasible solution as a solution strategy.In the methodology,Quality Function Deployment(QFD)is used as a baseline for the analysis of the mapping from customers to engineering requirements,Axiomatic Design(AD)is adopted as a guideline to generate feasible,good design solution alternatives,and Theory of Inventive Problem Solving(TRIZ)is applied to deal with domain conflicts in design.