A novel dual output phase-shift distribution transformer ( DOPSDT ) is proposed based on the electromagnetic filtering theory. First, its structural characteristics, winding connection mode and turn number ratio for...A novel dual output phase-shift distribution transformer ( DOPSDT ) is proposed based on the electromagnetic filtering theory. First, its structural characteristics, winding connection mode and turn number ratio for special phase shifting are investigated. Secondly, the balance formulation of harmonic magneto-motive forces is derived and the electromagnetic filtering principle of the DOPSDT is introduced. The harmonic mitigating performance under different nonlinear load conditions are also analyzed using the field-circuit coupled method, The analysis results show that the DOPSDT can mitigate the primary current distortion even under severe nonlinear load conditions. By applying the zero sequence flux cancellation and phase-shift techniques at their secondary windings, the DOPSDT can significantly reduce the 3rd, 5th, 7th, 9th, 15th, 17th and 19th harmonics within its secondary windings.展开更多
Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and ope...Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and operation,its insulation structure may be damaged,resulting in partial discharge and even breakdown inside the transformer.In this paper,S9-M-100/10 oil immersed distribution transformer is taken as the research object,and the distribution laws of electromagnetic field and temperature field in transformer under normal operation,inter turn short circuit and inter layer short circuit are simulated and analyzed.The simulation results show that under normal conditions,the temperatures at the oil gap between the transformer core and the high and low voltage windings and the middle position of the high-voltage winding are high.When there are inter turn and inter layer short circuit faults,the electromagnetic loss of the fault part of the transformer increases,and the temperature rises suddenly.The influence of the two faults on the internal temperature field of the transformer is different,and the influence of the inter turn short circuit fault on the temperature nearby is obvious.The analysis results can provide reference for the thermal fault interpretation and fault classification of transformer.展开更多
The generator is the starter device of single stage heat transformer(SSHT) and its characteristics have main effects on the overall efficiency of this kind of absorption machines.This article reports a study of the ge...The generator is the starter device of single stage heat transformer(SSHT) and its characteristics have main effects on the overall efficiency of this kind of absorption machines.This article reports a study of the generation of steam and changes in the concentration of the working solution(Water/Carrol mixture) into a plate heat exchanger as a function of its horizontal and vertical position by gravity effect.It is considered the analysis of six experimental tests;two were evaluated in a plate heat exchanger in a horizontal position and four in a vertical position(90 degree inclination).The generation of steam and increased concentration of the working solution are more sensitive to the vertical position of exchanger than in horizontal position.The results of numerical-experimental analysis indicates that a heat exchanger in horizontal position,the steam generation and the change in the concentration of the working solution occurring in the middle of the plate(or at greater distance depending to the thermodynamic conditions) and instantly in vertical position(at the input of the plate).展开更多
基金The Program for Special Talent in Six Fields of Jiangsu Province (2011-ZBZZ-016)the Postdoctoral Science Foundation of Jiangsu Province (No. 0902038C)
文摘A novel dual output phase-shift distribution transformer ( DOPSDT ) is proposed based on the electromagnetic filtering theory. First, its structural characteristics, winding connection mode and turn number ratio for special phase shifting are investigated. Secondly, the balance formulation of harmonic magneto-motive forces is derived and the electromagnetic filtering principle of the DOPSDT is introduced. The harmonic mitigating performance under different nonlinear load conditions are also analyzed using the field-circuit coupled method, The analysis results show that the DOPSDT can mitigate the primary current distortion even under severe nonlinear load conditions. By applying the zero sequence flux cancellation and phase-shift techniques at their secondary windings, the DOPSDT can significantly reduce the 3rd, 5th, 7th, 9th, 15th, 17th and 19th harmonics within its secondary windings.
基金Science and Technology Project of State Grid Gansu Electric Power Company(No.52272219000Q)。
文摘Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and operation,its insulation structure may be damaged,resulting in partial discharge and even breakdown inside the transformer.In this paper,S9-M-100/10 oil immersed distribution transformer is taken as the research object,and the distribution laws of electromagnetic field and temperature field in transformer under normal operation,inter turn short circuit and inter layer short circuit are simulated and analyzed.The simulation results show that under normal conditions,the temperatures at the oil gap between the transformer core and the high and low voltage windings and the middle position of the high-voltage winding are high.When there are inter turn and inter layer short circuit faults,the electromagnetic loss of the fault part of the transformer increases,and the temperature rises suddenly.The influence of the two faults on the internal temperature field of the transformer is different,and the influence of the inter turn short circuit fault on the temperature nearby is obvious.The analysis results can provide reference for the thermal fault interpretation and fault classification of transformer.
基金supporting basic science project 167434:"Analysis of waste energy recovery and sustainable development"
文摘The generator is the starter device of single stage heat transformer(SSHT) and its characteristics have main effects on the overall efficiency of this kind of absorption machines.This article reports a study of the generation of steam and changes in the concentration of the working solution(Water/Carrol mixture) into a plate heat exchanger as a function of its horizontal and vertical position by gravity effect.It is considered the analysis of six experimental tests;two were evaluated in a plate heat exchanger in a horizontal position and four in a vertical position(90 degree inclination).The generation of steam and increased concentration of the working solution are more sensitive to the vertical position of exchanger than in horizontal position.The results of numerical-experimental analysis indicates that a heat exchanger in horizontal position,the steam generation and the change in the concentration of the working solution occurring in the middle of the plate(or at greater distance depending to the thermodynamic conditions) and instantly in vertical position(at the input of the plate).