期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
电传动牵引系统辅助滤波器设计
1
作者 张蕾 刘海龙 刘三帅 《自动化技术与应用》 2021年第1期122-124,共3页
简要分析基于电传动轨道车辅助逆变单元谐波产生的机理,根据负载谐波要求,对设置交流滤波器的必要性做以说明,重点阐述交流变压滤波器的参数设计,并且通过仿真对设计参数选择做了确认。仿真及样机试验结果表明,变压滤波器参数选择对消... 简要分析基于电传动轨道车辅助逆变单元谐波产生的机理,根据负载谐波要求,对设置交流滤波器的必要性做以说明,重点阐述交流变压滤波器的参数设计,并且通过仿真对设计参数选择做了确认。仿真及样机试验结果表明,变压滤波器参数选择对消除谐波满足实际应用价值。 展开更多
关键词 谐波 MATLAB 变压滤波器 参数设计
下载PDF
Analysis of input harmonic current mitigating performance in dual output phase-shift distribution transformer
2
作者 郭健 林鹤云 房淑华 《Journal of Southeast University(English Edition)》 EI CAS 2012年第2期151-155,共5页
A novel dual output phase-shift distribution transformer ( DOPSDT ) is proposed based on the electromagnetic filtering theory. First, its structural characteristics, winding connection mode and turn number ratio for... A novel dual output phase-shift distribution transformer ( DOPSDT ) is proposed based on the electromagnetic filtering theory. First, its structural characteristics, winding connection mode and turn number ratio for special phase shifting are investigated. Secondly, the balance formulation of harmonic magneto-motive forces is derived and the electromagnetic filtering principle of the DOPSDT is introduced. The harmonic mitigating performance under different nonlinear load conditions are also analyzed using the field-circuit coupled method, The analysis results show that the DOPSDT can mitigate the primary current distortion even under severe nonlinear load conditions. By applying the zero sequence flux cancellation and phase-shift techniques at their secondary windings, the DOPSDT can significantly reduce the 3rd, 5th, 7th, 9th, 15th, 17th and 19th harmonics within its secondary windings. 展开更多
关键词 shift-phase transformer harmonic mitigating electromagnetic filtering field-circuit coupled method
下载PDF
Buck converter stability techniques for secondary filters and adaptive voltage positioning
3
作者 Yao Suyi Jiang Jianguo 《Journal of Southeast University(English Edition)》 EI CAS 2021年第3期258-263,共6页
To reduce output voltage noise and improve dynamic response performance,this study designed a buck converter on the basis of secondary filters and adaptive voltage positioning(AVP).A hybrid control method was proposed... To reduce output voltage noise and improve dynamic response performance,this study designed a buck converter on the basis of secondary filters and adaptive voltage positioning(AVP).A hybrid control method was proposed for the compensation of the secondary filter.The introduction of a high-frequency feedback path,in addition to the traditional feedback path,effectively improved the influence of the secondary filter on the loop stability and direct current regulation performance.A small-signal model of the buck converter based on the proposed control method was derived,and the stability and selection of control parameters were analyzed.AVP is realized using an easy-to-implement and low-cost control method that was proposed to improve dynamic response performance by changing the low-frequency gain of the control loop and load regulation of the output voltage.The experimental results of the buck converter showed that the proposed method effectively reduced the output voltage noise by 50%and improved the dynamic response capability to meet the target requirements of mainstream electronic systems. 展开更多
关键词 buck converter secondary filter adaptive voltage positioning(AVP) output voltage noise small-signal model
下载PDF
Water Vapor Detection System Based on Scanning Spectra
4
作者 Shicong ZHANG Qiang WANG +10 位作者 Yan ZHANG Fujun SONG Kun CHEN Guoqing CHOU Jun CHANG Pengpeng WANG Delong KONG Zongliang WANG Weijie WANG Yongning LIU Haiyong SONG 《Photonic Sensors》 SCIE EI CAS 2012年第1期71-76,共6页
Scanning the absorption spectral line of water vapor through wavelength around 1368.597nm is successfully used to measure the value of micro-moisture content. The synchronous superposition average of original signal a... Scanning the absorption spectral line of water vapor through wavelength around 1368.597nm is successfully used to measure the value of micro-moisture content. The synchronous superposition average of original signal algorithm based on labview is innovated and applied to detecting weak spectrum absorption signal instead of low pass filter. Two data processing methods are used to get the concentration of water vapor in ppm: one is a general formula method which has newly deduced a general formula to calculate the concentration of gas with temperature and beam intensity ratio when the pressure is equal to or greater than 1 atm; the other is engineering calibration method which is proved to have high resolution and accuracy with the fitted curve of beam intensity ratio and concentration in ppm when the temperature changes form 258K to 305K and the pressure ranges from 1 atm to 5 atm. 展开更多
关键词 Water-vapor detection scanning spectra detecting under high gas pressure near-infrared absorption
原文传递