The Paper introduces an IF software radio receiver development Platform based on high-speed monolithic A/D Converter AD6640, Progranunable Digital Down-converter AD6620 and high-speed DSP chip TMSC320C6701. The implem...The Paper introduces an IF software radio receiver development Platform based on high-speed monolithic A/D Converter AD6640, Progranunable Digital Down-converter AD6620 and high-speed DSP chip TMSC320C6701. The implementation method is described as well as AD6620 parameter setting analysis. It also presents a flow chart of the on-line programming with the help of PC. The algorithm for demodulation AM signal is discussed.展开更多
This letter presents a novel spatial error concealment algorithm for the H.264 video coding. The error concealment algorithm is based on directional interpolation. Mojette transform is used to estimate the orientation...This letter presents a novel spatial error concealment algorithm for the H.264 video coding. The error concealment algorithm is based on directional interpolation. Mojette transform is used to estimate the orientation features of the damaged blocks,and the image is interpolated in the appro-priate directions. The proposed method is compared with bilinear interpolation algorithm in the ref-erence implementation of H.264 and all directional interpolation. Experimental results prove that the proposed algorithm has better subjective and objective image reconstruction quality.展开更多
This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient im...This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient impedance and dominant transient frequency. The Discrete Fourier Transform (DFT) method is used to determine the dominant transient frequency. The values of voltage and current earth modes are calculated in the period of the dominant transient frequency, then the transient impedance can be determined, from which we can calculate the earth capacitance. The calculated capacitance gives an indication about if the feeder is faulted or not. The algorithm is less dependent on the fault resistance and the faulted feeder parameters; it mainly depends on the background network. The network is simulated by ATP/EMTP program. Several different fault conditions are covered in the simulation process, different fault inception angles, fault locations and fault resistances.展开更多
文摘The Paper introduces an IF software radio receiver development Platform based on high-speed monolithic A/D Converter AD6640, Progranunable Digital Down-converter AD6620 and high-speed DSP chip TMSC320C6701. The implementation method is described as well as AD6620 parameter setting analysis. It also presents a flow chart of the on-line programming with the help of PC. The algorithm for demodulation AM signal is discussed.
基金the National Natural Science Foundation of China (No.60472036, 60402036)the Natural Science Foundation of Beijing (No.4042008)the Ph.D. Foundation of Ministry of Education (No.20040005015).
文摘This letter presents a novel spatial error concealment algorithm for the H.264 video coding. The error concealment algorithm is based on directional interpolation. Mojette transform is used to estimate the orientation features of the damaged blocks,and the image is interpolated in the appro-priate directions. The proposed method is compared with bilinear interpolation algorithm in the ref-erence implementation of H.264 and all directional interpolation. Experimental results prove that the proposed algorithm has better subjective and objective image reconstruction quality.
文摘This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient impedance and dominant transient frequency. The Discrete Fourier Transform (DFT) method is used to determine the dominant transient frequency. The values of voltage and current earth modes are calculated in the period of the dominant transient frequency, then the transient impedance can be determined, from which we can calculate the earth capacitance. The calculated capacitance gives an indication about if the feeder is faulted or not. The algorithm is less dependent on the fault resistance and the faulted feeder parameters; it mainly depends on the background network. The network is simulated by ATP/EMTP program. Several different fault conditions are covered in the simulation process, different fault inception angles, fault locations and fault resistances.