This article describes the development of automatic control system on the basis of Festo "Compact Workstation" training stand. Such control systems are used in different branches of industry and infrastructure inclu...This article describes the development of automatic control system on the basis of Festo "Compact Workstation" training stand. Such control systems are used in different branches of industry and infrastructure including oil industry, chemical industry, water treatment, canalization and others. The stand allows realizing level, flow, pressure and temperature control systems, using pump, valves, discrete and analog sensors. Level control system is described in this work. PID (proportional integral derivative) controllers are used in these systems. Control is switched on and off and the parameters of control systems are changed by means of SCADA (supervisory control and data acquisition) system. During real technological processes, these actions are performed by the operator. The algorithm of the control system is realized using PLC (programmable logic controller). At the end of the article conclusions about the research are drawn.展开更多
Broadband PLC (power line communication) technology is a main factor of the development of digital convergence in the indoor network. It uses the already existing power cable infrastructure for communication purpose...Broadband PLC (power line communication) technology is a main factor of the development of digital convergence in the indoor network. It uses the already existing power cable infrastructure for communication purposes. The EM (electromagnetic) field radiating from the cable could, however, disturb other communication systems, and thus should be evaluated. The MoM (method of moment) and the FEM (finite element method) have been studied to estimate the EVI field emitted from the power cable. However, the M oM is difficult to treat the dielectric material of the cable and the FEM is time consuming. This paperpresents a new approach to estimate the radiated EM fields caused by PLC sy stems from the CM current along the cable, based on the transmission line theory. The proposed model has the advantage of using the measured primary parameters of the cable. An experimental analysis of the EM radiation distribution is also presented. A comparison showed that the model results agree quite well with the measurements performed in this study.展开更多
文摘This article describes the development of automatic control system on the basis of Festo "Compact Workstation" training stand. Such control systems are used in different branches of industry and infrastructure including oil industry, chemical industry, water treatment, canalization and others. The stand allows realizing level, flow, pressure and temperature control systems, using pump, valves, discrete and analog sensors. Level control system is described in this work. PID (proportional integral derivative) controllers are used in these systems. Control is switched on and off and the parameters of control systems are changed by means of SCADA (supervisory control and data acquisition) system. During real technological processes, these actions are performed by the operator. The algorithm of the control system is realized using PLC (programmable logic controller). At the end of the article conclusions about the research are drawn.
文摘Broadband PLC (power line communication) technology is a main factor of the development of digital convergence in the indoor network. It uses the already existing power cable infrastructure for communication purposes. The EM (electromagnetic) field radiating from the cable could, however, disturb other communication systems, and thus should be evaluated. The MoM (method of moment) and the FEM (finite element method) have been studied to estimate the EVI field emitted from the power cable. However, the M oM is difficult to treat the dielectric material of the cable and the FEM is time consuming. This paperpresents a new approach to estimate the radiated EM fields caused by PLC sy stems from the CM current along the cable, based on the transmission line theory. The proposed model has the advantage of using the measured primary parameters of the cable. An experimental analysis of the EM radiation distribution is also presented. A comparison showed that the model results agree quite well with the measurements performed in this study.