A model that rapidly predicts the density components of raw coal is described.It is based on a threegrade fast float/sink test.The recent comprehensive monthly floating and sinking data are used for comparison.The pre...A model that rapidly predicts the density components of raw coal is described.It is based on a threegrade fast float/sink test.The recent comprehensive monthly floating and sinking data are used for comparison.The predicted data are used to draw washability curves and to provide a rapid evaluation of the effect from heavy medium induced separation.Thirty-one production shifts worth of fast float/sink data and the corresponding quick ash data are used to verify the model.The results show a small error with an arithmetic average of 0.53 and an absolute average error of 1.50.This indicates that this model has high precision.The theoretical yield from the washability curves is 76.47% for the monthly comprehensive data and 81.31% using the model data.This is for a desired cleaned coal ash of 9%.The relative error between these two is 6.33%,which is small and indicates that the predicted data can be used to rapidly evaluate the separation effect of gravity separation equipment.展开更多
Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expans...Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expansion method. The errors were used to establish optimum measurement positions. The results show that the measurement position should be in the middle of the column and in the region half way from the center to the wall (the half-radius). The gas holdup along the axial direction is lower at the bottom and higher at the top of the floatation column. The gas holdup along the radial direction is lower near the wall and higher near the center of the flotation column. The average gas holdup measure- ment can be replaced by regional gas holdup values.展开更多
基金National Natural Science Foundation of China (No. 51174202)Doctoral Fund of Ministry of Education of China (No. 20100095110013)
文摘A model that rapidly predicts the density components of raw coal is described.It is based on a threegrade fast float/sink test.The recent comprehensive monthly floating and sinking data are used for comparison.The predicted data are used to draw washability curves and to provide a rapid evaluation of the effect from heavy medium induced separation.Thirty-one production shifts worth of fast float/sink data and the corresponding quick ash data are used to verify the model.The results show a small error with an arithmetic average of 0.53 and an absolute average error of 1.50.This indicates that this model has high precision.The theoretical yield from the washability curves is 76.47% for the monthly comprehensive data and 81.31% using the model data.This is for a desired cleaned coal ash of 9%.The relative error between these two is 6.33%,which is small and indicates that the predicted data can be used to rapidly evaluate the separation effect of gravity separation equipment.
基金supports for this work provided by the NationalKey Technology R&D Program in the 11th Five-Year Plan of China(No. 2008BAB31B03)
文摘Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expansion method. The errors were used to establish optimum measurement positions. The results show that the measurement position should be in the middle of the column and in the region half way from the center to the wall (the half-radius). The gas holdup along the axial direction is lower at the bottom and higher at the top of the floatation column. The gas holdup along the radial direction is lower near the wall and higher near the center of the flotation column. The average gas holdup measure- ment can be replaced by regional gas holdup values.