Studies on landslides by the 2008 Wenchuan earthquake showed that topography was of great importance in amplifying the seismic shaking, and among other factors, lithology and slope structure controlled the spatial occ...Studies on landslides by the 2008 Wenchuan earthquake showed that topography was of great importance in amplifying the seismic shaking, and among other factors, lithology and slope structure controlled the spatial occurrence of slope failures. The present study carried out experiments on four rock slopes with steep angle of 60° by means of a shaking table. The recorded Wenchuan earthquake waves were scaled to excite the model slopes. Measurements from accelerometers installed on free surface of the model slope were analyzed, with much effort on timedomain acceleration responses to horizontal components of seismic shaking. It was found that the amplification factor of peak horizontal acceleration, RPHA, was increasing with elevation of each model slope, though the upper and lower halves of the slope exhibited different increasing patterns. As excitation intensity was increased, the drastic deterioration of the inner structure of each slope caused the sudden increase of RPHA in the upper slope part. In addition, the model simulating the soft rock slope produced the larger RPHA than the model simulating the hard rock slope by a maximum factor of 2.6. The layered model slope also produced the larger RPHA than the homogeneous model slope by a maximum factor of 2.7. The upper half of a slope was influenced more seriously by the effect of lithology, while the lower half was influenced more seriously by the effect of slope structure.展开更多
Based on the former performance capacity experiments of the magnet-friction energy dissipation devices, including the permanent magnet-friction energy dissipation device (PMF) and electromagnet-friction energy dissipa...Based on the former performance capacity experiments of the magnet-friction energy dissipation devices, including the permanent magnet-friction energy dissipation device (PMF) and electromagnet-friction energy dissipation devices (EMF), a 5-story steel frame model with spacious first story is designed and made according to a scale of 1/4. The magnet-friction energy dissipation devices can realize continuously varied controlling force, with rapid response and reverse recognition. Therefore, they overcome shortcomings usually found in energy dissipation devices whose force models are invariable. The two kinds of devices were fixed on the flexible first story of the structure model, and the shaking table tests have been carried out, respectively. In these tests, the performance of the devices and their effectiveness in structural control were confirmed. In this paper, the test results and analysis are discussed.展开更多
This study gives a comparison between what occurs when braking on a MOT (Ministry of Transport) brake tester. The results from this research and the exhaustive comparative study carried out by the mechanical enginee...This study gives a comparison between what occurs when braking on a MOT (Ministry of Transport) brake tester. The results from this research and the exhaustive comparative study carried out by the mechanical engineering staffs at the mechanical laboratory at MOT stations in cities such as: Elche, Pilar de la Horadada and Orihuela from Alicante region [2] have led to the following main conclusions: this paper demonstrates that MOT brake testing results can vary depending on parameters variation such as: distance between rollers, roller diameter, roughness of rollers and velocity of the brake test.展开更多
基金financially supported by the National Basic Research Program "973" Project of the Ministry of Science and Technology of the People’s Republic of China (Grant No. 2013CB733200)the National Science Found for Distinguished Young Scholars of China (Grant No. 41225011)the Chang Jiang Scholars Program of China and the open fund on "Research on largescale landslides triggered by the Wenchuan earthquake" provided by the State Key Laboratory of Geohazard Prevention and Geoenvironment Protection
文摘Studies on landslides by the 2008 Wenchuan earthquake showed that topography was of great importance in amplifying the seismic shaking, and among other factors, lithology and slope structure controlled the spatial occurrence of slope failures. The present study carried out experiments on four rock slopes with steep angle of 60° by means of a shaking table. The recorded Wenchuan earthquake waves were scaled to excite the model slopes. Measurements from accelerometers installed on free surface of the model slope were analyzed, with much effort on timedomain acceleration responses to horizontal components of seismic shaking. It was found that the amplification factor of peak horizontal acceleration, RPHA, was increasing with elevation of each model slope, though the upper and lower halves of the slope exhibited different increasing patterns. As excitation intensity was increased, the drastic deterioration of the inner structure of each slope caused the sudden increase of RPHA in the upper slope part. In addition, the model simulating the soft rock slope produced the larger RPHA than the model simulating the hard rock slope by a maximum factor of 2.6. The layered model slope also produced the larger RPHA than the homogeneous model slope by a maximum factor of 2.7. The upper half of a slope was influenced more seriously by the effect of lithology, while the lower half was influenced more seriously by the effect of slope structure.
文摘Based on the former performance capacity experiments of the magnet-friction energy dissipation devices, including the permanent magnet-friction energy dissipation device (PMF) and electromagnet-friction energy dissipation devices (EMF), a 5-story steel frame model with spacious first story is designed and made according to a scale of 1/4. The magnet-friction energy dissipation devices can realize continuously varied controlling force, with rapid response and reverse recognition. Therefore, they overcome shortcomings usually found in energy dissipation devices whose force models are invariable. The two kinds of devices were fixed on the flexible first story of the structure model, and the shaking table tests have been carried out, respectively. In these tests, the performance of the devices and their effectiveness in structural control were confirmed. In this paper, the test results and analysis are discussed.
文摘This study gives a comparison between what occurs when braking on a MOT (Ministry of Transport) brake tester. The results from this research and the exhaustive comparative study carried out by the mechanical engineering staffs at the mechanical laboratory at MOT stations in cities such as: Elche, Pilar de la Horadada and Orihuela from Alicante region [2] have led to the following main conclusions: this paper demonstrates that MOT brake testing results can vary depending on parameters variation such as: distance between rollers, roller diameter, roughness of rollers and velocity of the brake test.