This paper developed a statistical damage constitutive model for deep rock by considering the effects of external load and thermal treatment temperature based on the distortion energy.The model parameters were determi...This paper developed a statistical damage constitutive model for deep rock by considering the effects of external load and thermal treatment temperature based on the distortion energy.The model parameters were determined through the extremum features of stress−strain curve.Subsequently,the model predictions were compared with experimental results of marble samples.It is found that when the treatment temperature rises,the coupling damage evolution curve shows an S-shape and the slope of ascending branch gradually decreases during the coupling damage evolution process.At a constant temperature,confining pressure can suppress the expansion of micro-fractures.As the confining pressure increases the rock exhibits ductility characteristics,and the shape of coupling damage curve changes from an S-shape into a quasi-parabolic shape.This model can well characterize the influence of high temperature on the mechanical properties of deep rock and its brittleness-ductility transition characteristics under confining pressure.Also,it is suitable for sandstone and granite,especially in predicting the pre-peak stage and peak stress of stress−strain curve under the coupling action of confining pressure and high temperature.The relevant results can provide a reference for further research on the constitutive relationship of rock-like materials and their engineering applications.展开更多
A new kind offl biomedical titanium alloy, Ti-35Nb-4Sn-6Mo-9Zr, composed of non-toxic elements Nb, Mo, Zr and Sn with lower elastic modulus and higher strength was designed based on d-electron alloy design theory and ...A new kind offl biomedical titanium alloy, Ti-35Nb-4Sn-6Mo-9Zr, composed of non-toxic elements Nb, Mo, Zr and Sn with lower elastic modulus and higher strength was designed based on d-electron alloy design theory and JMatPro software using orthogonal experiment. The microstructure and basic mechanical properties of designed alloy were investigated. The results show that the alloy is composed of single fl equiaxed grains after solution treatment at 800 ~C. Compared with Ti-6A1-4V, the mechanical properties of the designed alloy are more excellent: E=65 GPa, σb=834 MPa, σ0.2=802 MPa, and σ=11%, which is expected to become a promising new type implanted material. The research approach adopted can reduce the experimental time and cost effectively, and get the ideal experimental results.展开更多
The oil film clutch, which is superior in speed adjustment, is capable of being used in the belt conveyor to carry out soft start operation. According to running properties of both belt conveyor and oil film clutch...The oil film clutch, which is superior in speed adjustment, is capable of being used in the belt conveyor to carry out soft start operation. According to running properties of both belt conveyor and oil film clutch, equations that are used to decide the lubricating oil flow and the number of oil films (i.e. the number of rotating and stationary plates) are deduced theoretically. Also key parameters are provided for the design of the hydraulic system. All these together provide the theoretical basis for the soft start design of the belt conveyor and references for the application of the oil film clutch in similar fields.展开更多
Aim To investigate the combined effect of hydroxypropyl-β-cyclodextrin (HP-β-CD) and media pH on the solubility of prostaglandin E1 (PGE1) and construct a theoretical equation for the drug solubility as a functi...Aim To investigate the combined effect of hydroxypropyl-β-cyclodextrin (HP-β-CD) and media pH on the solubility of prostaglandin E1 (PGE1) and construct a theoretical equation for the drug solubility as a function of HP-β-CD concentration and media pH. Methods The solubility of PGE1 under different pH conditions was determined. Then, the drug solubility in different concentrations of HP-β-CD acidic or pH neutral solutions was measured, respectively. Finally, a theoretical solubility equation for the drug as a function of HP-β-CD concentration and media pH was deduced and confirmed in experiment. Results PGEs was solubilized by HP-β-CD or by increasing media pH. The drug solubility as a function of HP-β-CD concentration was found to follow the AL-type complexation model in acidic or neutral pH media, suggesting that both the ionized and neutral drugs form 1:1 molecular ratio complexes. Conclusions The solubility of PGE1 may be improved by increasing media pH or by using HP-β-CD as a solubilizer. HP-β-CD and media pH can produce combined effect on the solubility of PGE1. The deduced equation for the drug solubility in this study effectively characterizes the roles of HP-β-CD and media pH in determining total solubility of the drug.展开更多
In the work of developing extrinsic fabry perot interferometric (EFPI), the key technology of polishing fiber optic endfaces and coating the multilayer of dielectric films on them is raised and resolved to settle the...In the work of developing extrinsic fabry perot interferometric (EFPI), the key technology of polishing fiber optic endfaces and coating the multilayer of dielectric films on them is raised and resolved to settle the disturbance and stability problem of EFPI, which simplifies the sensing system, improves the sensor performance and reduces the cost. In this paper, the relations between the output interferential light intensity and the F P cavity length are calculated based on the theory of mode field coupling. The EFPI fiber optic sensor is adhered to a distributed smart laminate beam to detect vibration frequency and axial strain value, the results coincident with the results tested by PZT.展开更多
基金Project(11272119)supported by the National Natural Science Foundation of China。
文摘This paper developed a statistical damage constitutive model for deep rock by considering the effects of external load and thermal treatment temperature based on the distortion energy.The model parameters were determined through the extremum features of stress−strain curve.Subsequently,the model predictions were compared with experimental results of marble samples.It is found that when the treatment temperature rises,the coupling damage evolution curve shows an S-shape and the slope of ascending branch gradually decreases during the coupling damage evolution process.At a constant temperature,confining pressure can suppress the expansion of micro-fractures.As the confining pressure increases the rock exhibits ductility characteristics,and the shape of coupling damage curve changes from an S-shape into a quasi-parabolic shape.This model can well characterize the influence of high temperature on the mechanical properties of deep rock and its brittleness-ductility transition characteristics under confining pressure.Also,it is suitable for sandstone and granite,especially in predicting the pre-peak stage and peak stress of stress−strain curve under the coupling action of confining pressure and high temperature.The relevant results can provide a reference for further research on the constitutive relationship of rock-like materials and their engineering applications.
基金Project(BE2011778)supported by Science and Technology Support Program of Jiangsu Province,ChinaProject(20133069014)supported by Aeronautical Science Foundation of China
文摘A new kind offl biomedical titanium alloy, Ti-35Nb-4Sn-6Mo-9Zr, composed of non-toxic elements Nb, Mo, Zr and Sn with lower elastic modulus and higher strength was designed based on d-electron alloy design theory and JMatPro software using orthogonal experiment. The microstructure and basic mechanical properties of designed alloy were investigated. The results show that the alloy is composed of single fl equiaxed grains after solution treatment at 800 ~C. Compared with Ti-6A1-4V, the mechanical properties of the designed alloy are more excellent: E=65 GPa, σb=834 MPa, σ0.2=802 MPa, and σ=11%, which is expected to become a promising new type implanted material. The research approach adopted can reduce the experimental time and cost effectively, and get the ideal experimental results.
文摘The oil film clutch, which is superior in speed adjustment, is capable of being used in the belt conveyor to carry out soft start operation. According to running properties of both belt conveyor and oil film clutch, equations that are used to decide the lubricating oil flow and the number of oil films (i.e. the number of rotating and stationary plates) are deduced theoretically. Also key parameters are provided for the design of the hydraulic system. All these together provide the theoretical basis for the soft start design of the belt conveyor and references for the application of the oil film clutch in similar fields.
文摘Aim To investigate the combined effect of hydroxypropyl-β-cyclodextrin (HP-β-CD) and media pH on the solubility of prostaglandin E1 (PGE1) and construct a theoretical equation for the drug solubility as a function of HP-β-CD concentration and media pH. Methods The solubility of PGE1 under different pH conditions was determined. Then, the drug solubility in different concentrations of HP-β-CD acidic or pH neutral solutions was measured, respectively. Finally, a theoretical solubility equation for the drug as a function of HP-β-CD concentration and media pH was deduced and confirmed in experiment. Results PGEs was solubilized by HP-β-CD or by increasing media pH. The drug solubility as a function of HP-β-CD concentration was found to follow the AL-type complexation model in acidic or neutral pH media, suggesting that both the ionized and neutral drugs form 1:1 molecular ratio complexes. Conclusions The solubility of PGE1 may be improved by increasing media pH or by using HP-β-CD as a solubilizer. HP-β-CD and media pH can produce combined effect on the solubility of PGE1. The deduced equation for the drug solubility in this study effectively characterizes the roles of HP-β-CD and media pH in determining total solubility of the drug.
文摘In the work of developing extrinsic fabry perot interferometric (EFPI), the key technology of polishing fiber optic endfaces and coating the multilayer of dielectric films on them is raised and resolved to settle the disturbance and stability problem of EFPI, which simplifies the sensing system, improves the sensor performance and reduces the cost. In this paper, the relations between the output interferential light intensity and the F P cavity length are calculated based on the theory of mode field coupling. The EFPI fiber optic sensor is adhered to a distributed smart laminate beam to detect vibration frequency and axial strain value, the results coincident with the results tested by PZT.