After exposure of one-year old seedlings of Swietenia macrophylla to an overnight temperature (13 C, 19 C, 25 C, 31 C or 35 C), the leaf net photosynthetic rate (Pn) was researched through measuring photosynthetic lig...After exposure of one-year old seedlings of Swietenia macrophylla to an overnight temperature (13 C, 19 C, 25 C, 31 C or 35 C), the leaf net photosynthetic rate (Pn) was researched through measuring photosynthetic light-response curves at 360 mmolmol-1 CO2, and photosynthetic CO2-response curves at light-saturated intensity (1500 mmolm-2 s-1). The optimal temperature for photosynthesis measured at 360 mmol穖ol-1 CO2 was from 25 C to 31 C, but which was from 31C to 35 C at saturating CO2 concentration. At temperature of below 25 C, the decline in Pn was mainly due to the drop in carboxylation efficiency (Ce), while as temperature was over 31 C, the reduction in Pn resulted from both decrease in Ce and increase in leaf respiration. The CO2-induced stimulation of photosynthesis was strongly inhibited at temperatures below 13 C. The results showed that, the leaf photosynthesis of tropical evergreen plants should not be accelerated at low temperature in winter season with elevated CO2 concentration in the future.展开更多
A new fluorescence silver nanosensor assisted by surfactant has been synthesized and applied to ultra trace nickel determination. Operational variables which influence nanomaterial synthesis have been studied and opti...A new fluorescence silver nanosensor assisted by surfactant has been synthesized and applied to ultra trace nickel determination. Operational variables which influence nanomaterial synthesis have been studied and optimized. Synthesis was very fast and simple using non polluting solvents; silver chemical reduction was carried out at room temperature. Spectroscopic studies were carried out in order to assure the uniformed of nanomaterial obtained. Fluorescent signal of silver nanoparticles resulted enhanced in presence of Ni(II). At optimal experimental conditions, a detection limit of 0.036 pg'L1 and quantification limit 0.12 pg'L~ were obtained. The calibration sensitivity was 2 x 1014 L.pg-l.cm1 for the new methodology, with a range of linearity of six orders of magnitude between 0.12 and 2.93 × 10^5 pg L^-1. The tolerance levels for potential interferent ions were studied with good results. The proposed methodology represents a promising approach for Ni(II) traces quantification due to its low operation cost, simplicity of instrumentation, high sampling speed and non-polluting solvents.展开更多
文摘After exposure of one-year old seedlings of Swietenia macrophylla to an overnight temperature (13 C, 19 C, 25 C, 31 C or 35 C), the leaf net photosynthetic rate (Pn) was researched through measuring photosynthetic light-response curves at 360 mmolmol-1 CO2, and photosynthetic CO2-response curves at light-saturated intensity (1500 mmolm-2 s-1). The optimal temperature for photosynthesis measured at 360 mmol穖ol-1 CO2 was from 25 C to 31 C, but which was from 31C to 35 C at saturating CO2 concentration. At temperature of below 25 C, the decline in Pn was mainly due to the drop in carboxylation efficiency (Ce), while as temperature was over 31 C, the reduction in Pn resulted from both decrease in Ce and increase in leaf respiration. The CO2-induced stimulation of photosynthesis was strongly inhibited at temperatures below 13 C. The results showed that, the leaf photosynthesis of tropical evergreen plants should not be accelerated at low temperature in winter season with elevated CO2 concentration in the future.
文摘A new fluorescence silver nanosensor assisted by surfactant has been synthesized and applied to ultra trace nickel determination. Operational variables which influence nanomaterial synthesis have been studied and optimized. Synthesis was very fast and simple using non polluting solvents; silver chemical reduction was carried out at room temperature. Spectroscopic studies were carried out in order to assure the uniformed of nanomaterial obtained. Fluorescent signal of silver nanoparticles resulted enhanced in presence of Ni(II). At optimal experimental conditions, a detection limit of 0.036 pg'L1 and quantification limit 0.12 pg'L~ were obtained. The calibration sensitivity was 2 x 1014 L.pg-l.cm1 for the new methodology, with a range of linearity of six orders of magnitude between 0.12 and 2.93 × 10^5 pg L^-1. The tolerance levels for potential interferent ions were studied with good results. The proposed methodology represents a promising approach for Ni(II) traces quantification due to its low operation cost, simplicity of instrumentation, high sampling speed and non-polluting solvents.