The dissociative photoionization of cyclopentanone was investigated by means of a reflectron time-of-flight mass spectrometer(RTOF-MS)with tunable vacuum ultraviolet synchrotron radiation in the photon energy range of...The dissociative photoionization of cyclopentanone was investigated by means of a reflectron time-of-flight mass spectrometer(RTOF-MS)with tunable vacuum ultraviolet synchrotron radiation in the photon energy range of 9.0~15.5 eV.The photoionization efficiency(PIE)curves for molecular ion and fragment ions were measured.The ionization energy of cyclopentanone was determined to be 9.230.03 eV.Fragment ions from the dissociative photoionization of cyclopentanone were identified as C5H7O+,C4H5O+,C4H8+/C3H4O+,C3H3O+,C4H6+,C2H4O+,C3H6+,C3H5+,C3H4+,C3H3+,C2H5+and C2H4+.With the aid of the ab initio calculations at theωB97X-D/6-31+G(d,p)level of theory,the dissociative mechanisms of C5H8O+are proposed.Ring opening and hydrogen migrations are the predominant processes in most of the fragmentation pathways of cyclopentanone.展开更多
Vacuum ultraviolet(VUV)photoionization and photodissociation of methylcyclohexane have been studied utilizing a reflectron time-of-flight mass spectrometer(RTOF-MS)with synchrotron radiation source.Photoionization eff...Vacuum ultraviolet(VUV)photoionization and photodissociation of methylcyclohexane have been studied utilizing a reflectron time-of-flight mass spectrometer(RTOF-MS)with synchrotron radiation source.Photoionization efficiency curves(PIEs)of molecule ion C7H14^+ and fragment ions C7H13^+,C6H11^+,C6H10+,C5H10^+,C5H9^+,C4H8^+,C4H7^+,and C3H5^+ were observed.The ionization energy of methylcyclohexane was measured to be(9.80±0.03)eV,and appearance energies of fragment ions were determined from the PIEs.Optimized structures of transitional states,intermediates and product ions were characterized at the B3LYP/6-31G(d)level and the energies were calculated using G3B3 method.Formation channels of dominating fragment ions were proposed.Intramolecular hydrogen migrations and carbon ring-opening were the foremost processes in fragmentation pathways of methylcyclohexane.展开更多
Subsynchronous oscillation (SSO) with low amplitude that exceeds cumulative fatigue threshold of the generator shaft frequently could significantly reduce the shaft's service life, which is a new SSO problem that ...Subsynchronous oscillation (SSO) with low amplitude that exceeds cumulative fatigue threshold of the generator shaft frequently could significantly reduce the shaft's service life, which is a new SSO problem that emerges in recent years. According to the real recording oscillograph, the basic reason for frequently over-threshold SSO with low amplitude at multi-power plants was analyzed based on Hulunbuir League system. The sensitivities of the electrical damping to the main electrical parameters in the contributing loop of subsynchronous torsional interaction were calculated. Based on the sensitivities, a simulation method was presented, which was used to excite the same oscillation as the actual case by exerting disturbance on the firing angle. The limitation of wide-band and narrow-band supplementary subsynchronous damping controller (SSDC) for mitigating this kind of SSO was analyzed based on the electromagnetic transient simulation model of Hulunbuir League system. The difference of supplementary excitation damping controller (SEDC) and parallel-form FACTS connected to the generator terminal was compared from the aspects of response time and the ability of damping torque supplying. The analysis indicates that their response time is similar but FACTS has stronger ability of damping torque supplying than SEDC. Time-domain simulation method was used to compare the mitigation effects of SEDC, static var compensator (SVC) and static synchronous compensator (STATCOM). Considering the mitigation effect, the floor space limit of the power plant and so on, STATCOM was considered as the best mitigation measure. A control strategy of cascaded STATCOM for engineering application was presented and the capacity for SSO mitigation as well as output characteristics was analyzed. The analysis indicates that STATCOM using the proposed control strategy has better mitigation effect and output characteristics with smaller capacity.展开更多
基金supported by the National Natural Science Foundation of China (No.91544105, No.U1532137, No.U1232209, and No.11575178)
文摘The dissociative photoionization of cyclopentanone was investigated by means of a reflectron time-of-flight mass spectrometer(RTOF-MS)with tunable vacuum ultraviolet synchrotron radiation in the photon energy range of 9.0~15.5 eV.The photoionization efficiency(PIE)curves for molecular ion and fragment ions were measured.The ionization energy of cyclopentanone was determined to be 9.230.03 eV.Fragment ions from the dissociative photoionization of cyclopentanone were identified as C5H7O+,C4H5O+,C4H8+/C3H4O+,C3H3O+,C4H6+,C2H4O+,C3H6+,C3H5+,C3H4+,C3H3+,C2H5+and C2H4+.With the aid of the ab initio calculations at theωB97X-D/6-31+G(d,p)level of theory,the dissociative mechanisms of C5H8O+are proposed.Ring opening and hydrogen migrations are the predominant processes in most of the fragmentation pathways of cyclopentanone.
基金supported by the National Natural Science Foundation of China(No.91544105,No.41275127,No.U1532137 and No.11575178)。
文摘Vacuum ultraviolet(VUV)photoionization and photodissociation of methylcyclohexane have been studied utilizing a reflectron time-of-flight mass spectrometer(RTOF-MS)with synchrotron radiation source.Photoionization efficiency curves(PIEs)of molecule ion C7H14^+ and fragment ions C7H13^+,C6H11^+,C6H10+,C5H10^+,C5H9^+,C4H8^+,C4H7^+,and C3H5^+ were observed.The ionization energy of methylcyclohexane was measured to be(9.80±0.03)eV,and appearance energies of fragment ions were determined from the PIEs.Optimized structures of transitional states,intermediates and product ions were characterized at the B3LYP/6-31G(d)level and the energies were calculated using G3B3 method.Formation channels of dominating fragment ions were proposed.Intramolecular hydrogen migrations and carbon ring-opening were the foremost processes in fragmentation pathways of methylcyclohexane.
基金supported by the Key Project of the National 12th Five-Year Research Programme of China (Grant No. 2011BAA01B02)the Fundamental Research Funds for the Central Universities of China (Grant No.12QN37)
文摘Subsynchronous oscillation (SSO) with low amplitude that exceeds cumulative fatigue threshold of the generator shaft frequently could significantly reduce the shaft's service life, which is a new SSO problem that emerges in recent years. According to the real recording oscillograph, the basic reason for frequently over-threshold SSO with low amplitude at multi-power plants was analyzed based on Hulunbuir League system. The sensitivities of the electrical damping to the main electrical parameters in the contributing loop of subsynchronous torsional interaction were calculated. Based on the sensitivities, a simulation method was presented, which was used to excite the same oscillation as the actual case by exerting disturbance on the firing angle. The limitation of wide-band and narrow-band supplementary subsynchronous damping controller (SSDC) for mitigating this kind of SSO was analyzed based on the electromagnetic transient simulation model of Hulunbuir League system. The difference of supplementary excitation damping controller (SEDC) and parallel-form FACTS connected to the generator terminal was compared from the aspects of response time and the ability of damping torque supplying. The analysis indicates that their response time is similar but FACTS has stronger ability of damping torque supplying than SEDC. Time-domain simulation method was used to compare the mitigation effects of SEDC, static var compensator (SVC) and static synchronous compensator (STATCOM). Considering the mitigation effect, the floor space limit of the power plant and so on, STATCOM was considered as the best mitigation measure. A control strategy of cascaded STATCOM for engineering application was presented and the capacity for SSO mitigation as well as output characteristics was analyzed. The analysis indicates that STATCOM using the proposed control strategy has better mitigation effect and output characteristics with smaller capacity.