It was concluded that the described HPLC method could be used for the assayof salmon calcitonin in injection, as it offers qualified selectivity, accuracy and precision ofanalysis.
A novel technique for the quick measurement moisture content of coal powder by microwave was studied. The effects of the various moisture contents on the measurement results were also discussed. The experimental resul...A novel technique for the quick measurement moisture content of coal powder by microwave was studied. The effects of the various moisture contents on the measurement results were also discussed. The experimental results show that the standard deviation is less than 0.36% when the moisture content of coal powder is 0.74%-16.90% and the standard deviation is less than 0.16% when the moisture content is 0.31%-1.49%. The experimental results indicate that a process of quick measurement moisture content of coal powder by microwave is practical.展开更多
In this study, the main factors influencing the measurements by means of the off-line low-field 1H NMR in the lab were discussed base on a robust calibration model established by the PLS algorithm using 255 crude oil ...In this study, the main factors influencing the measurements by means of the off-line low-field 1H NMR in the lab were discussed base on a robust calibration model established by the PLS algorithm using 255 crude oil samples. The preheating temperature had a great influence on the viscosity of oil samples and the resolution of spectral analysis. The repeatability of spectral measurements was impacted by the metal and wax content of the oil samples. For the case of high wax content oils, the wax species began to crystallize in the course of determination that could affect the repeatability of spectral measurements. These factors have evidenced why the preheating devices and filter unit are necessary when low field NMR system is used in the online analysis process. The investigation is very important for the on-line application of the low field NMR.展开更多
Curcuma wenyujin has been widely used as a traditional medicine in China. In this paper a strategy for the quantitative determination of the polysaccharide by a phenol-sulfuric acid method was described. Involved in t...Curcuma wenyujin has been widely used as a traditional medicine in China. In this paper a strategy for the quantitative determination of the polysaccharide by a phenol-sulfuric acid method was described. Involved in three factors, 5% phenol volume, H2SO4 volume, and temperature of water bath, we adopted the L9(3)3 orthogonal array design to gain the optimal colorimetric method. 3.0 ml of polysaccharide solution, 1.0 ml, 5% phenol and 7.0 ml H2SO4 were mixed with constant stirring in a glass vessel, and then kept in a water bath at 40 ℃. After cooling to room temperature for 20 min, the absorbance values were recorded by the UV-2501 PC spectrometer at the wavelength range of 485 nm. The polysaccharide content in Curcuma wenyujin were 3.21%, 3.23%, 3.20%, 3.18~/0, 3.22% and 2.38%, respectively. All results showed that this method was adequate, valid and applicable, may be applied to the determination of other bacterial polysaccharide as well.展开更多
In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorpti...In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorption/desorption device. Based on the characteristics of gas desorption from coal samples, we proposed a direct fitting method for measurement of gas content in coalbed, analyzed the effects of sampling time on the measurement results and determined the reasonable sampling time of coal samples with different metamorphic grades at different gas adsorption pressure at equilibrium. The results show that (1)the error of gas contents obtained using the direct fitting method relative to that obtained using indirect method is less than 10%, which meets the actual on-site requirements and verifies the feasibility of the direct fitting method;(2) when the relative error is controlled within ±10%, the reasonable sampling time of coal samples is linearly related to the gas adsorption pressure at equilibrium;(3) the reasonable sampling time of coal samples with the same metamorphic grade exhibits a shortening trend with increasing gas adsorption pressure at equilibrium;(4) for coal samples with similar gas adsorption pressure at equilibrium, the reasonable sampling time of coal samples displays a shortening trend with increasing metamorphic grade. Overall, the study provides a basis for improving the measurement accuracy of gas content in coalbed.展开更多
文摘It was concluded that the described HPLC method could be used for the assayof salmon calcitonin in injection, as it offers qualified selectivity, accuracy and precision ofanalysis.
文摘A novel technique for the quick measurement moisture content of coal powder by microwave was studied. The effects of the various moisture contents on the measurement results were also discussed. The experimental results show that the standard deviation is less than 0.36% when the moisture content of coal powder is 0.74%-16.90% and the standard deviation is less than 0.16% when the moisture content is 0.31%-1.49%. The experimental results indicate that a process of quick measurement moisture content of coal powder by microwave is practical.
基金the financial support from the SINOPEC (ST 13028)
文摘In this study, the main factors influencing the measurements by means of the off-line low-field 1H NMR in the lab were discussed base on a robust calibration model established by the PLS algorithm using 255 crude oil samples. The preheating temperature had a great influence on the viscosity of oil samples and the resolution of spectral analysis. The repeatability of spectral measurements was impacted by the metal and wax content of the oil samples. For the case of high wax content oils, the wax species began to crystallize in the course of determination that could affect the repeatability of spectral measurements. These factors have evidenced why the preheating devices and filter unit are necessary when low field NMR system is used in the online analysis process. The investigation is very important for the on-line application of the low field NMR.
文摘Curcuma wenyujin has been widely used as a traditional medicine in China. In this paper a strategy for the quantitative determination of the polysaccharide by a phenol-sulfuric acid method was described. Involved in three factors, 5% phenol volume, H2SO4 volume, and temperature of water bath, we adopted the L9(3)3 orthogonal array design to gain the optimal colorimetric method. 3.0 ml of polysaccharide solution, 1.0 ml, 5% phenol and 7.0 ml H2SO4 were mixed with constant stirring in a glass vessel, and then kept in a water bath at 40 ℃. After cooling to room temperature for 20 min, the absorbance values were recorded by the UV-2501 PC spectrometer at the wavelength range of 485 nm. The polysaccharide content in Curcuma wenyujin were 3.21%, 3.23%, 3.20%, 3.18~/0, 3.22% and 2.38%, respectively. All results showed that this method was adequate, valid and applicable, may be applied to the determination of other bacterial polysaccharide as well.
基金the support of the National Natural Science Foundation of China(Nos.51674158,51604168 and 51504142)the Natural Science Foundation of Shandong Province(No.ZR2016EEQ18)+2 种基金the SDUST Research Fund(No.2015JQJH105)the Qingdao Postdoctoral Applied Research Project(No.2015204)the Taishan Scholar Talent Team Support Plan for Advantaged&Unique Discipline Areas
文摘In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorption/desorption device. Based on the characteristics of gas desorption from coal samples, we proposed a direct fitting method for measurement of gas content in coalbed, analyzed the effects of sampling time on the measurement results and determined the reasonable sampling time of coal samples with different metamorphic grades at different gas adsorption pressure at equilibrium. The results show that (1)the error of gas contents obtained using the direct fitting method relative to that obtained using indirect method is less than 10%, which meets the actual on-site requirements and verifies the feasibility of the direct fitting method;(2) when the relative error is controlled within ±10%, the reasonable sampling time of coal samples is linearly related to the gas adsorption pressure at equilibrium;(3) the reasonable sampling time of coal samples with the same metamorphic grade exhibits a shortening trend with increasing gas adsorption pressure at equilibrium;(4) for coal samples with similar gas adsorption pressure at equilibrium, the reasonable sampling time of coal samples displays a shortening trend with increasing metamorphic grade. Overall, the study provides a basis for improving the measurement accuracy of gas content in coalbed.