Over the Asian continent,high aerosol loading is critical to ensure the high accuracy of CO_2 retrieval in the near infrared absorption band.Simulations were performed to explore the effect of light path modification ...Over the Asian continent,high aerosol loading is critical to ensure the high accuracy of CO_2 retrieval in the near infrared absorption band.Simulations were performed to explore the effect of light path modification by aerosol son the atmospheric CO_2 near infrared band(6140-6270 cm^(-1)).The Vector LInearized Discrete Ordinate Radiative Transfer(VLIDORT) model and the Line-By-Line Radiative Transfer Model(LBLRTM) were used for forward calculations.The U.S.standard atmosphere was used for atmospheric profiles.The results indicate that the aerosols caused similar effects to increases in CO_2 in the planetary boundary layer and became more significant with aerosol layer rising while aerosol optical depth was 0.1.This effect will cause an over estimation of the CO_2 mixing ratio in the retrieval process and an under estimation in the aerosol layer.The results also indicate that the effect of urban and industrial aerosols is smaller than that of non-absorbing and dust aerosols because of the nearly constant absorption properties in the near infrared band.展开更多
A dual-gas sensor system is developed for CO and CO_2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing(TDM) technique. A stepper motor based rotating system and a ...A dual-gas sensor system is developed for CO and CO_2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing(TDM) technique. A stepper motor based rotating system and a single-reflection spherical optical mirror are designed and adopted for realizing and enhancing dual-gas detection. Detailed measurements under static detection mode(without rotation) and dynamic mode(with rotation) are performed to study the performance of the sensor system for the two gas samples. The detection period is 7.9 s in one round of detection by scanning the two detectors. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 3.0 parts per million(ppm) in volume and 2.6 ppm for CO and CO_2, respectively, and those under dynamic operation are 9.4 ppm and 10.8 ppm for CO and CO_2, respectively. The reported sensor has potential applications in various fields requiring CO and CO_2 detection such as in the coal mine.展开更多
Traumatic retropharyngeal hematoma is a rare condition and may be lethal in some cases. In patients with this condition, the absence of a vertebral fracture or a major vascular injury is extremely rare. We present the...Traumatic retropharyngeal hematoma is a rare condition and may be lethal in some cases. In patients with this condition, the absence of a vertebral fracture or a major vascular injury is extremely rare. We present the case of a 92-year-old man who hit his forehead by slipping on the floor in his house. He had no symptoms at the time; however, he experienced throat pain and dyspnea at 6 hours after the injury. On arrival, he complained of severe dyspnea; therefore, an emergency endotracheal intubation was performed. A lateral neck roentgenogram after intubation showed dilatation of the retropharyngeal and retrotracheal space and no evidence of a cervical vertebral fracture. Cervical computed tomography (CT) with contrast medium revealed a massive hematoma extending from the retropharyngeal to the superior mediastinal space but no evidence of contrast medium extravasation or a vertebral fracture. However, sagittal magnetic resonance imaging (MRI) revealed an anterior longitudinal ligament (C4-5 levels) injury. We determined that the cause of the hematoma was an anterior longitudinal ligament injury and a minor vascular injury around the injured ligament. Therefore, we recommend that patients with retropharyngeal hematoma undergo sagittal cervical MRI when roentgenography and CT reveal no evidenee of injury.展开更多
基金funded by the Strategic Priority Research Program-Climate Change:Carbon Budget and Relevant Issues (Grant No. XDA05040200)the National High Techonology Research and Development Program of China (863 Program,Grant No. 2011AA12A104)
文摘Over the Asian continent,high aerosol loading is critical to ensure the high accuracy of CO_2 retrieval in the near infrared absorption band.Simulations were performed to explore the effect of light path modification by aerosol son the atmospheric CO_2 near infrared band(6140-6270 cm^(-1)).The Vector LInearized Discrete Ordinate Radiative Transfer(VLIDORT) model and the Line-By-Line Radiative Transfer Model(LBLRTM) were used for forward calculations.The U.S.standard atmosphere was used for atmospheric profiles.The results indicate that the aerosols caused similar effects to increases in CO_2 in the planetary boundary layer and became more significant with aerosol layer rising while aerosol optical depth was 0.1.This effect will cause an over estimation of the CO_2 mixing ratio in the retrieval process and an under estimation in the aerosol layer.The results also indicate that the effect of urban and industrial aerosols is smaller than that of non-absorbing and dust aerosols because of the nearly constant absorption properties in the near infrared band.
基金supported by the National Key R&D Program of China(Nos.2016YFD0700101 and 2016YFC0303902)the National Natural Science Foundation of China(Nos.61775079,61627823 and 61307124)+3 种基金the Science and Technology Planning Project of Guangdong Province,China(No.2017A020216011)the Science and Technology Development Program of Jilin Province,China(No.20140307014SF)the Industrial Innovation Program of Jilin Province,China(No.2017C027)Changchun Municipal Science and Technology Bureau,China(No.14KG022)
文摘A dual-gas sensor system is developed for CO and CO_2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing(TDM) technique. A stepper motor based rotating system and a single-reflection spherical optical mirror are designed and adopted for realizing and enhancing dual-gas detection. Detailed measurements under static detection mode(without rotation) and dynamic mode(with rotation) are performed to study the performance of the sensor system for the two gas samples. The detection period is 7.9 s in one round of detection by scanning the two detectors. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 3.0 parts per million(ppm) in volume and 2.6 ppm for CO and CO_2, respectively, and those under dynamic operation are 9.4 ppm and 10.8 ppm for CO and CO_2, respectively. The reported sensor has potential applications in various fields requiring CO and CO_2 detection such as in the coal mine.
文摘Traumatic retropharyngeal hematoma is a rare condition and may be lethal in some cases. In patients with this condition, the absence of a vertebral fracture or a major vascular injury is extremely rare. We present the case of a 92-year-old man who hit his forehead by slipping on the floor in his house. He had no symptoms at the time; however, he experienced throat pain and dyspnea at 6 hours after the injury. On arrival, he complained of severe dyspnea; therefore, an emergency endotracheal intubation was performed. A lateral neck roentgenogram after intubation showed dilatation of the retropharyngeal and retrotracheal space and no evidence of a cervical vertebral fracture. Cervical computed tomography (CT) with contrast medium revealed a massive hematoma extending from the retropharyngeal to the superior mediastinal space but no evidence of contrast medium extravasation or a vertebral fracture. However, sagittal magnetic resonance imaging (MRI) revealed an anterior longitudinal ligament (C4-5 levels) injury. We determined that the cause of the hematoma was an anterior longitudinal ligament injury and a minor vascular injury around the injured ligament. Therefore, we recommend that patients with retropharyngeal hematoma undergo sagittal cervical MRI when roentgenography and CT reveal no evidenee of injury.