An optical fiber magnetic field sensor for the dual-parameter simultaneous measurement is proposed and demonstrated. The sensor head is constructed by a peanut-shape structure and long period fiber grating(LPFG) coate...An optical fiber magnetic field sensor for the dual-parameter simultaneous measurement is proposed and demonstrated. The sensor head is constructed by a peanut-shape structure and long period fiber grating(LPFG) coated by magnetic fluid(MF). The external magnetic field intensity can be measured by the variation of characteristic wavelength(Dip1 and Dip2) in interference spectrum since the effective refractive index of MF changes with external magnetic field intensity. When the external magnetic field intensity changes from 0 mT to 20 mT, the magnetic field sensitivities of Dip1 and Dip2 are -0.064 nm/mT and -0.041 nm/mT, respectively. Experimental results show that the temperature sensitivities of the Dip1 and Dip2 are 0.233 nm/℃ and 0.186 nm/°C, respectively. Therefore, the simultaneous measurement of the magnetic field intensity and temperature is demonstrated based on the sensitive matrix. It has some potential applications in aerospace, environmental monitoring and medical sensing fields.展开更多
The gas-sensitive film coated π-phase-shifted long-period fiber grating(LPFG),consisting of two same long-period fiber gratings cascaded by a regular fiber with length of half of the grating period,is proposed for ga...The gas-sensitive film coated π-phase-shifted long-period fiber grating(LPFG),consisting of two same long-period fiber gratings cascaded by a regular fiber with length of half of the grating period,is proposed for gas sensing.The sensitivity of the sensor is defined by the change rate of the transmission at specific wavelength with respect to the film refractive index.The qualitative and numerical analyses show that to get a high sensitivity,the optimal coupling strength of each long-period fiber grating is √2 π/4.With this coupling strength,the longer the grating is,the higher sensitivity the sensor has.By choosing appropriate grating period,a high sensitivity for the film with a certain refractive index and thickness can be attained.展开更多
基金supported by the National High Technology Research and Development Program of China(863 Program)(No.2013AA014200)the National Natural Science Foundation of China(No.11444001)the Municipal Natural Science Foundation of Tianjin(No.14JCYBJC16500)
文摘An optical fiber magnetic field sensor for the dual-parameter simultaneous measurement is proposed and demonstrated. The sensor head is constructed by a peanut-shape structure and long period fiber grating(LPFG) coated by magnetic fluid(MF). The external magnetic field intensity can be measured by the variation of characteristic wavelength(Dip1 and Dip2) in interference spectrum since the effective refractive index of MF changes with external magnetic field intensity. When the external magnetic field intensity changes from 0 mT to 20 mT, the magnetic field sensitivities of Dip1 and Dip2 are -0.064 nm/mT and -0.041 nm/mT, respectively. Experimental results show that the temperature sensitivities of the Dip1 and Dip2 are 0.233 nm/℃ and 0.186 nm/°C, respectively. Therefore, the simultaneous measurement of the magnetic field intensity and temperature is demonstrated based on the sensitive matrix. It has some potential applications in aerospace, environmental monitoring and medical sensing fields.
基金supported by the National Natural Science Foundation of China (No.60777035)the Scientific Research Key Project Fund of the Ministry of Education (No.208040)the Shanghai Leading Academic Discipline Project (No.T0501)
文摘The gas-sensitive film coated π-phase-shifted long-period fiber grating(LPFG),consisting of two same long-period fiber gratings cascaded by a regular fiber with length of half of the grating period,is proposed for gas sensing.The sensitivity of the sensor is defined by the change rate of the transmission at specific wavelength with respect to the film refractive index.The qualitative and numerical analyses show that to get a high sensitivity,the optimal coupling strength of each long-period fiber grating is √2 π/4.With this coupling strength,the longer the grating is,the higher sensitivity the sensor has.By choosing appropriate grating period,a high sensitivity for the film with a certain refractive index and thickness can be attained.