期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
等效电路模型在漂移管直线加速器场稳定性调制中的应用 被引量:1
1
作者 冯来文 傅世年 +1 位作者 刘华昌 李阿红 《强激光与粒子束》 EI CAS CSCD 北大核心 2014年第8期286-290,共5页
漂移管直线加速器(DTL)通过采用杆耦合器加速结构,实现加速电场的稳定性。为了分析电场稳定性的调制机理,简要说明DTL的腔体结构,并对其进行集总参数的等效模拟,给出等效电路分布。最后着重对耦合杆与漂移管之间相互作用的等效电容进行... 漂移管直线加速器(DTL)通过采用杆耦合器加速结构,实现加速电场的稳定性。为了分析电场稳定性的调制机理,简要说明DTL的腔体结构,并对其进行集总参数的等效模拟,给出等效电路分布。最后着重对耦合杆与漂移管之间相互作用的等效电容进行了仿真研究。针对上述电路分布,采用电路理论分析了高频场扰动及稳定性的实现机理。通过将稳定结构下的等效电容求解结果与该电容的模拟仿真值进行比较,得出稳定状态下的耦合杆与漂移管之间间隙取值的合理区间。最后通过对不同调节条件下的扰动电场进行仿真分析,一定程度上验证了结论的正确性。 展开更多
关键词 漂移管直线加速 杆耦合器 周期性加速结构 等效电路 稳定性
下载PDF
Probabilistic Seismic Hazard Assessment for Jamaica
2
作者 Walter Salazar Lyndon Brown Garth Mannette 《Journal of Civil Engineering and Architecture》 2013年第9期1118-1140,共23页
A probabilistic seismic hazard analysis was performed to generate seismic hazard maps for Jamaica. The analysis was then conducted using a standard logic-tree approach that allowed systematically taking into account t... A probabilistic seismic hazard analysis was performed to generate seismic hazard maps for Jamaica. The analysis was then conducted using a standard logic-tree approach that allowed systematically taking into account the model-based (i.e., epistemic) uncertainty and its influence on the computed ground motion parameters. Hazard computations have been performed using a grid of sites with a space of 0.05 degrees. Two different computation methodologies have been adopted: the standard approach based on the definition of appropriate seismogenic sources and the zone-free approach, which overcomes the ambiguities related with the definition of the seismic sources solely reflecting the characteristics of the earthquake catalogue. A comprehensive and updated earthquake catalogue for Jamaica has been compiled for the years 1551-2010 and new empirical relationships amongst magnitudes Mze-Ms and Mw-mb have been developed for the region. Uniform hazard spectra and their uncertainty have been calculated for the horizontal component of ground motion for rock site conditions and five return periods (95, 475, 975, 2,475 and 4,975 years) and spectral accelerations for 34 structural periods ranging from 0 to 3 s, and 5% of critical damping. The spectral accelerations have been calculated to allow the definition of seismic hazard in Jamaica according to the International Building Code 2012. The disaggregation analysis for Kingston Metropolitan Area suggests that the magnitude-distance pair that contributes most to the hazard corresponds to events with M 7.8 and M 7.0 in the Enriquillo Plantain Garden Fault and the Jamaican Faults at a distance of 28 km and 18 km for short and long period structures respectively corresponding to 2,475 years return period. However, for long period structures, a substantial contribution is found for a M 8.2 at a distance of 198 km in the Oriente Fault Zone. 展开更多
关键词 Earthquake catalogue GMPE's (ground motion prediction equations) seismic hazard response spectrum disaggregationanalysis.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部