期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
气管导管咬口器的使用对预防非计划性拔管的临床护理效果分析 被引量:1
1
作者 吴玉珊 陈玉叶 刘芬 《哈尔滨医药》 2020年第3期295-296,共2页
目的观察和研究气管导管咬口器的使用对预防非计划性拔管的临床护理。方法选取60例气管插管患者,随机分为实验组(n=30)和对照组(n=30),实验组采用气管导管咬口器固定气管导管,对照组采用改良式注射器固定气管导管,采用同样的治疗手段和... 目的观察和研究气管导管咬口器的使用对预防非计划性拔管的临床护理。方法选取60例气管插管患者,随机分为实验组(n=30)和对照组(n=30),实验组采用气管导管咬口器固定气管导管,对照组采用改良式注射器固定气管导管,采用同样的治疗手段和护理手段,观察对比两组患者插管后的咬堵管、脱管,口腔清洁度,口腔舒适度,口腔黏膜损伤的例数,以此评价气管导管咬口器的作用。结果实验组的咬堵管、脱管、口腔黏膜损伤的例数明显少于对照组(P<0.05),口腔清洁度,口腔舒适度,护理满意度明显高于对照组(P<0.05)。结论气管导管咬口器对预防非计划性拔管具有显著作用,可明显改善患者的舒适度和满意度,临床护理工作可以借鉴。 展开更多
关键词 气管导管 咬口器 非计划性拔管 护理 插管
下载PDF
Influence of occlusal splint thickness on the position of mandible
2
作者 陈永进 长岛正 野首孝祠 《Journal of Medical Colleges of PLA(China)》 CAS 2005年第1期37-42,共6页
Objective: To investigate the influence of occlusal splint thickness on mandibular movement. Methods: Stabilization occlusal splints of 3, 5 and 7 mm thickness were respectively used during clenching from light contac... Objective: To investigate the influence of occlusal splint thickness on mandibular movement. Methods: Stabilization occlusal splints of 3, 5 and 7 mm thickness were respectively used during clenching from light contact in intercuspal position and the movement of condyles and incisor point were recorded in 5 healthy subjects. Results:The condyles moved anteriorly and superiorly without wearing occlusal splint. When wearing the occlusal splints the condyles displaced anteriorly and inferiorly. The distance of displacement increased gradually with raising the thickness of splint, though the significant difference was just found in right condyle in superior- inferior movement. The condyles went again on a path of anterior and superior direction when subjects clenched from the displaced position. In right condyle the displacement was significantly greater at 7 mm splint than that at 3 mm splint both in anterior-posterior and inferior-superior direction, while in left condyle only in anterior-posterior direction. Meanwhile, the incisal point movement was larger at 7 mm splint than at 3 mm splint in inferior-superior direction. In tapping movement there were no significant differences in condyle movement between the different thickness of occlusal splint. However, the coefficient of variation in total cycle time was the greatest when wearing the splint of 7 mm. Conclusion: Occlusal splint of 7 mm has greater effect than that of 3 mm on condyle movement, but no obvious difference with occlusal splint of 5 mm. When occlusal splint of 7 mm is inserted, the stability of condyle might be influenced during tapping movement. 展开更多
关键词 occlusal splint mandibular movement condyle position
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部