A compact pneumatic pulse-jet pump with a Venturi-like reverse flow diverter,which consists of a nozzle and diffuser,is designed for lifting and transporting a hazardous fluid through a narrow mounting hole.The pumpin...A compact pneumatic pulse-jet pump with a Venturi-like reverse flow diverter,which consists of a nozzle and diffuser,is designed for lifting and transporting a hazardous fluid through a narrow mounting hole.The pumping performance for a liquid mixture or a liquid-solid mixture is examined in terms of the effects of liquid viscosity,particle mass concentration,lifting height,and compression pressure.Results reveal that the pumping performance of the compact pneumatic pulse-jet pump is controlled by jet inertia and the flow resistance of the riser tube positioned after the diffuser.The capacity of the compact pneumatic pulse-jet pump increases with compression pressure and decreases with liquid viscosity.However,even for a liquid mixture with a high viscosity of 7.38 mPa·s,a pumping capacity of 170.7 L·h-1 was observed.For a liquid mixture,two dimensionless indices of performance were found to be the ratio of Euler numbers Euout/EuDV and the suction factor q.As the liquid-solid mixture was lifted to elevation of 6.74 m by the compact pump,the particle size distributions of the liquid-solid mixture in the tank and from the riser tube outlet were determined by a particle size analyzer and found to coincide well.展开更多
AIM: To explore the feasibility of a water-jet hybrid knife to facilitate wedge hepatic resection using a natural orifice transluminal endoscopic surgery (NOTES) approach in a non-survival porcine model. METHODS: The ...AIM: To explore the feasibility of a water-jet hybrid knife to facilitate wedge hepatic resection using a natural orifice transluminal endoscopic surgery (NOTES) approach in a non-survival porcine model. METHODS: The Erbe Jet2 water-jet system allows a needleless, tissue-selective hydro-dissection with a pre-selected pressure. Using this system, wedge hepatic resection was performed through three natural routes (trans-anal, trans-vaginal and trans-umbilical) in three female pigs weighing 35 kg under general anesthesia. Entry into the peritoneal cavity was via a 15-mm incision using a hook knife. The targeted liver segment was marked by an APC probe, followed by wedge hepatic resection performed using a water-jet hybrid knife with the aid of a 4-mm transparent distance soft cap mounted onto the tip of the endoscope for holding up the desired plane. The exposed vascular and ductal structures were clipped with Endoclips. Hemostasis was applied to the bleeding cut edges of the liver parenchyma by electrocautery. After the procedure, the incision site was left open, and the animal was euthanized followed by necropsy. RESULTS: Using the Erbe Jet2 water-jet system, trans-anal and trans-vaginal wedge hepatic resection was successfully performed in two pigs without laparoscopic assistance. Trans-umbilical attempt failed due to an unstable operating platform. The incision for peritoneal entry took 1 min, and about 2 h was spent on excision of the liver tissue. The intra-operative blood loss ranged from 100 to 250 mL. Microscopically, the hydro-dissections were relatively precise and gentle, preserving most vessels. CONCLUSION: The Erbe Jet2 water-jet system can safely accomplish non-anatomic wedge hepatic resection in NOTES, which deserves further studies to shorten the dissection time.展开更多
An algebraic model of turbulence,involving buoyancy forces,is used for calculating velocity and temperature fields in plane turbulent vertical jets in a non-homogeneous stagnant medium.A new approach to the solution o...An algebraic model of turbulence,involving buoyancy forces,is used for calculating velocity and temperature fields in plane turbulent vertical jets in a non-homogeneous stagnant medium.A new approach to the solution of the governing system of partial differential equations (continuity,conservation of momentum,heat (buoyancy), turbulent kinetic energy,dissipation rate and mean quadratic temperature fluctuation) is suggested which is based on the introduction of mathematical variables.Comparison is made between the results of the present calculations with experimental and numerical data of other authors.展开更多
文摘A compact pneumatic pulse-jet pump with a Venturi-like reverse flow diverter,which consists of a nozzle and diffuser,is designed for lifting and transporting a hazardous fluid through a narrow mounting hole.The pumping performance for a liquid mixture or a liquid-solid mixture is examined in terms of the effects of liquid viscosity,particle mass concentration,lifting height,and compression pressure.Results reveal that the pumping performance of the compact pneumatic pulse-jet pump is controlled by jet inertia and the flow resistance of the riser tube positioned after the diffuser.The capacity of the compact pneumatic pulse-jet pump increases with compression pressure and decreases with liquid viscosity.However,even for a liquid mixture with a high viscosity of 7.38 mPa·s,a pumping capacity of 170.7 L·h-1 was observed.For a liquid mixture,two dimensionless indices of performance were found to be the ratio of Euler numbers Euout/EuDV and the suction factor q.As the liquid-solid mixture was lifted to elevation of 6.74 m by the compact pump,the particle size distributions of the liquid-solid mixture in the tank and from the riser tube outlet were determined by a particle size analyzer and found to coincide well.
文摘AIM: To explore the feasibility of a water-jet hybrid knife to facilitate wedge hepatic resection using a natural orifice transluminal endoscopic surgery (NOTES) approach in a non-survival porcine model. METHODS: The Erbe Jet2 water-jet system allows a needleless, tissue-selective hydro-dissection with a pre-selected pressure. Using this system, wedge hepatic resection was performed through three natural routes (trans-anal, trans-vaginal and trans-umbilical) in three female pigs weighing 35 kg under general anesthesia. Entry into the peritoneal cavity was via a 15-mm incision using a hook knife. The targeted liver segment was marked by an APC probe, followed by wedge hepatic resection performed using a water-jet hybrid knife with the aid of a 4-mm transparent distance soft cap mounted onto the tip of the endoscope for holding up the desired plane. The exposed vascular and ductal structures were clipped with Endoclips. Hemostasis was applied to the bleeding cut edges of the liver parenchyma by electrocautery. After the procedure, the incision site was left open, and the animal was euthanized followed by necropsy. RESULTS: Using the Erbe Jet2 water-jet system, trans-anal and trans-vaginal wedge hepatic resection was successfully performed in two pigs without laparoscopic assistance. Trans-umbilical attempt failed due to an unstable operating platform. The incision for peritoneal entry took 1 min, and about 2 h was spent on excision of the liver tissue. The intra-operative blood loss ranged from 100 to 250 mL. Microscopically, the hydro-dissections were relatively precise and gentle, preserving most vessels. CONCLUSION: The Erbe Jet2 water-jet system can safely accomplish non-anatomic wedge hepatic resection in NOTES, which deserves further studies to shorten the dissection time.
文摘An algebraic model of turbulence,involving buoyancy forces,is used for calculating velocity and temperature fields in plane turbulent vertical jets in a non-homogeneous stagnant medium.A new approach to the solution of the governing system of partial differential equations (continuity,conservation of momentum,heat (buoyancy), turbulent kinetic energy,dissipation rate and mean quadratic temperature fluctuation) is suggested which is based on the introduction of mathematical variables.Comparison is made between the results of the present calculations with experimental and numerical data of other authors.