In high-resolution cone-beam computed tomography (CBCT) using the flat-panel detector, imperfect or defect detector elements cause ring artifacts due to the none-uniformity of their X-ray response. They often distur...In high-resolution cone-beam computed tomography (CBCT) using the flat-panel detector, imperfect or defect detector elements cause ring artifacts due to the none-uniformity of their X-ray response. They often disturb the image quality. A dedicated fitting correction method for high-resolution micro-CT is presented. The method converts each elementary X-ray response curve to an average one, and eliminates response inconsistency among pixels. Other factors of the method are discussed, such as the correction factor variability by different sampling frames and nonlinear factors over the whole spectrum. Results show that the noise and artifacts are both reduced in reconstructed images展开更多
The sound ray tracing method can achieve higher accuracy in determining depths and plan positions with multibeam echo sounding system. In data processing, actual sound speed profile must be used in the method. However...The sound ray tracing method can achieve higher accuracy in determining depths and plan positions with multibeam echo sounding system. In data processing, actual sound speed profile must be used in the method. However, the method is too complicated. In order to overcome the shortcoming, this paper presents a new method, the position correction method. Two situations are considered in the new method, namely, change of sound velocity keeps constant gradient in whole water column (including N layers) or in different water layer.展开更多
For the multisensor system with correlated measurement noises and unknown noise statistics, based on the solution of the matrix equations for correlation function, the on-line estimators of the noise variances and cro...For the multisensor system with correlated measurement noises and unknown noise statistics, based on the solution of the matrix equations for correlation function, the on-line estimators of the noise variances and cross-covariances is obtained. Further, a self-tuning weighted measurement fusion Kalman filter is presented, based on the Riccati equation. By the Dynamic Error System Analysis (DESA) method, it rigorously proved that the presented self-tuning weighted measurement fusion Kalman filter converges to the optimal weighted measurement fusion steady-state Kalman filter in a realization or with probability one, so that it has asymptotic global optimality. A simulation example for a target tracking system with 3-sensor shows that the presented self-tuning measurement fusion Kalman fuser converges to the optimal steady-state measurement fusion Kalman fuser.展开更多
Calibration of magnetometer is an essential part to obtain high measurement precision.However,the existing calibration methods are basically the calibration of all attitudes,which means tough work when the magnetomete...Calibration of magnetometer is an essential part to obtain high measurement precision.However,the existing calibration methods are basically the calibration of all attitudes,which means tough work when the magnetometer is applied in strapdown inertial navigation system(SINS).So a quick,easy and effective calibration algorithm is developed based on the ellipsoid constraint to calibrate magnetometers.In this paper,the measuring principle and error characteristic of the magnetometer are analysed to study its magnetic interference.During the process,a magnetometer calibration model is set up to convert the calibration to ellipsoid fitting based on the characteristic of hard magnetic interference and soft magnetic interference.Then the algorithm is tested by mimic experiment.The result shows that measurement precision is improved after the calibration,and then the magnetometer is installed in a control cabin of an underwater robot which is designed and developed by us,and actual magnetometer calibration experiments are conducted to further verify the validity of the algorithm.展开更多
基金Supported by the National Basic Research Program of China ("973"Program)(2006CB601201)~~
文摘In high-resolution cone-beam computed tomography (CBCT) using the flat-panel detector, imperfect or defect detector elements cause ring artifacts due to the none-uniformity of their X-ray response. They often disturb the image quality. A dedicated fitting correction method for high-resolution micro-CT is presented. The method converts each elementary X-ray response curve to an average one, and eliminates response inconsistency among pixels. Other factors of the method are discussed, such as the correction factor variability by different sampling frames and nonlinear factors over the whole spectrum. Results show that the noise and artifacts are both reduced in reconstructed images
文摘The sound ray tracing method can achieve higher accuracy in determining depths and plan positions with multibeam echo sounding system. In data processing, actual sound speed profile must be used in the method. However, the method is too complicated. In order to overcome the shortcoming, this paper presents a new method, the position correction method. Two situations are considered in the new method, namely, change of sound velocity keeps constant gradient in whole water column (including N layers) or in different water layer.
基金Supported by the National Natural Science Foundation of China (No.60874063)Science and Technology Research Foundation of Heilongjiang Education Department (No.11521214)Open Fund of Key Laboratory of Electronics Engineering, College of Heilongjiang Province (Heilongjiang University)
文摘For the multisensor system with correlated measurement noises and unknown noise statistics, based on the solution of the matrix equations for correlation function, the on-line estimators of the noise variances and cross-covariances is obtained. Further, a self-tuning weighted measurement fusion Kalman filter is presented, based on the Riccati equation. By the Dynamic Error System Analysis (DESA) method, it rigorously proved that the presented self-tuning weighted measurement fusion Kalman filter converges to the optimal weighted measurement fusion steady-state Kalman filter in a realization or with probability one, so that it has asymptotic global optimality. A simulation example for a target tracking system with 3-sensor shows that the presented self-tuning measurement fusion Kalman fuser converges to the optimal steady-state measurement fusion Kalman fuser.
基金Supported by the National High Technology Research and Development Programme of China(No.2011AA04201)
文摘Calibration of magnetometer is an essential part to obtain high measurement precision.However,the existing calibration methods are basically the calibration of all attitudes,which means tough work when the magnetometer is applied in strapdown inertial navigation system(SINS).So a quick,easy and effective calibration algorithm is developed based on the ellipsoid constraint to calibrate magnetometers.In this paper,the measuring principle and error characteristic of the magnetometer are analysed to study its magnetic interference.During the process,a magnetometer calibration model is set up to convert the calibration to ellipsoid fitting based on the characteristic of hard magnetic interference and soft magnetic interference.Then the algorithm is tested by mimic experiment.The result shows that measurement precision is improved after the calibration,and then the magnetometer is installed in a control cabin of an underwater robot which is designed and developed by us,and actual magnetometer calibration experiments are conducted to further verify the validity of the algorithm.