Central composite design (CCD), the most popular design ofresponse surface methodology (RSM), was employed to investigate theeffect of total organic carbon (TOC) ratio of high molecular weightorganic matter (HMW) to l...Central composite design (CCD), the most popular design ofresponse surface methodology (RSM), was employed to investigate theeffect of total organic carbon (TOC) ratio of high molecular weightorganic matter (HMW) to low molecular weight organic matter (LMW),the LMW strength and molar ratio of hydrogen peroxide to ferrous ionon landfill leachate treatment by Fenton process. Based on theexperimental data, a response surface quadratic model in terms ofactual factors was obtained through analysis of variance (ANOVA).展开更多
The sludge was landfilled after solidification/stabilization treatment. This technology can solve the problem of much sludge treatment. But the study on engineering application is less common. There is a lack of corre...The sludge was landfilled after solidification/stabilization treatment. This technology can solve the problem of much sludge treatment. But the study on engineering application is less common. There is a lack of corresponding research results about equipment, process and treatment effect. According to the above problems, this paper discusses the treatment process combining with sludge solidification/stabilization landfill field in Fuyong Town in Shenzhen City. Furthermore, the strength, moisture content, environmental indexes of treated sludge in field test was carried out in order to monitor the treatment effect. The results showed that the sludge solidification/stabilization equipment can meet the need of large-scale engineering application and the treatment process is relatively simple and the solidified sludge can meet the need of landfill.展开更多
The objectives of this study are to determine the characteristics of leachates generated from landfill lysimeters of municipal solid waste. Two lysimeters with diameter and height of 0.70 and 2.40 m, respectively, wer...The objectives of this study are to determine the characteristics of leachates generated from landfill lysimeters of municipal solid waste. Two lysimeters with diameter and height of 0.70 and 2.40 m, respectively, were prepared. The lysimeters were operated with and without leachate recirculation. The leachate produced were quantified and characterised every day for the quantity, pH and ORP (oxidation reduction potential). Meanwhile, the BOD and COD parameters were characterised every once week. Based on the data of experimental results that the lysimeter with a recirculation gave positive effects on the degradation of waste in landfills, that is the degradation process becomes faster. This is indicated by the quantity and quality of leachate generated. The lyisimeter conducted with recirculation of leachate shew the quantity of leachate generated larger than the lysimeter without recirculation. While the quality of the leachate includes pH, ORP, made it shown that the degradation process is faster. These results operations, especially for young waste. BOD and COD indicate that leachate recirculation on lysismeter suggest that leachate recirculation can be performed on landfills展开更多
基金Supported by the Delaware Solid Waste Authority, Dover DE, USA and China Scholarship Council (No. 97842039).
文摘Central composite design (CCD), the most popular design ofresponse surface methodology (RSM), was employed to investigate theeffect of total organic carbon (TOC) ratio of high molecular weightorganic matter (HMW) to low molecular weight organic matter (LMW),the LMW strength and molar ratio of hydrogen peroxide to ferrous ionon landfill leachate treatment by Fenton process. Based on theexperimental data, a response surface quadratic model in terms ofactual factors was obtained through analysis of variance (ANOVA).
文摘The sludge was landfilled after solidification/stabilization treatment. This technology can solve the problem of much sludge treatment. But the study on engineering application is less common. There is a lack of corresponding research results about equipment, process and treatment effect. According to the above problems, this paper discusses the treatment process combining with sludge solidification/stabilization landfill field in Fuyong Town in Shenzhen City. Furthermore, the strength, moisture content, environmental indexes of treated sludge in field test was carried out in order to monitor the treatment effect. The results showed that the sludge solidification/stabilization equipment can meet the need of large-scale engineering application and the treatment process is relatively simple and the solidified sludge can meet the need of landfill.
文摘The objectives of this study are to determine the characteristics of leachates generated from landfill lysimeters of municipal solid waste. Two lysimeters with diameter and height of 0.70 and 2.40 m, respectively, were prepared. The lysimeters were operated with and without leachate recirculation. The leachate produced were quantified and characterised every day for the quantity, pH and ORP (oxidation reduction potential). Meanwhile, the BOD and COD parameters were characterised every once week. Based on the data of experimental results that the lysimeter with a recirculation gave positive effects on the degradation of waste in landfills, that is the degradation process becomes faster. This is indicated by the quantity and quality of leachate generated. The lyisimeter conducted with recirculation of leachate shew the quantity of leachate generated larger than the lysimeter without recirculation. While the quality of the leachate includes pH, ORP, made it shown that the degradation process is faster. These results operations, especially for young waste. BOD and COD indicate that leachate recirculation on lysismeter suggest that leachate recirculation can be performed on landfills