Based on microscope and image processing, a new method of auto tool setting for micro milling was presented. Firstly, a realtime image of tool setting area was obtained by microscope and CCD camera, then image process...Based on microscope and image processing, a new method of auto tool setting for micro milling was presented. Firstly, a realtime image of tool setting area was obtained by microscope and CCD camera, then image processing was carried out on this image and the gap between the tool and workpiece was calculated. The gap measurement was sent to motion controlling card to make the tool approach to the surface of workpiece. These steps were repeated until the gap is zero, which means that tool setting was finished. Moreover, a reliability verification test was conducted. Results indicated that the precision of tool setting is satisfactory.展开更多
Objective: The aim of this work was to quantify the extent of set-up errors to conduct a quality assurance (QA) aspect of treatment delivery, verification of the treatment field's position on different days using ...Objective: The aim of this work was to quantify the extent of set-up errors to conduct a quality assurance (QA) aspect of treatment delivery, verification of the treatment field's position on different days using electronic portal. Methods: This study was carried out on 12 patients, treated for pelvis tumor; and total of 240 images obtained by electronic portal image device (EPID) were analyzed. The EPIs acquire using EPID attached to the Siemens linear accelerator. The anatomy match- ing software (Theraview) was used and displacement in two dimensions were noted for each treatment field to study patient setup errors. Results: The percentages of mean deviations less than 5 mm in X direction were 65% & 92%, from 5-10 mm were 31% & 19% and more than 10 mm were 11% & 9% forNP and lateral direction respectively. The percentages of mean deviations less than 5 mm in Y direction were 65% & 63%, from 5-10 mm were 33% & 28% and more than 10 mm were 22% & 29%. The mean deviations in 2D-vector errors were 〈 5 mm in 47% and 46%, 5-10 mm in 36% and 37% and 〉 10 mm in 37% and 37% of images in the NP and lateral direction respectively. Conclusion: The results revealed that the ranges of set up errors are immobilization method to improve reproducibility. The observed variations were not within the limits..展开更多
基金Supported by National Natural Science Foundation of China (No. 50935003)
文摘Based on microscope and image processing, a new method of auto tool setting for micro milling was presented. Firstly, a realtime image of tool setting area was obtained by microscope and CCD camera, then image processing was carried out on this image and the gap between the tool and workpiece was calculated. The gap measurement was sent to motion controlling card to make the tool approach to the surface of workpiece. These steps were repeated until the gap is zero, which means that tool setting was finished. Moreover, a reliability verification test was conducted. Results indicated that the precision of tool setting is satisfactory.
文摘Objective: The aim of this work was to quantify the extent of set-up errors to conduct a quality assurance (QA) aspect of treatment delivery, verification of the treatment field's position on different days using electronic portal. Methods: This study was carried out on 12 patients, treated for pelvis tumor; and total of 240 images obtained by electronic portal image device (EPID) were analyzed. The EPIs acquire using EPID attached to the Siemens linear accelerator. The anatomy match- ing software (Theraview) was used and displacement in two dimensions were noted for each treatment field to study patient setup errors. Results: The percentages of mean deviations less than 5 mm in X direction were 65% & 92%, from 5-10 mm were 31% & 19% and more than 10 mm were 11% & 9% forNP and lateral direction respectively. The percentages of mean deviations less than 5 mm in Y direction were 65% & 63%, from 5-10 mm were 33% & 28% and more than 10 mm were 22% & 29%. The mean deviations in 2D-vector errors were 〈 5 mm in 47% and 46%, 5-10 mm in 36% and 37% and 〉 10 mm in 37% and 37% of images in the NP and lateral direction respectively. Conclusion: The results revealed that the ranges of set up errors are immobilization method to improve reproducibility. The observed variations were not within the limits..