期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
图形视网膜电图在糖尿病视网膜病变诊断中的应用 被引量:2
1
作者 蒋克春 饶亚平 +3 位作者 邹涓 彭琦 庞春梅 王爱萍 《实用糖尿病杂志》 2007年第6期38-40,共3页
对正常对照者及糖尿病患者分别测P-ERG潜伏期ln25l、p50l、n95及其波幅an25、ap50、an75。结果:DM患者视网膜尚未出现病变时,P-ERG的潜伏期已延迟,随着视网膜病变的发生和发展,进一步延迟,但未达显著性差异。DR及各期波幅下降不显著。P-... 对正常对照者及糖尿病患者分别测P-ERG潜伏期ln25l、p50l、n95及其波幅an25、ap50、an75。结果:DM患者视网膜尚未出现病变时,P-ERG的潜伏期已延迟,随着视网膜病变的发生和发展,进一步延迟,但未达显著性差异。DR及各期波幅下降不显著。P-ERG的潜伏期及波幅与视力无关。结论:P-ERG可作为发现早期DR的检查工具,P-ERG潜伏期比波幅具更好的临床使用价值。 展开更多
关键词 糖尿病(DM) 糖尿病视网膜病(DR) 图形视网膜电图(p—erg)
下载PDF
图形视网膜电图和视觉诱发电位对检测高眼压和青光眼视功能损害的临床能力 被引量:2
2
作者 Parisi V. Miglior S. +1 位作者 Manni G. 曹绪胜(译) 《世界核心医学期刊文摘(眼科学分册)》 2006年第6期46-47,共2页
Objective: To assess the presence of normal or abnormal pattern electroretinogram (PERG) and visual evoked potential (VEP)-responses in patients with ocular hypertension or open-angle glaucoma (OAG). Design: Retrospec... Objective: To assess the presence of normal or abnormal pattern electroretinogram (PERG) and visual evoked potential (VEP)-responses in patients with ocular hypertension or open-angle glaucoma (OAG). Design: Retrospective,cross-sectional,case-control study. Participants: Eighty normal control subjects (mean age,51.77± 6.04 years; 80 eyes),68 ocular hypertension patients (mean age,51.58± 7.12; 68 eyes; intraocular pressure IOP < 18 mmHg under pharmacological treatment; Humphrey field analysis HFA 24/2 mean deviation MD >-2 decibels dB),and 84 OAG patients (mean age,52.77± 5.28; 84 eyes; IOP < 18 mmHg under pharmacological treatment; HFA24/2mean deviation between-2 and-23 dB)were enrolled. Methods: Simultaneous recording of PERGs and VEPs using high-contrast (80% ) 15 checkerboard stimuli reversed at the rate of 2 reversals per second. Main Outcome Measures: Pattern electroretinogram P50 and VEP P100 implicit times were considered delayed when exceeding the limit of mean values of controls plus 2 standard deviations (SDs). Pattern electroretinogram P50 to N95 and VEP N75 to P100 amplitudes were considered reduced when exceeding the limit of mean values of controls minus 2 SDs. Results: Pattern electroretinogram: P50 implicit times were delayed in 58 of 68 (85.30% ) ocular hypertension eyes and 83 of 84 (98.80% )OAG eyes; P50 toN95 amplitudes were reduced in 47 (69.12% ) ocular hypertension eyes and 84 (100% ) OAG eyes. Visual evoked potential: P100 implicit times were delayed in 58 (85.30% ) ocular hypertension eyes and 84 (100% ) OAG eyes; reduced N75 to P100 amplitudes were observed in 39 (57.35% ) ocular hypertension eyes and 73 (86.90% ) OAG eyes. Ocular hypertension eyes showed no significant correlations (Pearson test,P>0.01) between electrophysiological parameters and age,IOP before or under medical treatment,HFA,and corneal thickness values. Significant correlations (P<0.01) were observed in OAG eyes between electrophysiological results and HFA values. Pattern electroretinogram and VEP responses were normal in all control eyes. Conclusions: Combined PERG/VEP recordings identified a large percentage of ocular hypertension eyes with impairment of the innermost retinal layers,not withstanding normal optic disc morphology and normal HFA. In OAG eyes,PERG P50 to N95 amplitude and VEP P100 implicit time showed the highest sensitivity/specificity for the detection of a visual dysfunction. The presence of abnormal PERG and/or VEP responses did not allow a clearcut separation between ocular hypertension and OAG eyes. 展开更多
关键词 图形视网膜电图 视觉诱发电位 高眼压症 青光眼视功能损害 临床能力 p100潜伏期 正常对照组 潜伏期延长 检测 开角型青光眼
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部