穿墙机内风机转速波动技术分析
1
作者 金德武 《日用电器》 2023年第10期121-124,127,共5页
空调器内风机转速波动是一种常见现象,影响用户实际使用舒适性,必须要有效解决。其转速波动的原因主要有软件设计、硬件设计两方面,本文重点阐述引起转速波动的硬件设计方面原因,通过优化PCB板控制地和功率地走线、适当铺铜,加粗电源线... 空调器内风机转速波动是一种常见现象,影响用户实际使用舒适性,必须要有效解决。其转速波动的原因主要有软件设计、硬件设计两方面,本文重点阐述引起转速波动的硬件设计方面原因,通过优化PCB板控制地和功率地走线、适当铺铜,加粗电源线、地线走线,反馈信号采用单过孔,并将退耦电容移到靠近芯片口的位置等方案,有效地解决风机转速异常波动。 展开更多
关键词 转速波形 地走线 滤波
下载PDF
The influence of sea water velocity variation on seismic traveltimes,ray paths,and amplitude 被引量:9
2
作者 韩复兴 孙建国 王坤 《Applied Geophysics》 SCIE CSCD 2012年第3期319-325,361,362,共9页
The main factors affecting seismic exploration is the propagation velocity of seismic waves in the medium. In the past, during marine seismic data processing, the propagation velocity of sea water was generally taken ... The main factors affecting seismic exploration is the propagation velocity of seismic waves in the medium. In the past, during marine seismic data processing, the propagation velocity of sea water was generally taken as a constant 1500 m/s. However, for deep water exploration, the sound velocity varies with the season, time, location, water depth, ocean currents, and etc.. It also results in a layered velocity distribution, so there is a difference of seismic traveltime, ray paths, and amplitude, which affect the migration imaging results if sea water propagation velocity is still taken as constant for the propagation wavefield. In this paper, we will start from an empirical equation of seismic wave velocity in seawater with changes of temperature, salinity, and depth, consider the variation of their values, build a seawater velocity model, and quantitatively analyze the impact of seawater velocity variation on seismic traveltime, ray paths, and amplitude in the seawater velocity model. 展开更多
关键词 Sea water velocity TRAVELTIMES ray paths AMPLITUDE
下载PDF
Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
3
作者 许高雄 《Journal of Chongqing University》 CAS 2011年第2期78-83,共6页
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing... It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles. 展开更多
关键词 loop method single-phase earth fault short-circuit current distribution optical fiber composite overhead ground wire ordinary ground wire
下载PDF