Quantitative thickness estimation below tuning thickness is a great challenge in seismic exploration. Most studies focus on the thin-beds whose top and bottom reflection coefficients are of equal magnitude and opposit...Quantitative thickness estimation below tuning thickness is a great challenge in seismic exploration. Most studies focus on the thin-beds whose top and bottom reflection coefficients are of equal magnitude and opposite polarity. There is no systematic research on the other thin-bed types. In this article, all of the thin-beds are classified into four types: thin-beds with equal magnitude and opposite polarity, thin-beds with unequal magnitude and opposite polarity, thin-beds with equal magnitude and identical polarity, and thin-beds with unequal magnitude and identical polarity. By analytical study, an equation describing the general relationship between seismic peak frequency and thin-bed thickness was derived which shows there is a Complex implicit non-linear relationship between them and which is difficult to use in practice. In order to solve this problem, we simplify the relationship by Taylor expansion and discuss the precision of the approximation formulae with different orders for the four types of thin-beds. Compared with the traditional amplitude method for thin-bed thickness calculation, the method we present has a higher precision and isn't influenced by the absolute value of top or bottom reflection coefficient, so it is convenient for use in practice.展开更多
Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the proble...Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the problems of complex synchronous sampling method and long locking time after varying sampling rate in traditional underwater seismic exploration system,an improved synchronous sampling model based on the master-slave synchronous model and local clock asynchronous drive with non phase locked loop(PLL)is built,and a high-precision synchronous sampling method is proposed,which combines the short-term stability of local asynchronous driving clock with the master-slave synchronous calibration of local sampling clock.Based on the improved synchronous sampling model,the influence of clock stability,transmission delay and phase jitter on synchronous sampling error is analyzed,and a high-precision calibration method of synchronous sampling error based on step-by-step compensation of transmission delay is proposed.The model and method effectively realize the immunity of phase jitter on synchronous sampling error in principle,and compensate the influence of signal transmission delay on synchronous sampling error.At the same time,it greatly reduces the complexity of software and hardware implementation of synchronous sampling,and solves the problem of long locking time after changing the sampling rate in traditional methods.The experimental system of synchronous sampling for dual linear array is built,and the synchronous sampling accuracy is better than 5 ns.展开更多
基金supported by National Key S&T Special Projects of Marine Carbonate 2008ZX05000-004CNPC Projects 2008E-0610-10
文摘Quantitative thickness estimation below tuning thickness is a great challenge in seismic exploration. Most studies focus on the thin-beds whose top and bottom reflection coefficients are of equal magnitude and opposite polarity. There is no systematic research on the other thin-bed types. In this article, all of the thin-beds are classified into four types: thin-beds with equal magnitude and opposite polarity, thin-beds with unequal magnitude and opposite polarity, thin-beds with equal magnitude and identical polarity, and thin-beds with unequal magnitude and identical polarity. By analytical study, an equation describing the general relationship between seismic peak frequency and thin-bed thickness was derived which shows there is a Complex implicit non-linear relationship between them and which is difficult to use in practice. In order to solve this problem, we simplify the relationship by Taylor expansion and discuss the precision of the approximation formulae with different orders for the four types of thin-beds. Compared with the traditional amplitude method for thin-bed thickness calculation, the method we present has a higher precision and isn't influenced by the absolute value of top or bottom reflection coefficient, so it is convenient for use in practice.
基金National Key Research and Development Program of China(No.2018YFE0208200)National Natural Science Foundation of China(Nos.61971307,61905175,51775377)+5 种基金National Key Research and Development Plan Project(No.2020YFB2010800)The Fok Ying Tung Education Foundation(No.171055)China Postdoctoral Science Foundation(No.2020M680878)Guangdong Province Key Research and Development Plan Project(No.2020B0404030001)Tianjin Science and Technology Plan Project(No.20YDTPJC01660)Project of Foreign Affairs Committee of China Aviation Development Sichuan Gas Turbine Research Institute(Nos.GJCZ-2020-0040,GJCZ-2020-0041)。
文摘Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the problems of complex synchronous sampling method and long locking time after varying sampling rate in traditional underwater seismic exploration system,an improved synchronous sampling model based on the master-slave synchronous model and local clock asynchronous drive with non phase locked loop(PLL)is built,and a high-precision synchronous sampling method is proposed,which combines the short-term stability of local asynchronous driving clock with the master-slave synchronous calibration of local sampling clock.Based on the improved synchronous sampling model,the influence of clock stability,transmission delay and phase jitter on synchronous sampling error is analyzed,and a high-precision calibration method of synchronous sampling error based on step-by-step compensation of transmission delay is proposed.The model and method effectively realize the immunity of phase jitter on synchronous sampling error in principle,and compensate the influence of signal transmission delay on synchronous sampling error.At the same time,it greatly reduces the complexity of software and hardware implementation of synchronous sampling,and solves the problem of long locking time after changing the sampling rate in traditional methods.The experimental system of synchronous sampling for dual linear array is built,and the synchronous sampling accuracy is better than 5 ns.