期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
地源热泵孵化系统中均温装置的优化和试验 被引量:1
1
作者 林俊 张毅 蒙健 《中国农机化学报》 2016年第7期205-209,共5页
针对单台地源热泵孵化系统设备均温装置的能耗占孵化周期的总能耗大,优化设计加热装置(PU管)的位置布局以及均温装置的位置布局,从而实现优化均温装置节能的目的。孵化试验结果表明:优化后的地源热泵孵化周期的均温装置功率占总功率的2.... 针对单台地源热泵孵化系统设备均温装置的能耗占孵化周期的总能耗大,优化设计加热装置(PU管)的位置布局以及均温装置的位置布局,从而实现优化均温装置节能的目的。孵化试验结果表明:优化后的地源热泵孵化周期的均温装置功率占总功率的2.1%,相对于优化前的地源热泵装机功率占总功率的12.5%,节能率达82.9%;其均温效果良好,孵化效果明显且经济效益高。 展开更多
关键词 地源热泵 均温装置 位置布局 节能优化
下载PDF
冰水均温装置在乳品冷却系统中的应用 被引量:2
2
作者 赵金龙 李建臣 《制冷》 2004年第3期59-61,共3页
阐述了冰水均温装置的工作原理、结构组成、性能特点 ,介绍了该装置在乳品超高温杀菌后的冰水冷却系统中应用的显著效果。
关键词 乳品 均温装置 冷却 制冷
下载PDF
Exhaust Ventilation through a Solar Chimney: A Response to High Hermeticity in Welfare Housing
3
作者 Marcos Eduardo Gonzalez-Trevizo Adolfo Gomez-Amador +2 位作者 Anibal Luna-Leon Carlos Escobar-Del POZO Carlos Javier Esparza Lopez 《Journal of Civil Engineering and Architecture》 2015年第7期767-774,共8页
This research reports on potentiality in the solar chimney as an exhaust ventilation device through a hypothetical statement that convenient weather conditions exist on sub-humid warm climate to enhance the performanc... This research reports on potentiality in the solar chimney as an exhaust ventilation device through a hypothetical statement that convenient weather conditions exist on sub-humid warm climate to enhance the performance ofa SC (solar chimney), in order to increase ventilation to dissipate metabolic heat from inhabitants of airtight buildings. The methodology used in this research integrates the use of simplified mathematical models that predict in a semi-empirical way a potential volume flow through estimation of kinetic power generation, by natural circulation and stack effect in a typical covered-plate air solar collector. The study was carried out during the warm month of April, an important warm season for Colima, where the prevailing wind is about 6.8 m/s, the average temperature of maximums and minimums oscillates between 15.4℃and 34.4 ℃ with average relative humidity of 65% according to national weather service. A scale model of the SC was installed on environmental chambers. The results showed that this device is capable of generating ventilation conditions around light breeze parameters near between 0.6 m/s and 1.5 m/s width, a better performance at day in 45% approximately than the night values, making ventilation rates up 0.24 ACH (air changes per hour) as average air change rate. 展开更多
关键词 Exhaust ventilation solar chimney air solar collector welfare housing.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部