A special PLC is designed for the control system of garbage truck,based on the feature and applications of vehicular electrical device.The purpose is developing a kind of mature products to control the hydraulic syste...A special PLC is designed for the control system of garbage truck,based on the feature and applications of vehicular electrical device.The purpose is developing a kind of mature products to control the hydraulic system.The general design plans are described,in detail,and the design points are analyzed and summarized.展开更多
This paper presents findings from an investigation of the large-scale construction solid waste (CSW) landslide that occurred at a landfill at Shenzhen, Guangdong, China, on December 20, 2015, and which killed 77 peo...This paper presents findings from an investigation of the large-scale construction solid waste (CSW) landslide that occurred at a landfill at Shenzhen, Guangdong, China, on December 20, 2015, and which killed 77 people and destroyed 33 houses. The landslide involved 2.73 - 106 m3 of CSW and affected an area about 1100 m in length and 630 m in maximum width, making it the largest landfill landslide in the world. The investigation of this disaster used a combination of unmanned aerial vehicle surveillance and multistage remote-sensing images to reveal the increasing volume of waste in the landfill and the shifting shape of the landfill slope for nearly two years before the landslide took place, beginning with the creation of the CSW landfill in March, 2014, that resulted in the uncertain conditions of the landfill's boundaries and the unstable state of the hydrologic performance. As a result, applying conventional stability analysis methods used for natural landslides to this case would be difficult. In order to analyze this disaster, we took a multistage modeling technique to analyze the varied characteristics of the land- fill slope's structure at various stages of CSW dumping and used the non-steady flow theory to explain the groundwater seepage problem. The investigation showed that the landfill could be divided into two units based on the moisture in the land: (1) a front uint, consisted of the landfill slope, which had low water content; and (2) a rear unit, consisted of fresh waste, which had a high water content. This struc- ture caused two effects-surface-water infiltration and consolidation seepage that triggered the landslide in the landfill. Surface-water infiltration induced a gradual increase in pore water pressure head, or piezometric head, in the front slope because the infiltrating position rose as the volume of waste placement increased. Consolidation seepage led to higher excess pore water pressures as the loading of waste increased. We also investigated the post-failure soil dynamics parameters of the landslide deposit using cone penetration, triaxial, and ring-shear tests in order to simulate the characteristics of a flowing slide with a long run-out due to the liquefaction effect. Finally, we conclude the paper with lessons from the tens of catastrophic landslides of municipal solid waste around the world and discuss how to better manage the geotechnical risks of urbanization.展开更多
Bandung, adopted a policy to build Waste to Energy (WTE) systems with a combustion capacity of 500 tons/day. WTE technologies will burn waste that is fed and utilized energy generated to be converted into electrical...Bandung, adopted a policy to build Waste to Energy (WTE) systems with a combustion capacity of 500 tons/day. WTE technologies will burn waste that is fed and utilized energy generated to be converted into electrical energy. This technology has the potential to reduce the volume of waste more effectively, but WTE also emit various harmful contaminants, including Polychlorinated Dibenzofurans (PCDF) and Polychlorinated Dibenzo-p-Dioxins (PCDDs). WTE equipped with air pollution control, so that the emission of harmful contaminants can be controlled and detected continuously. This study only discusses contaminants PCDF and PCDDs, and the effect of air pollution control work against public health risks. In this study, the efficiency of air pollution control is assumed at 0%, 25%, 50%, 75%, 90% and 99%, while the public health risk assessment carried out for the projected 15 years into the future. Public health risk assessment carried out by the calculation of the health risk of carcinogenic (liver cancer). A causal relationship between the independent variable efficiency of air pollution control with one dependent variable number of liver cancer patients, obtained the simple linear regression equation Y = 76.4592 - 0.7692X.展开更多
文摘A special PLC is designed for the control system of garbage truck,based on the feature and applications of vehicular electrical device.The purpose is developing a kind of mature products to control the hydraulic system.The general design plans are described,in detail,and the design points are analyzed and summarized.
文摘This paper presents findings from an investigation of the large-scale construction solid waste (CSW) landslide that occurred at a landfill at Shenzhen, Guangdong, China, on December 20, 2015, and which killed 77 people and destroyed 33 houses. The landslide involved 2.73 - 106 m3 of CSW and affected an area about 1100 m in length and 630 m in maximum width, making it the largest landfill landslide in the world. The investigation of this disaster used a combination of unmanned aerial vehicle surveillance and multistage remote-sensing images to reveal the increasing volume of waste in the landfill and the shifting shape of the landfill slope for nearly two years before the landslide took place, beginning with the creation of the CSW landfill in March, 2014, that resulted in the uncertain conditions of the landfill's boundaries and the unstable state of the hydrologic performance. As a result, applying conventional stability analysis methods used for natural landslides to this case would be difficult. In order to analyze this disaster, we took a multistage modeling technique to analyze the varied characteristics of the land- fill slope's structure at various stages of CSW dumping and used the non-steady flow theory to explain the groundwater seepage problem. The investigation showed that the landfill could be divided into two units based on the moisture in the land: (1) a front uint, consisted of the landfill slope, which had low water content; and (2) a rear unit, consisted of fresh waste, which had a high water content. This struc- ture caused two effects-surface-water infiltration and consolidation seepage that triggered the landslide in the landfill. Surface-water infiltration induced a gradual increase in pore water pressure head, or piezometric head, in the front slope because the infiltrating position rose as the volume of waste placement increased. Consolidation seepage led to higher excess pore water pressures as the loading of waste increased. We also investigated the post-failure soil dynamics parameters of the landslide deposit using cone penetration, triaxial, and ring-shear tests in order to simulate the characteristics of a flowing slide with a long run-out due to the liquefaction effect. Finally, we conclude the paper with lessons from the tens of catastrophic landslides of municipal solid waste around the world and discuss how to better manage the geotechnical risks of urbanization.
文摘Bandung, adopted a policy to build Waste to Energy (WTE) systems with a combustion capacity of 500 tons/day. WTE technologies will burn waste that is fed and utilized energy generated to be converted into electrical energy. This technology has the potential to reduce the volume of waste more effectively, but WTE also emit various harmful contaminants, including Polychlorinated Dibenzofurans (PCDF) and Polychlorinated Dibenzo-p-Dioxins (PCDDs). WTE equipped with air pollution control, so that the emission of harmful contaminants can be controlled and detected continuously. This study only discusses contaminants PCDF and PCDDs, and the effect of air pollution control work against public health risks. In this study, the efficiency of air pollution control is assumed at 0%, 25%, 50%, 75%, 90% and 99%, while the public health risk assessment carried out for the projected 15 years into the future. Public health risk assessment carried out by the calculation of the health risk of carcinogenic (liver cancer). A causal relationship between the independent variable efficiency of air pollution control with one dependent variable number of liver cancer patients, obtained the simple linear regression equation Y = 76.4592 - 0.7692X.