In order to analyze power system stability in environment of WAMS(wide area measurement system),a new steady state stability model with time-varying delay was proposed for power system.The factors of exciter and power...In order to analyze power system stability in environment of WAMS(wide area measurement system),a new steady state stability model with time-varying delay was proposed for power system.The factors of exciter and power system stabilizer with delay were introduced into analytical model.To decrease conservativeness of stability analysis,an improved Lyapunov-Krasovskii functional was constructed,and then a new delay-dependent steady state stability criterion for power system,which overcomes the disadvantages of eigenvalue computation method,was derived.The proposed model and criterion were tested on synchronous-machine infinite-bus power system.The test results demonstrate that Lyapunov-Krasovskii functional based power system stability analysis method is applicable and effective in the analysis of time delay power system stability.展开更多
By system analysis and imitating modeling authors show the most effective modern techniques for railway electric systems control. Modem measure technologies PMU-WAMS and smart grid allow to solve real time tasks of ce...By system analysis and imitating modeling authors show the most effective modern techniques for railway electric systems control. Modem measure technologies PMU-WAMS and smart grid allow to solve real time tasks of centralizing control of railway electric systems. Quantity characteristics of control effectiveness are determined. According to computer modeling the situation approach is available for practical tasks of railway electric system control.展开更多
A method is proposed to monitor and control Hopf bifurcations in multi-machine power systems using the information from wide area measurement systems (WAMSs). The power method (PM) is adopted to compute the pair of co...A method is proposed to monitor and control Hopf bifurcations in multi-machine power systems using the information from wide area measurement systems (WAMSs). The power method (PM) is adopted to compute the pair of conjugate eigenvalues with the algebraically largest real part and the corresponding eigenvectors of the Jacobian matrix of a power system. The distance between the current equilibrium point and the Hopf bifurcation set can be monitored dynamically by computing the pair of con- jugate eigenvalues. When the current equilibrium point is close to the Hopf bifurcation set, the approximate normal vector to the Hopf bifurcation set is computed and used as a direction to regulate control parameters to avoid a Hopf bifurcation in the power system described by differential algebraic equations (DAEs). The validity of the proposed method is demonstrated by regulating the reactive power loads in a 14-bus power system.展开更多
Fast-flux is a Domain Name System(DNS)technique used by botnets to organise compromised hosts into a high-availability,loadbalancing network that is similar to Content Delivery Networks(CDNs).Fast-Flux Service Network...Fast-flux is a Domain Name System(DNS)technique used by botnets to organise compromised hosts into a high-availability,loadbalancing network that is similar to Content Delivery Networks(CDNs).Fast-Flux Service Networks(FFSNs)are usually used as proxies of phishing websites and malwares,and hide upstream servers that host actual content.In this paper,by analysing recursive DNS traffic,we develop a fast-flux domain detection method which combines both real-time detection and long-term monitoring.Experimental results demonstrate that our solution can achieve significantly higher detection accuracy values than previous flux-score based algorithms,and is light-weight in terms of resource consumption.We evaluate the performance of the proposed fast-flux detection and tracking solution during a 180-day period of deployment on our university’s DNS servers.Based on the tracking results,we successfully identify the changes in the distribution of FFSN and their roles in recent Internet attacks.展开更多
This paper proposes a multi-layer multi-agent model for the performance evaluation of powersystems,which is different from the existing multi-agent ones.To describe the impact of the structureof the networked power sy...This paper proposes a multi-layer multi-agent model for the performance evaluation of powersystems,which is different from the existing multi-agent ones.To describe the impact of the structureof the networked power system,the proposed model consists of three kinds of agents that form threelayers:control agents such as the generators and associated controllers,information agents to exchangethe information based on the wide area measurement system (WAMS) or transmit control signals tothe power system stabilizers (PSSs),and network-node agents such as the generation nodes and loadnodes connected with transmission lines.An optimal index is presented to evaluate the performance ofdamping controllers to the system's inter-area oscillation with respect to the information-layer topology.Then,the authors show that the inter-area information exchange is more powerful than the exchangewithin a given area to control the inter-area low frequency oscillation based on simulation analysis.展开更多
In this paper, a novel method that integrates the improved empirical mode decomposition (EMD) and signal energy algorithm is proposed to estimate the dominant oscillation parameters and corresponding mode shape. Fir...In this paper, a novel method that integrates the improved empirical mode decomposition (EMD) and signal energy algorithm is proposed to estimate the dominant oscillation parameters and corresponding mode shape. Firstly, the EMD with symmetrical extrema extension (SEE) is utilized to decompose the measured data from wide area measurement system (WAMS) into a finite set of intrinsic mode functions (1MFs). Then, the signal energy algorithm is used to calculate the approximate oscillation parameters of the IMFs. The nodes involved the dominant oscillation mode are classified based on the calculated frequency and reasonable threshold. Furthermore, for the dominant oscillation mode, the IMF with maximum mean amplitude is defined as the reference. Next, the relative phases (RPs) between the reference IMF and other 1MFs are calculated in order to identify the negative and positive oscillation groups. According to the values of RPs, the coherent group and corresponding node contribution factor (NCF) can be identified, and the dominant approximate mode shape (AMS) can also be determined. The efficiency of the proposed approach is tested by applying it to synthetic signal and measured data from the simulation model.展开更多
By considering the static voltage characteristic of the load, we propose a WAMS/SCADA mixed nonlinear method to estimate the voltage of unobservable buses caused by topology change or phasor measurement unit (PMU) mal...By considering the static voltage characteristic of the load, we propose a WAMS/SCADA mixed nonlinear method to estimate the voltage of unobservable buses caused by topology change or phasor measurement unit (PMU) malfunction in a power system. By modeling the load characteristic with data from SCADA, we employed the Gauss-Seidel method to solve the nonlinear equations and estimate the voltage of unobservable buses with the high precision voltages of neighboring buses measured by a PMU. Simulations were carried out on the IEEE 39-bus system, and the results show that this novel method can dynamically and accurately trace the variation of the voltage phasor of the unobservable buses.展开更多
Using 12 years of data from the Tropical Rainfall Measuring Mission(TRMM)-based Precipitation Radar(PR),spatial and diurnal variations of deep convective systems(DCSs)over the Asian monsoon region are analyzed.The DCS...Using 12 years of data from the Tropical Rainfall Measuring Mission(TRMM)-based Precipitation Radar(PR),spatial and diurnal variations of deep convective systems(DCSs)over the Asian monsoon region are analyzed.The DCSs are defined by a 20 dBZ echo top extending 14 km.The spatial distribution of DCSs genesis is also discussed,with reference to the National Centers for Environmental Prediction(NCEP)reanalysis data.The results show that DCSs occur mainly over land.They concentrate in south of 20°N during the pre-monsoon season,and then move distinctly to mid-latitude regions,with the most active region on the south slope of the Himalayas during monsoon season.DCSs over the Tibetan Plateau are more frequent than those in central-eastern China,but smaller in horizontal scale and weaker in convective intensity.DCSs in central-eastern China have more robust updrafts and generate more lightning flashes than in other Asian monsoon regions.The horizontal scale of DCSs over the ocean is larger than that over the other regions,and the corresponding minimum infrared(IR)brightness temperature is lower,whereas the convective intensity is weaker.Continental DCSs are more common from noon through midnight,and DCSs over the Tibetan Plateau are more frequently from noon through evening.Oceanic DCSs frequency has a weaker diurnal cycle with dawn maximum,and diurnal variation of DCSs over the tropical maritime continent is consistent with that over the continent.展开更多
Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The prin...Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The principle of the proposed technique to reduce the fading noise is introduced based on the analysis of Rayleigh Brillouin optical time domain analysis system. The experimental results show that the signal-to-noise ratio(SNR) at the end of optical fiber with length of 50 m after 17 times wavelength scanning is 5.21 d B higher than that with single wavelength, the Brillouin frequency shift(BFS) on the heated fiber with length of 70 m inserted at the center of sensing fiber can be accurately measured as 0.19 MHz, which is equivalent to a measurement accuracy of 0.19 °C. It indicates that the proposed technique can realize high-accuracy temperature measurement and has huge potential in the field of long-distance and high-accuracy sensing.展开更多
基金Projects(60425310,60974026) supported by the National Natural Science Foundation of ChinaProject(200805330004) supported by the Doctor Subject Foundation of China+1 种基金Projects(NCET-06-0679) supported by Program for New Century Excellent Talents in UniversityProject(08JJ1010) supported by the Natural Science Foundation of Hunan Province,China
文摘In order to analyze power system stability in environment of WAMS(wide area measurement system),a new steady state stability model with time-varying delay was proposed for power system.The factors of exciter and power system stabilizer with delay were introduced into analytical model.To decrease conservativeness of stability analysis,an improved Lyapunov-Krasovskii functional was constructed,and then a new delay-dependent steady state stability criterion for power system,which overcomes the disadvantages of eigenvalue computation method,was derived.The proposed model and criterion were tested on synchronous-machine infinite-bus power system.The test results demonstrate that Lyapunov-Krasovskii functional based power system stability analysis method is applicable and effective in the analysis of time delay power system stability.
文摘By system analysis and imitating modeling authors show the most effective modern techniques for railway electric systems control. Modem measure technologies PMU-WAMS and smart grid allow to solve real time tasks of centralizing control of railway electric systems. Quantity characteristics of control effectiveness are determined. According to computer modeling the situation approach is available for practical tasks of railway electric system control.
基金the National Natural Science Foundation of China (Nos. 50595414 and 50507018)the National Key Technolo-gies Supporting Program of China during the 11th Five-Year Plan Period (No. 2006BAA02A01)the Key Grant Project of MOE, China (No. 305008)
文摘A method is proposed to monitor and control Hopf bifurcations in multi-machine power systems using the information from wide area measurement systems (WAMSs). The power method (PM) is adopted to compute the pair of conjugate eigenvalues with the algebraically largest real part and the corresponding eigenvectors of the Jacobian matrix of a power system. The distance between the current equilibrium point and the Hopf bifurcation set can be monitored dynamically by computing the pair of con- jugate eigenvalues. When the current equilibrium point is close to the Hopf bifurcation set, the approximate normal vector to the Hopf bifurcation set is computed and used as a direction to regulate control parameters to avoid a Hopf bifurcation in the power system described by differential algebraic equations (DAEs). The validity of the proposed method is demonstrated by regulating the reactive power loads in a 14-bus power system.
基金supported by the National Basic Research Program of China(973 Program)under Grant No.2013CB329603Huawei Innovation Research Program+1 种基金the Opening Project of Key Laboratory of Information Network Security of Ministry of Public Security under Grant No.C11608the National Natural Science Foundation of China under Grant No.61271220
文摘Fast-flux is a Domain Name System(DNS)technique used by botnets to organise compromised hosts into a high-availability,loadbalancing network that is similar to Content Delivery Networks(CDNs).Fast-Flux Service Networks(FFSNs)are usually used as proxies of phishing websites and malwares,and hide upstream servers that host actual content.In this paper,by analysing recursive DNS traffic,we develop a fast-flux domain detection method which combines both real-time detection and long-term monitoring.Experimental results demonstrate that our solution can achieve significantly higher detection accuracy values than previous flux-score based algorithms,and is light-weight in terms of resource consumption.We evaluate the performance of the proposed fast-flux detection and tracking solution during a 180-day period of deployment on our university’s DNS servers.Based on the tracking results,we successfully identify the changes in the distribution of FFSN and their roles in recent Internet attacks.
基金supported in part by the National Natural Science Foundation of China under Grants Nos. 50707035, 50595411, 60425307, 60221301 and 50607005, in part by the 111 project (B08013)Program for Changjiang Scholars and Innovative Research Team in University (IRT0515)in part by the Program for New Century Excellent Talents in University (NCET-05-0216)
文摘This paper proposes a multi-layer multi-agent model for the performance evaluation of powersystems,which is different from the existing multi-agent ones.To describe the impact of the structureof the networked power system,the proposed model consists of three kinds of agents that form threelayers:control agents such as the generators and associated controllers,information agents to exchangethe information based on the wide area measurement system (WAMS) or transmit control signals tothe power system stabilizers (PSSs),and network-node agents such as the generation nodes and loadnodes connected with transmission lines.An optimal index is presented to evaluate the performance ofdamping controllers to the system's inter-area oscillation with respect to the information-layer topology.Then,the authors show that the inter-area information exchange is more powerful than the exchangewithin a given area to control the inter-area low frequency oscillation based on simulation analysis.
文摘In this paper, a novel method that integrates the improved empirical mode decomposition (EMD) and signal energy algorithm is proposed to estimate the dominant oscillation parameters and corresponding mode shape. Firstly, the EMD with symmetrical extrema extension (SEE) is utilized to decompose the measured data from wide area measurement system (WAMS) into a finite set of intrinsic mode functions (1MFs). Then, the signal energy algorithm is used to calculate the approximate oscillation parameters of the IMFs. The nodes involved the dominant oscillation mode are classified based on the calculated frequency and reasonable threshold. Furthermore, for the dominant oscillation mode, the IMF with maximum mean amplitude is defined as the reference. Next, the relative phases (RPs) between the reference IMF and other 1MFs are calculated in order to identify the negative and positive oscillation groups. According to the values of RPs, the coherent group and corresponding node contribution factor (NCF) can be identified, and the dominant approximate mode shape (AMS) can also be determined. The efficiency of the proposed approach is tested by applying it to synthetic signal and measured data from the simulation model.
基金Project supported by the National Natural Science Foundation of China (Nos. 50507018, 50595414, 50677062, and 60421002)the National Basic Research Program (973) of China (No. 2004CB217902)+1 种基金the National Key Technologies Supporting Program of Chinaduring the 11th Five-Year Plan Period (No. 2006BAA02A01)theKey Grant Project of MOE of China (No. 305008)
文摘By considering the static voltage characteristic of the load, we propose a WAMS/SCADA mixed nonlinear method to estimate the voltage of unobservable buses caused by topology change or phasor measurement unit (PMU) malfunction in a power system. By modeling the load characteristic with data from SCADA, we employed the Gauss-Seidel method to solve the nonlinear equations and estimate the voltage of unobservable buses with the high precision voltages of neighboring buses measured by a PMU. Simulations were carried out on the IEEE 39-bus system, and the results show that this novel method can dynamically and accurately trace the variation of the voltage phasor of the unobservable buses.
基金supported jointly by the National Basic Research Program of China(Grant No.2010CB428601)the National Natural Science Foundation of China(Grant Nos. 40930949&40905008)
文摘Using 12 years of data from the Tropical Rainfall Measuring Mission(TRMM)-based Precipitation Radar(PR),spatial and diurnal variations of deep convective systems(DCSs)over the Asian monsoon region are analyzed.The DCSs are defined by a 20 dBZ echo top extending 14 km.The spatial distribution of DCSs genesis is also discussed,with reference to the National Centers for Environmental Prediction(NCEP)reanalysis data.The results show that DCSs occur mainly over land.They concentrate in south of 20°N during the pre-monsoon season,and then move distinctly to mid-latitude regions,with the most active region on the south slope of the Himalayas during monsoon season.DCSs over the Tibetan Plateau are more frequent than those in central-eastern China,but smaller in horizontal scale and weaker in convective intensity.DCSs in central-eastern China have more robust updrafts and generate more lightning flashes than in other Asian monsoon regions.The horizontal scale of DCSs over the ocean is larger than that over the other regions,and the corresponding minimum infrared(IR)brightness temperature is lower,whereas the convective intensity is weaker.Continental DCSs are more common from noon through midnight,and DCSs over the Tibetan Plateau are more frequently from noon through evening.Oceanic DCSs frequency has a weaker diurnal cycle with dawn maximum,and diurnal variation of DCSs over the tropical maritime continent is consistent with that over the continent.
基金supported by the National Natural Science Foundation of China(No.61377088)the Natural Science Foundation of Hebei Province of China(Nos.E2015502053 and F2015502059)the Fundamental Research Funds for the Central Universities(No.2016XS104)
文摘Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The principle of the proposed technique to reduce the fading noise is introduced based on the analysis of Rayleigh Brillouin optical time domain analysis system. The experimental results show that the signal-to-noise ratio(SNR) at the end of optical fiber with length of 50 m after 17 times wavelength scanning is 5.21 d B higher than that with single wavelength, the Brillouin frequency shift(BFS) on the heated fiber with length of 70 m inserted at the center of sensing fiber can be accurately measured as 0.19 MHz, which is equivalent to a measurement accuracy of 0.19 °C. It indicates that the proposed technique can realize high-accuracy temperature measurement and has huge potential in the field of long-distance and high-accuracy sensing.