Accurate estimation of liquid thermal conductivity is highly necessary to appropriately design equipments in different industries. Respect to this necessity, in the current investigation a feed-forward artificial neur...Accurate estimation of liquid thermal conductivity is highly necessary to appropriately design equipments in different industries. Respect to this necessity, in the current investigation a feed-forward artificial neural network(ANN) model is examined to correlate the liquid thermal conductivity of normal and aromatic hydrocarbons at the temperatures range of 257–338 K and atmospheric pressure. For this purpose, 956 experimental thermal conductivities for normal and aromatic hydrocarbons are collected from different previously published literature.During the modeling stage, to discriminate different substances, critical temperature(Tc), critical pressure(Pc)and acentric factor(ω) are utilized as the network inputs besides the temperature. During the examination, effects of different transfer functions and number of neurons in hidden layer are investigated to find the optimum network architecture. Besides, statistical error analysis considering the results obtained from available correlations and group contribution methods and proposed neural network is performed to reliably check the feasibility and accuracy of the proposed method. Respect to the obtained results, it can be concluded that the proposed neural network consisted of three layers namely, input, hidden and output layers with 22 neurons in hidden layer was the optimum ANN model. Generally, the proposed model enables to correlate the thermal conductivity of normal and aromatic hydrocarbons with absolute average relative deviation percent(AARD), mean square error(MSE), and correlation coefficient(R^2) of lower than 0.2%, 1.05 × 10^(-7) and 0.9994, respectively.展开更多
In order to study the theoretical cycle characteristic of [mmim]DMP (1-methyl-3-methylimidazolium dimethyl- phosphate)/methanol absorption refrigeration, the modified UNIFAC group contribution model and the Wilson m...In order to study the theoretical cycle characteristic of [mmim]DMP (1-methyl-3-methylimidazolium dimethyl- phosphate)/methanol absorption refrigeration, the modified UNIFAC group contribution model and the Wilson model are established through correlating the experimental vapor pressure data of [mmim]DMP/methanol at T= 280~370 K and methanol mole fraction x= 0.529-0.965. Thermodynamic performances of absorption refrigera- tion utilizing [mmim]DMP/methanol, LiBr/H20 and H20/NH3 are investigated and compared with each other under the same operating conditions. From the results, some conclusions are obtained as follows: 1) the circula- tion ratio of the [mmim]DMP/methanol absorption refrigeration is higher than that of the LiBr/H2O absorption refrigeration, but still can be acceptable and tolerable. 2) The COP of the [mmim]DMP/methanol absorption refrigeration is smaller than that of the LiBr/H2O absorption refrigeration, while it is higher than that of the H2O/NH3 absorption refrigeration under most operating conditions. 3) The [mmim]DMP/methanol absorption refrigeration are still available with high COP when the heat source temperature is too high to drive LiBr/H2O absorption refrigeration.展开更多
文摘Accurate estimation of liquid thermal conductivity is highly necessary to appropriately design equipments in different industries. Respect to this necessity, in the current investigation a feed-forward artificial neural network(ANN) model is examined to correlate the liquid thermal conductivity of normal and aromatic hydrocarbons at the temperatures range of 257–338 K and atmospheric pressure. For this purpose, 956 experimental thermal conductivities for normal and aromatic hydrocarbons are collected from different previously published literature.During the modeling stage, to discriminate different substances, critical temperature(Tc), critical pressure(Pc)and acentric factor(ω) are utilized as the network inputs besides the temperature. During the examination, effects of different transfer functions and number of neurons in hidden layer are investigated to find the optimum network architecture. Besides, statistical error analysis considering the results obtained from available correlations and group contribution methods and proposed neural network is performed to reliably check the feasibility and accuracy of the proposed method. Respect to the obtained results, it can be concluded that the proposed neural network consisted of three layers namely, input, hidden and output layers with 22 neurons in hidden layer was the optimum ANN model. Generally, the proposed model enables to correlate the thermal conductivity of normal and aromatic hydrocarbons with absolute average relative deviation percent(AARD), mean square error(MSE), and correlation coefficient(R^2) of lower than 0.2%, 1.05 × 10^(-7) and 0.9994, respectively.
基金supported by the National Basic Research Program of China (973 Program) under Grant No.2012CB933200the National Natural Science Fundation of China under Grant No.51276180
文摘In order to study the theoretical cycle characteristic of [mmim]DMP (1-methyl-3-methylimidazolium dimethyl- phosphate)/methanol absorption refrigeration, the modified UNIFAC group contribution model and the Wilson model are established through correlating the experimental vapor pressure data of [mmim]DMP/methanol at T= 280~370 K and methanol mole fraction x= 0.529-0.965. Thermodynamic performances of absorption refrigera- tion utilizing [mmim]DMP/methanol, LiBr/H20 and H20/NH3 are investigated and compared with each other under the same operating conditions. From the results, some conclusions are obtained as follows: 1) the circula- tion ratio of the [mmim]DMP/methanol absorption refrigeration is higher than that of the LiBr/H2O absorption refrigeration, but still can be acceptable and tolerable. 2) The COP of the [mmim]DMP/methanol absorption refrigeration is smaller than that of the LiBr/H2O absorption refrigeration, while it is higher than that of the H2O/NH3 absorption refrigeration under most operating conditions. 3) The [mmim]DMP/methanol absorption refrigeration are still available with high COP when the heat source temperature is too high to drive LiBr/H2O absorption refrigeration.