Based on the compression mechanism for analyzing the cavity expansion problem in soil under high stresses,generalized non-linear failure criterion and large strain and energy conservation in plastic region during the ...Based on the compression mechanism for analyzing the cavity expansion problem in soil under high stresses,generalized non-linear failure criterion and large strain and energy conservation in plastic region during the cavity expanding were adopted.The energy conservation equation was established and the limited pressure of cavity expansion under high stresses was given based on the energy dissipation analysis method,in which the energy generated from cavity expansion is absorbed by the volume change and shear strain caused in soil.The factors of large strain and dilatation were considered by the proposed method.The analysis shows that the limited pressure is determined by failure criterion,stress state,large deformation characteristic,dilatation and strength of soil.It is shown from the comparison that the results with the proposed method approximate to those of the in-situ method.The cavity expansion pressure first decreases and then increases nonlinearly with both of shear modulus and dilatation increasing.展开更多
There are actually several solutions for two axis solar tracking systems using electromechanical devices, in which a controller detects the Sun apparent position, and controls the position of the structure supporting ...There are actually several solutions for two axis solar tracking systems using electromechanical devices, in which a controller detects the Sun apparent position, and controls the position of the structure supporting the panels toward the sun by enabling the engines movement. This work studies the solution of two axis solar tracking system based on solar maps, which can predict the exact apparent position of the Sun, by the latitude's location, thereby avoiding the need to use sensors or guidance systems. To accomplish this, it is used a low-power microcontroller, suitably programmed, to control two electric motors to ensure that the panels supporting structure is always oriented towards the sun.展开更多
This paper presents a nonlinear approach to estimate the consumed energy in electric power distribution feeders. The proposed method uses the statistical solution algorithm to analyze the active energy monthly consump...This paper presents a nonlinear approach to estimate the consumed energy in electric power distribution feeders. The proposed method uses the statistical solution algorithm to analyze the active energy monthly consumption, which enables one to estimate the energy consumption during any period of the year. The energy readings and the normalized accumulated energy profile are used to estimate the hourly consumed active power, which can be used for future planning and sizing the equipment of the electrical system. The effectiveness of the proposed method is demonstrated by comparing the simulated results with that of real measured data.展开更多
Analogizing with the definition of thermal efficiency of a heat exchanger,the entransy dissipation efficiency of a heat exchanger is defined as the ratio of dimensionless entransy dissipation rate to dimensionless pum...Analogizing with the definition of thermal efficiency of a heat exchanger,the entransy dissipation efficiency of a heat exchanger is defined as the ratio of dimensionless entransy dissipation rate to dimensionless pumping power of the heat exchanger.For the constraints of the total tube volume and total tube surface area of the heat exchanger,the constructal optimization of an H-shaped multi-scale heat exchanger is carried out by taking entransy dissipation efficiency maximization as optimization objective,and the optimal construct of the H-shaped multi-scale heat exchanger with maximum entransy dissipation efficiency is obtained.The results show that for the specified total tube volume of the heat exchanger,the optimal constructs of the first order T-shaped heat exchanger based on the maximizations of the thermal efficiency and entransy dissipation efficiency are obviously different with the lower mass flow rates of the cold and hot fluids.For the H-shaped multi-scale heat exchanger,the entransy dissipation efficiency decreases with the increase in mass flow rate when the heat exchanger order is fixed;for the specified dimensionless mass flow rate M(M<32.9),the entransy dissipation efficiency decreases with the increase in the heat exchanger order.The performance of the multi-scale heat exchanger is obviously improved compared with that of the single-scale heat exchanger.Moreover,the heat exchanger subjected to the total tube surface area constraint is also discussed in the paper.The optimization results obtained in this paper can provide a great compromise between the heat transfer and flow performances of the heat exchanger,provide some guidelines for the optimal designs of heat exchangers,and also enrich the connotation of entransy theory.展开更多
基金Projects(2010RS4016,10JJ60708) supported by Hunan Provincial Science Foundation,ChinaProjects(201018,201108,201121) supported by Hunan Provincial Transportation Science and Technology Progress and Innovation Plan of China
文摘Based on the compression mechanism for analyzing the cavity expansion problem in soil under high stresses,generalized non-linear failure criterion and large strain and energy conservation in plastic region during the cavity expanding were adopted.The energy conservation equation was established and the limited pressure of cavity expansion under high stresses was given based on the energy dissipation analysis method,in which the energy generated from cavity expansion is absorbed by the volume change and shear strain caused in soil.The factors of large strain and dilatation were considered by the proposed method.The analysis shows that the limited pressure is determined by failure criterion,stress state,large deformation characteristic,dilatation and strength of soil.It is shown from the comparison that the results with the proposed method approximate to those of the in-situ method.The cavity expansion pressure first decreases and then increases nonlinearly with both of shear modulus and dilatation increasing.
文摘There are actually several solutions for two axis solar tracking systems using electromechanical devices, in which a controller detects the Sun apparent position, and controls the position of the structure supporting the panels toward the sun by enabling the engines movement. This work studies the solution of two axis solar tracking system based on solar maps, which can predict the exact apparent position of the Sun, by the latitude's location, thereby avoiding the need to use sensors or guidance systems. To accomplish this, it is used a low-power microcontroller, suitably programmed, to control two electric motors to ensure that the panels supporting structure is always oriented towards the sun.
文摘This paper presents a nonlinear approach to estimate the consumed energy in electric power distribution feeders. The proposed method uses the statistical solution algorithm to analyze the active energy monthly consumption, which enables one to estimate the energy consumption during any period of the year. The energy readings and the normalized accumulated energy profile are used to estimate the hourly consumed active power, which can be used for future planning and sizing the equipment of the electrical system. The effectiveness of the proposed method is demonstrated by comparing the simulated results with that of real measured data.
基金supported by the National Natural Science Foundation of China (Grant No. 51176203)the Natural Science Foundation for Youngsters of Naval University of Engineering (Grant No. HGDQNJJ11008)
文摘Analogizing with the definition of thermal efficiency of a heat exchanger,the entransy dissipation efficiency of a heat exchanger is defined as the ratio of dimensionless entransy dissipation rate to dimensionless pumping power of the heat exchanger.For the constraints of the total tube volume and total tube surface area of the heat exchanger,the constructal optimization of an H-shaped multi-scale heat exchanger is carried out by taking entransy dissipation efficiency maximization as optimization objective,and the optimal construct of the H-shaped multi-scale heat exchanger with maximum entransy dissipation efficiency is obtained.The results show that for the specified total tube volume of the heat exchanger,the optimal constructs of the first order T-shaped heat exchanger based on the maximizations of the thermal efficiency and entransy dissipation efficiency are obviously different with the lower mass flow rates of the cold and hot fluids.For the H-shaped multi-scale heat exchanger,the entransy dissipation efficiency decreases with the increase in mass flow rate when the heat exchanger order is fixed;for the specified dimensionless mass flow rate M(M<32.9),the entransy dissipation efficiency decreases with the increase in the heat exchanger order.The performance of the multi-scale heat exchanger is obviously improved compared with that of the single-scale heat exchanger.Moreover,the heat exchanger subjected to the total tube surface area constraint is also discussed in the paper.The optimization results obtained in this paper can provide a great compromise between the heat transfer and flow performances of the heat exchanger,provide some guidelines for the optimal designs of heat exchangers,and also enrich the connotation of entransy theory.