In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding ca...In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding catenary element considering the out-of-plane stiffness coefficient are put forward.A two-span and a three-span cable structures are taken as examples to verify the sliding cable elements.By comparing the tensions of the two proposed cable elements with the existing research results,the error is less than 1%,which proves the correctness of the proposed elements.The sliding characteristics should be considered in the practical engineering because of the significant difference between the tensions of sliding cable elements and those of cable element without considering sliding.The out-of-plane stiffness coefficient and friction characteristics do not obviously affect the cable tensions.展开更多
High-throughput quantification with label-free methods has received considerable attention in electrospray ionization(ESI)-mass spectrometry(MS),but the manner by which MS signals respond to peptide concentration rema...High-throughput quantification with label-free methods has received considerable attention in electrospray ionization(ESI)-mass spectrometry(MS),but the manner by which MS signals respond to peptide concentration remains unclear in proteomics.We developed a new mathematical formula to describe the intrinsic log-log relationship between the MS intensity response and peptide concentration in an analytical ESI process.Experimental results showed that the calibration curve is fairly fit to the log-log formula with a linear dynamic range of approximate four to five orders of magnitude.However,we found that the ionization of analytical peptides can be severely suppressed by coexisting matrix peptides,such that the calibration curve can be poorly leveled off on both ends.Our study suggests that the interferences from coexisting matrix peptides should be reduced in the ESI process to use the log-log calibration curve successfully for the high-throughput quantification.展开更多
基金Project(51308193)supported by the National Natural Science Foundation of ChinaProject(SGKJ[2007]116)supported by the Science and Technology Program of State Grid Corporation of China
文摘In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding catenary element considering the out-of-plane stiffness coefficient are put forward.A two-span and a three-span cable structures are taken as examples to verify the sliding cable elements.By comparing the tensions of the two proposed cable elements with the existing research results,the error is less than 1%,which proves the correctness of the proposed elements.The sliding characteristics should be considered in the practical engineering because of the significant difference between the tensions of sliding cable elements and those of cable element without considering sliding.The out-of-plane stiffness coefficient and friction characteristics do not obviously affect the cable tensions.
基金supported by the National Basic Research Program of China(2010CB912700,2013CB911201,2011CB910600)the National High Technology Research and Development Program of China(2012AA020203,2014AAQ00361)the National Natural Science Foundation of China(21227805)
文摘High-throughput quantification with label-free methods has received considerable attention in electrospray ionization(ESI)-mass spectrometry(MS),but the manner by which MS signals respond to peptide concentration remains unclear in proteomics.We developed a new mathematical formula to describe the intrinsic log-log relationship between the MS intensity response and peptide concentration in an analytical ESI process.Experimental results showed that the calibration curve is fairly fit to the log-log formula with a linear dynamic range of approximate four to five orders of magnitude.However,we found that the ionization of analytical peptides can be severely suppressed by coexisting matrix peptides,such that the calibration curve can be poorly leveled off on both ends.Our study suggests that the interferences from coexisting matrix peptides should be reduced in the ESI process to use the log-log calibration curve successfully for the high-throughput quantification.