Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld...Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld was welded to a stainless steel pipe with laser spot welding process.The microstructure of the welds was examined with an optical microscope and the elemental distribution in the welds was measured by electron probe microanalysis(EPMA).The results show that TiC compounds dispersively distribute in the NiTi SMA TIG weld.However,the amount of TiC compounds greatly decreases around the fusion boundary of the laser spot weld between the NiTi SMA and stainless steel.Mutual diffusion between NiTi shape memory alloy and stainless steel happen within a short distance near the fusion boundary,and intermetallic compounds such as Ni3Ti+(Fe,Ni)Ti appear around the fusion boundary.展开更多
Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age...Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age) were selected for percutaneous closure of ASD bytrans-esophageal echocardiography, which was also used to monitor the procedure, to select theappropriate size of the Amplatzer device, to verify its position, and to access the immediateresults of the procedure. During the follow-up, transthoracic echocardiography (TTE) or TEE was usedto evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiacchamber diameters. Results: The mean ASD diameter by TTE ([19. 1 +- 5. 8] mm) was significantlysmaller (P< 0. 001) than the stretched diameter of the ASD (25. 1 +- 6. 4) mm. There are nosignificant differences between the TEE -measured value (23. 5+_6. 2) mm and the stretched diameterof the ASD (P > 0. 05). Due to proper patient selection all procedures were successful. There wasimmediate and complete closure in 61/62 patients, only one patients had trivial residual shunt.Follow- up was performed using TTE or TEE right after operation, 1 d, 1 month, 3 months, 6 monthsand yearly thereafter. Ail, patients remain asymptomatic without any clinical or technical problems.Conclusion: With the aid of TEE, percutaneous closure of ASD can be performed successfully, safely,and effectively.展开更多
Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patient...Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patients with PDA (n = 25) and ASD ( n = 16), confirmed byechocardiography, were treated by transcatheterization. Amplatzer occluder device was placed by thetranscatheterization with the image support of X-ray and transthoracic echocardiography ( TTE) . TheTTE, ECG and X-ray examination were engaged to evaluate the therapeutic results on the time pointsof 24 h , 1, 3 , 6, 12 months after the operation, and all these cases were engaged to the follow-upexamination. Results: The cardioangiographic diameter was 13.0-28.0 mm ([19.3+-4.9] mm) in ASD and2.0-7.7 mm ([3.9+-1.5] mm) in PDA . The diameter of the Amplatzer occluder selected were 13.0-30.0mm ( [20.6+-5.1] mm) in ASD and 4.0-12.0 mm ([6.6+-1.9] mm) in PDA , respectively. All the Amplatzeroccluders were placed successfully. There were no complications during and after the operation.Very small residual shunt was still found soon after the operation in 10 cases , and there were noresidual or recanalization after three months of the operation. The pulmonary artery pressure andheart size were significantly decreased in follow-up examination . Conclusion: Transcatheteringclosure with Amplatzer device is an effective, simple and safe technique in the treatment of ASD andPDA in children.展开更多
Background Coronary artery fistula (CAF) is a rare anomaly.Transcatheter CAF closure has been introduced using various materials,but only few data are available on the Guglielmi detachable coil (GDC).The advantage...Background Coronary artery fistula (CAF) is a rare anomaly.Transcatheter CAF closure has been introduced using various materials,but only few data are available on the Guglielmi detachable coil (GDC).The advantage of using GDC for transcatheter CAF closure is more controllable,therefore much safer when compared to other coils.This report is about our experience in transcatheter closure of CAF using fibered GDC in our hospital.Methods & Results From 2002 to 2007,there were 10 patients with CAFs (age range:28 to 56 year-old,7 males) who underwent transcatheter CAF closure.There were a total of 19 CAFs which originated from right coronary (n =5),left circumflex (n =3),left anterior descending artery (n =10) and left main trunk (n =1).Median number of coil deployment for each fistula was 3 (range:1 to 6).The pulmonary artery was the most common site of the distal communication of CAFs (n =14),followed by right atrium (n =3),left atrium (n =1) and left ventricle (n =1).Immediate coronary angiography after GDC deployment revealed no residual shunt in 12 (63.2%) CAFs,significant reduction of the flow in 5 (26.3%),while 2 (10.5%) could not be closed due to small size.Nine (90%) patients underwent a repeated angiography within 3 to 8 months.Among 12 CAFs that were occluded immediately post-deployment,there were 2 CAFs with insignificant residual flow.Among 6 CAFs with significantly decreased flow immediately post-deployment,2 were occluded totally in the follow-up angiography.In total,12 (70.5%) CAFs were occluded completely and 5 (29.5%) CAFs still had insignificant residual flow,which did not need any additional coil deployment.During a mean follow up of 4.3 ± 0.7 year,all patients remained symptom and complication free.Conclusions The fibered GDC is a safe and effective method for percutaneous closure of the CAFs.展开更多
A 54-year-old female patient with congenital heart disease had a persistent complete left bundle branch block three months after closure by an Amplatzer ventricular septal defect occluder. Nine months later, the patie...A 54-year-old female patient with congenital heart disease had a persistent complete left bundle branch block three months after closure by an Amplatzer ventricular septal defect occluder. Nine months later, the patient suffered from chest distress, palpitation, and sweating at daily activities, and her 6-min walk distance decreased significantly (155 m). Her echocardiography showed increased left ventricular end-diastolic diameter with left ventricular ejection fraction of 37%. Her symptoms reduced significantly one week after received cardiac resynchronization therapy. She had no symptoms at daily activities, and her echo showed left ventricular ejection fraction of 46%and 53%. Moreover, left ventricular end-diastolic diameter decreased 6 and 10 months after cardiac resynchronization therapy, and 6-min walk dis-tance remarkably increased. This case demonstrated that persistent complete left bundle branch block for nine months after transcatheter closure with ventricular septal defect Amplatzer occluder could lead to left ventricular enlargement and a significant decrease in left ventricular systolic function. Cardiac resynchronization therapy decreased left ventricular end-diastolic diameter and increased left ventricular ejection fraction, thereby improving the patient’s heart functions.展开更多
Repeat surgery has usually been considered the first choice to solve paravalvular leaks of prosthetic valves, but it cames a high operative risk, a high mortality rate and an increased risk for re-leaks. Percutaneous ...Repeat surgery has usually been considered the first choice to solve paravalvular leaks of prosthetic valves, but it cames a high operative risk, a high mortality rate and an increased risk for re-leaks. Percutaneous closure of such defects is possible, and different approaches and devices are used for this purpose. For mitral paravalvular leaks, constructing an arterio-venous wire loop for delivering the closure device through an antegrade approach is the most commonly used technique. Transcatheter closure can also be performed through a transapical approach or retrograde transfemoral arterial approach. We present a case of 68-year-old man with a mitral paravalvular leak that was suc- cessfully closed using an Amplatzer~ Duct Occluder H, via retrograde transfemoral arterial approach under three-dimensional transesophag- eal echocardiographic guidance, without the use of a wire loop. The initial attempt to cross the paravalvular defect was unsuccessful, but the obstacle was finally overcome by introducing complex interventional techniques.展开更多
We report the management of a patient with secundum atrial septal defect (ASD) and severe pulmonary hypertension. A 65-year-old male with recently diagnosed atrial septal defect was referred to our centre for decomp...We report the management of a patient with secundum atrial septal defect (ASD) and severe pulmonary hypertension. A 65-year-old male with recently diagnosed atrial septal defect was referred to our centre for decompensated right heart failure with rest and exercise induced dispnea and severe pulmonary hypertension. Right heart catheterization confirmed a mean pulmonary pressure of about 55 mmHg and a Qp/Qs of 2.7. An occlusion test with a compliant large balloon demonstrated partial fall of pulmonary arterial pressure. The implantation of a home-made fenestrated Amplatzer ASD Occluder (ASO) was planned in order to decrease left-to-right shunt and promote further decrease of pulmonary arterial pressure in the long-term. Thus, by means of mechanical intracardiac echocardiography study with a 9F 9 MHz Ultralce catheter (Boston Scientific Corp.), we selected a 34 mm ASO for implantation. Four millimeter fenestration was made inflating a 4 mm non-compliant coronary balloon throughout the waist of the ASO, which was successfully implanted under intmcardiac echocardiography. After six months, a decrease of pulmonary arterial pressure to 24 mmHg and full compensated right heart failure was observed on transthoracic echocardiography and clinical examination. This case suggests that Wanscatheter closure with home-made fenestrated ASD in elderly patients with severe pulmonary hypertension is feasible.展开更多
Aortopuhnonary window is a rare congenital cardiac malformation, which is previously repaired using cardiopulmonary bypass. However, some cases were reported to repair the aortopulmonary septal defect by transcathetcr...Aortopuhnonary window is a rare congenital cardiac malformation, which is previously repaired using cardiopulmonary bypass. However, some cases were reported to repair the aortopulmonary septal defect by transcathetcr closure. Here we present a 30 year-old woman with a 7-mm aortopulmonary window, who was successfully treated using a modified double-disk PmVSD occluder展开更多
Platypnea orthodeoxia syndrome is associated with dyspnea and arterial oxygen desamration accentuated by an upright posture. It can be secondary to an intracardiac shunt. We report a case of platypnea-orthodeoxia synd...Platypnea orthodeoxia syndrome is associated with dyspnea and arterial oxygen desamration accentuated by an upright posture. It can be secondary to an intracardiac shunt. We report a case of platypnea-orthodeoxia syndrome (POS) in a 58-year old male patient who had a pre-existing patent foramen ovale (PFO) and substantial pulmonary pathologies. He was successfully treated by percutaneous transcatheter closure of the PFO. Our case highlights the importance of recognition of this rare syndrome in patients who present with unexplained hy- poxia for whom transcatheter closure of the interatrial shunt can be safely carded out.展开更多
Hemolytic anemia after implantation of an artificial mitral valve is a rare but recognized complication of surgery. The presence of paravalvular leak after surgery and the necessity of using oral anticoagulants causes...Hemolytic anemia after implantation of an artificial mitral valve is a rare but recognized complication of surgery. The presence of paravalvular leak after surgery and the necessity of using oral anticoagulants causes that anemia emerges as a severe and potentially fatal issue.展开更多
In order to present a new method for plugging channeling in oil field,the injection modes and validity period of foam system which plugged the formation water layer were studied by means of the experimental model whic...In order to present a new method for plugging channeling in oil field,the injection modes and validity period of foam system which plugged the formation water layer were studied by means of the experimental model which simulated the real conditions of oil wells existing channeling.Above all,the influence factors including reservoir pressure,permeability,oil saturation and gas-to-liquid ratio were studied through dynamic experiment.Then,in light of the technology characteristics of foam injection in oil field,the comparison between gas-liquid and liquid-gas injection modes was studied.The result shows that the gas-liquid injection mode can ensure the foam injectivity and plugging performance.The plugging validity of nitrogen foam injected into the formation water layer was evaluated in different plugging pressure gradients by the dynamic method which is more reasonable than the static evaluation method in laboratory.The research demonstrates that the plugging validity period of foam decreases with plugging pressure gradient increasing.If the plugging pressure gradient is 0.15 MPa/m,the validity period is 160 h.Finally,a empirical equation and a plate about the plugging validity and the plugging pressure gradient were obtained for forecasting the validity period of foam.展开更多
基金Project(50974046/E041607) supported by the National Natural Science Foundation of China
文摘Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld was welded to a stainless steel pipe with laser spot welding process.The microstructure of the welds was examined with an optical microscope and the elemental distribution in the welds was measured by electron probe microanalysis(EPMA).The results show that TiC compounds dispersively distribute in the NiTi SMA TIG weld.However,the amount of TiC compounds greatly decreases around the fusion boundary of the laser spot weld between the NiTi SMA and stainless steel.Mutual diffusion between NiTi shape memory alloy and stainless steel happen within a short distance near the fusion boundary,and intermetallic compounds such as Ni3Ti+(Fe,Ni)Ti appear around the fusion boundary.
文摘Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age) were selected for percutaneous closure of ASD bytrans-esophageal echocardiography, which was also used to monitor the procedure, to select theappropriate size of the Amplatzer device, to verify its position, and to access the immediateresults of the procedure. During the follow-up, transthoracic echocardiography (TTE) or TEE was usedto evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiacchamber diameters. Results: The mean ASD diameter by TTE ([19. 1 +- 5. 8] mm) was significantlysmaller (P< 0. 001) than the stretched diameter of the ASD (25. 1 +- 6. 4) mm. There are nosignificant differences between the TEE -measured value (23. 5+_6. 2) mm and the stretched diameterof the ASD (P > 0. 05). Due to proper patient selection all procedures were successful. There wasimmediate and complete closure in 61/62 patients, only one patients had trivial residual shunt.Follow- up was performed using TTE or TEE right after operation, 1 d, 1 month, 3 months, 6 monthsand yearly thereafter. Ail, patients remain asymptomatic without any clinical or technical problems.Conclusion: With the aid of TEE, percutaneous closure of ASD can be performed successfully, safely,and effectively.
文摘Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patients with PDA (n = 25) and ASD ( n = 16), confirmed byechocardiography, were treated by transcatheterization. Amplatzer occluder device was placed by thetranscatheterization with the image support of X-ray and transthoracic echocardiography ( TTE) . TheTTE, ECG and X-ray examination were engaged to evaluate the therapeutic results on the time pointsof 24 h , 1, 3 , 6, 12 months after the operation, and all these cases were engaged to the follow-upexamination. Results: The cardioangiographic diameter was 13.0-28.0 mm ([19.3+-4.9] mm) in ASD and2.0-7.7 mm ([3.9+-1.5] mm) in PDA . The diameter of the Amplatzer occluder selected were 13.0-30.0mm ( [20.6+-5.1] mm) in ASD and 4.0-12.0 mm ([6.6+-1.9] mm) in PDA , respectively. All the Amplatzeroccluders were placed successfully. There were no complications during and after the operation.Very small residual shunt was still found soon after the operation in 10 cases , and there were noresidual or recanalization after three months of the operation. The pulmonary artery pressure andheart size were significantly decreased in follow-up examination . Conclusion: Transcatheteringclosure with Amplatzer device is an effective, simple and safe technique in the treatment of ASD andPDA in children.
文摘Background Coronary artery fistula (CAF) is a rare anomaly.Transcatheter CAF closure has been introduced using various materials,but only few data are available on the Guglielmi detachable coil (GDC).The advantage of using GDC for transcatheter CAF closure is more controllable,therefore much safer when compared to other coils.This report is about our experience in transcatheter closure of CAF using fibered GDC in our hospital.Methods & Results From 2002 to 2007,there were 10 patients with CAFs (age range:28 to 56 year-old,7 males) who underwent transcatheter CAF closure.There were a total of 19 CAFs which originated from right coronary (n =5),left circumflex (n =3),left anterior descending artery (n =10) and left main trunk (n =1).Median number of coil deployment for each fistula was 3 (range:1 to 6).The pulmonary artery was the most common site of the distal communication of CAFs (n =14),followed by right atrium (n =3),left atrium (n =1) and left ventricle (n =1).Immediate coronary angiography after GDC deployment revealed no residual shunt in 12 (63.2%) CAFs,significant reduction of the flow in 5 (26.3%),while 2 (10.5%) could not be closed due to small size.Nine (90%) patients underwent a repeated angiography within 3 to 8 months.Among 12 CAFs that were occluded immediately post-deployment,there were 2 CAFs with insignificant residual flow.Among 6 CAFs with significantly decreased flow immediately post-deployment,2 were occluded totally in the follow-up angiography.In total,12 (70.5%) CAFs were occluded completely and 5 (29.5%) CAFs still had insignificant residual flow,which did not need any additional coil deployment.During a mean follow up of 4.3 ± 0.7 year,all patients remained symptom and complication free.Conclusions The fibered GDC is a safe and effective method for percutaneous closure of the CAFs.
文摘A 54-year-old female patient with congenital heart disease had a persistent complete left bundle branch block three months after closure by an Amplatzer ventricular septal defect occluder. Nine months later, the patient suffered from chest distress, palpitation, and sweating at daily activities, and her 6-min walk distance decreased significantly (155 m). Her echocardiography showed increased left ventricular end-diastolic diameter with left ventricular ejection fraction of 37%. Her symptoms reduced significantly one week after received cardiac resynchronization therapy. She had no symptoms at daily activities, and her echo showed left ventricular ejection fraction of 46%and 53%. Moreover, left ventricular end-diastolic diameter decreased 6 and 10 months after cardiac resynchronization therapy, and 6-min walk dis-tance remarkably increased. This case demonstrated that persistent complete left bundle branch block for nine months after transcatheter closure with ventricular septal defect Amplatzer occluder could lead to left ventricular enlargement and a significant decrease in left ventricular systolic function. Cardiac resynchronization therapy decreased left ventricular end-diastolic diameter and increased left ventricular ejection fraction, thereby improving the patient’s heart functions.
文摘Repeat surgery has usually been considered the first choice to solve paravalvular leaks of prosthetic valves, but it cames a high operative risk, a high mortality rate and an increased risk for re-leaks. Percutaneous closure of such defects is possible, and different approaches and devices are used for this purpose. For mitral paravalvular leaks, constructing an arterio-venous wire loop for delivering the closure device through an antegrade approach is the most commonly used technique. Transcatheter closure can also be performed through a transapical approach or retrograde transfemoral arterial approach. We present a case of 68-year-old man with a mitral paravalvular leak that was suc- cessfully closed using an Amplatzer~ Duct Occluder H, via retrograde transfemoral arterial approach under three-dimensional transesophag- eal echocardiographic guidance, without the use of a wire loop. The initial attempt to cross the paravalvular defect was unsuccessful, but the obstacle was finally overcome by introducing complex interventional techniques.
文摘We report the management of a patient with secundum atrial septal defect (ASD) and severe pulmonary hypertension. A 65-year-old male with recently diagnosed atrial septal defect was referred to our centre for decompensated right heart failure with rest and exercise induced dispnea and severe pulmonary hypertension. Right heart catheterization confirmed a mean pulmonary pressure of about 55 mmHg and a Qp/Qs of 2.7. An occlusion test with a compliant large balloon demonstrated partial fall of pulmonary arterial pressure. The implantation of a home-made fenestrated Amplatzer ASD Occluder (ASO) was planned in order to decrease left-to-right shunt and promote further decrease of pulmonary arterial pressure in the long-term. Thus, by means of mechanical intracardiac echocardiography study with a 9F 9 MHz Ultralce catheter (Boston Scientific Corp.), we selected a 34 mm ASO for implantation. Four millimeter fenestration was made inflating a 4 mm non-compliant coronary balloon throughout the waist of the ASO, which was successfully implanted under intmcardiac echocardiography. After six months, a decrease of pulmonary arterial pressure to 24 mmHg and full compensated right heart failure was observed on transthoracic echocardiography and clinical examination. This case suggests that Wanscatheter closure with home-made fenestrated ASD in elderly patients with severe pulmonary hypertension is feasible.
文摘Aortopuhnonary window is a rare congenital cardiac malformation, which is previously repaired using cardiopulmonary bypass. However, some cases were reported to repair the aortopulmonary septal defect by transcathetcr closure. Here we present a 30 year-old woman with a 7-mm aortopulmonary window, who was successfully treated using a modified double-disk PmVSD occluder
文摘Platypnea orthodeoxia syndrome is associated with dyspnea and arterial oxygen desamration accentuated by an upright posture. It can be secondary to an intracardiac shunt. We report a case of platypnea-orthodeoxia syndrome (POS) in a 58-year old male patient who had a pre-existing patent foramen ovale (PFO) and substantial pulmonary pathologies. He was successfully treated by percutaneous transcatheter closure of the PFO. Our case highlights the importance of recognition of this rare syndrome in patients who present with unexplained hy- poxia for whom transcatheter closure of the interatrial shunt can be safely carded out.
文摘Hemolytic anemia after implantation of an artificial mitral valve is a rare but recognized complication of surgery. The presence of paravalvular leak after surgery and the necessity of using oral anticoagulants causes that anemia emerges as a severe and potentially fatal issue.
基金Project(2006CB705800)supported by the National Basic Research Program of China
文摘In order to present a new method for plugging channeling in oil field,the injection modes and validity period of foam system which plugged the formation water layer were studied by means of the experimental model which simulated the real conditions of oil wells existing channeling.Above all,the influence factors including reservoir pressure,permeability,oil saturation and gas-to-liquid ratio were studied through dynamic experiment.Then,in light of the technology characteristics of foam injection in oil field,the comparison between gas-liquid and liquid-gas injection modes was studied.The result shows that the gas-liquid injection mode can ensure the foam injectivity and plugging performance.The plugging validity of nitrogen foam injected into the formation water layer was evaluated in different plugging pressure gradients by the dynamic method which is more reasonable than the static evaluation method in laboratory.The research demonstrates that the plugging validity period of foam decreases with plugging pressure gradient increasing.If the plugging pressure gradient is 0.15 MPa/m,the validity period is 160 h.Finally,a empirical equation and a plate about the plugging validity and the plugging pressure gradient were obtained for forecasting the validity period of foam.