Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop me...Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sectional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is confirmed by a fundamental fluid dynamics analysis.展开更多
The hydrodynamics and mass transfer of Plum Flower Mini Ring (PFMR), Pall Ring and Intalox Saddle were studied in a 600 mm diameter column with air-oxygen-water system over a wide range of liquid loads. It was shown f...The hydrodynamics and mass transfer of Plum Flower Mini Ring (PFMR), Pall Ring and Intalox Saddle were studied in a 600 mm diameter column with air-oxygen-water system over a wide range of liquid loads. It was shown from the experiments that PFMR had much lower resistance, larger throughput and higher mass transfer efficiency than Pall Ring and Intalox Saddle. It was clear from the comparison that existing equations could not predict the performance of packings very well at high liquid loads. Therefore, new semi-empirical equations of pressure drop, flooding gas velocity and height of transfer unit (HTU) were proposed based on the experimental data.展开更多
Experimental study on hydrodynamics and mass transfer efficiencyof jet coflow packing tray (JCPT) was conducted in a φ285 mm columnand φ200 mm column, respectively. Compared with new vertical sievetray which has bee...Experimental study on hydrodynamics and mass transfer efficiencyof jet coflow packing tray (JCPT) was conducted in a φ285 mm columnand φ200 mm column, respectively. Compared with new vertical sievetray which has been applied in the petrochemical industry since 1968,the JCPT has lower pressure drop, higher capacity and higher masstransfer efficiency, and seems promising in commercial application.展开更多
文摘Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sectional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is confirmed by a fundamental fluid dynamics analysis.
文摘The hydrodynamics and mass transfer of Plum Flower Mini Ring (PFMR), Pall Ring and Intalox Saddle were studied in a 600 mm diameter column with air-oxygen-water system over a wide range of liquid loads. It was shown from the experiments that PFMR had much lower resistance, larger throughput and higher mass transfer efficiency than Pall Ring and Intalox Saddle. It was clear from the comparison that existing equations could not predict the performance of packings very well at high liquid loads. Therefore, new semi-empirical equations of pressure drop, flooding gas velocity and height of transfer unit (HTU) were proposed based on the experimental data.
文摘Experimental study on hydrodynamics and mass transfer efficiencyof jet coflow packing tray (JCPT) was conducted in a φ285 mm columnand φ200 mm column, respectively. Compared with new vertical sievetray which has been applied in the petrochemical industry since 1968,the JCPT has lower pressure drop, higher capacity and higher masstransfer efficiency, and seems promising in commercial application.