O-nitro-phenol wastewater which contains refractory organic matters can not be degraded by conventional biological methods. In this work, o-nitro-phenol wastewater was effectively treated using magnetization-enhanced ...O-nitro-phenol wastewater which contains refractory organic matters can not be degraded by conventional biological methods. In this work, o-nitro-phenol wastewater was effectively treated using magnetization-enhanced oxidation by NaCIO solutions. The pollutant concentrations in wastewater were 250 mg/L o-nitro-phenol, 2,000 mg/L CODcr and 150 times color. The experimental results show that, using the method in this work, 94.4% o-nitro-phenol, 94.2% CODCr and 100% color can be removed at pH 6, 200 mg charcoal, 8 mL oxidizer, 5 min reaction time in 1000 mL wastewater. The treatment can be enhanced under magnetic field. CODCr and o-nitro-phenol removal can keep unchanged while the reaction time can be reduced to 3 min when the intensity of magnetic field was 60 mT.展开更多
文摘O-nitro-phenol wastewater which contains refractory organic matters can not be degraded by conventional biological methods. In this work, o-nitro-phenol wastewater was effectively treated using magnetization-enhanced oxidation by NaCIO solutions. The pollutant concentrations in wastewater were 250 mg/L o-nitro-phenol, 2,000 mg/L CODcr and 150 times color. The experimental results show that, using the method in this work, 94.4% o-nitro-phenol, 94.2% CODCr and 100% color can be removed at pH 6, 200 mg charcoal, 8 mL oxidizer, 5 min reaction time in 1000 mL wastewater. The treatment can be enhanced under magnetic field. CODCr and o-nitro-phenol removal can keep unchanged while the reaction time can be reduced to 3 min when the intensity of magnetic field was 60 mT.