Objective:The Consolidated Standards for Reporting of Trials(CONSORT) statement has already proved to be an efficient standard for reporting quality of randomized controlled trials(RCTs).However,most of the Chinese me...Objective:The Consolidated Standards for Reporting of Trials(CONSORT) statement has already proved to be an efficient standard for reporting quality of randomized controlled trials(RCTs).However,most of the Chinese medical journals have not endorsed the CONSORT statement.The current situation about the reporting quality of RCTs in Chinese medical journals is still unclear.The purpose of the study was to evaluate the reporting quality of RCTs on papers published in 5 leading Chinese medical journals.Methods:We evaluated 232 original RCT papers using a reporting quality scale based on CONSORT statement from 2001 to 2006 in 5 Chinese medical journals(Journal type 1) without adoption of CONSORT and Chinese Journal of Evidence-based Medicine(Journal type 2) which adopted CONSORT in 2004.We measured the inclusion of 26 items for the reporting quality scale and 6 core items of each RCT report,gave score to each item and calculated the total score obtained in each report and the proportion of reports including individual items.The reporting quality of RCT trials from 2001 to 2003(pre-adoption period) was compared with that from 2004 to 2006(post-adoption period).Results:The average reporting quality of RCTs was moderate(mean score,15.18),and the mean score of the 6 core items was low(mean score,1.09) in 5 leading journals.The difference in the total score and the score of the 6 core items between pre-adoption period(2001-2003) and post-adoption period(2004-2006) was statistically significant(P=0.003;P=0.000).Interaction between journal type and period was not significant(F=0.76;P=0.383).We concluded that the change tendency of reporting quality between Journal type 1 and 2 was not different.But as to the core items of sequence concealment and intention-to-treat analysis,the increases were greater for Journal type 2 when evaluated against Journal type 1(P=0.038;P=0.016).Conclusion:The reporting quality of RCT trials in 5 leading Chinese medical journals is improving.However,the lack of important items in RCT trials remains a serious problem.We recommend the endorsement of the Consolidated Standards for Reporting of Trials statement in Chinese medical journals and the continuing education on evidence-based medicine in China.展开更多
We report that atomically thin two-dimensional silicon quantum sheets(2D Si QSs),prepared by a scalable approach coupling chemical delithiation and cryo-assisted exfoliation,can serve as a highperformance brain photon...We report that atomically thin two-dimensional silicon quantum sheets(2D Si QSs),prepared by a scalable approach coupling chemical delithiation and cryo-assisted exfoliation,can serve as a highperformance brain photonic nanoagent for orthotopic glioma theranostics.With the lateral size of approximately 14.0 nm and thickness of about 1.6 nm,tiny Si QSs possess high mass extinction coefficient of 27.5 Lg^(-1)cm^(-1)and photothermal conversion efficiency of 47.2%at 808 nm,respectively,concurrently contributing to the best photothermal performance among the reported 2 D mono-elemental materials(Xenes).More importantly,Si QSs with low toxicity maintain the trade-off between stability and degradability,paving the way for practical clinical translation in consideration of both storage and action of nanoagents.In vitro Transwell filter experiment reveals that Si QSs could effectively go across the b End.3 cells monolayer.Upon the intravenous injection of Si QSs,orthotopic brain tumors are effectively inhibited under the precise guidance of photoacoustic imaging,and the survival lifetime of brain tumor-bearing mice is increased by two fold.Atomically thin Si QSs with strong light-harvesting capability are expected to provide an effective and robust 2D photonic nanoplatform for the management of brain diseases.展开更多
It is interesting to maximize the amount of information we can obtain from one experiment on a single sample. In obtaining all the thermodynamic properties of some materials from their experimental heat capacity data ...It is interesting to maximize the amount of information we can obtain from one experiment on a single sample. In obtaining all the thermodynamic properties of some materials from their experimental heat capacity data only, we aim to get the tempera- ture-independent energy spectrum. However, all the practical measured energy spectra depend on the temperature of experi- ments. One promising method to obtain the temperature-independent energy spectrum is to solve the so-called specific heat-phonon spectrum inversion (SPI) problem. Here we show, by developing a new practical solution method of SPI, the phonon spectrum of the negative thermal expansion material ZrW208 is obtained. This phonon spectrum is tempera- ture-independent and almost method independent. Hence all the thermodynamic properties of ZrW208, such as thermodynamic potential, entropy, Helmholtz free energy, etc. are obtained by heat capacity only.展开更多
文摘Objective:The Consolidated Standards for Reporting of Trials(CONSORT) statement has already proved to be an efficient standard for reporting quality of randomized controlled trials(RCTs).However,most of the Chinese medical journals have not endorsed the CONSORT statement.The current situation about the reporting quality of RCTs in Chinese medical journals is still unclear.The purpose of the study was to evaluate the reporting quality of RCTs on papers published in 5 leading Chinese medical journals.Methods:We evaluated 232 original RCT papers using a reporting quality scale based on CONSORT statement from 2001 to 2006 in 5 Chinese medical journals(Journal type 1) without adoption of CONSORT and Chinese Journal of Evidence-based Medicine(Journal type 2) which adopted CONSORT in 2004.We measured the inclusion of 26 items for the reporting quality scale and 6 core items of each RCT report,gave score to each item and calculated the total score obtained in each report and the proportion of reports including individual items.The reporting quality of RCT trials from 2001 to 2003(pre-adoption period) was compared with that from 2004 to 2006(post-adoption period).Results:The average reporting quality of RCTs was moderate(mean score,15.18),and the mean score of the 6 core items was low(mean score,1.09) in 5 leading journals.The difference in the total score and the score of the 6 core items between pre-adoption period(2001-2003) and post-adoption period(2004-2006) was statistically significant(P=0.003;P=0.000).Interaction between journal type and period was not significant(F=0.76;P=0.383).We concluded that the change tendency of reporting quality between Journal type 1 and 2 was not different.But as to the core items of sequence concealment and intention-to-treat analysis,the increases were greater for Journal type 2 when evaluated against Journal type 1(P=0.038;P=0.016).Conclusion:The reporting quality of RCT trials in 5 leading Chinese medical journals is improving.However,the lack of important items in RCT trials remains a serious problem.We recommend the endorsement of the Consolidated Standards for Reporting of Trials statement in Chinese medical journals and the continuing education on evidence-based medicine in China.
基金supported by the National Key Research and Development Program of China:Scientific and Technological Innovation Cooperation of Mainland and Macao(2017YFE0120000)the National Natural Science Foundation of China(31800834,81527901,81571745,91859117,81771906,81827807,81901812,and 52071120)+6 种基金the Open Foundation of Shenzhen Bay Laboratory(SZBL2019062801005)the Fundamental Research Funds for the Central Universities(JZ2020HGTB0031 and JZ2018HGPA0273)the Science and Technology Key Project of Shenzhen(JCYJ20160229200902680)the Shenzhen Key Laboratory of Ultrasound Imaging and Therapy(ZDSYS201802061806314)the Shenzhen Double Chain Grant([2018]256)the Natural Science Foundation of Guangdong Province(2014A030312006)the China Postdoctoral Science Foundation(2019 M653129)。
文摘We report that atomically thin two-dimensional silicon quantum sheets(2D Si QSs),prepared by a scalable approach coupling chemical delithiation and cryo-assisted exfoliation,can serve as a highperformance brain photonic nanoagent for orthotopic glioma theranostics.With the lateral size of approximately 14.0 nm and thickness of about 1.6 nm,tiny Si QSs possess high mass extinction coefficient of 27.5 Lg^(-1)cm^(-1)and photothermal conversion efficiency of 47.2%at 808 nm,respectively,concurrently contributing to the best photothermal performance among the reported 2 D mono-elemental materials(Xenes).More importantly,Si QSs with low toxicity maintain the trade-off between stability and degradability,paving the way for practical clinical translation in consideration of both storage and action of nanoagents.In vitro Transwell filter experiment reveals that Si QSs could effectively go across the b End.3 cells monolayer.Upon the intravenous injection of Si QSs,orthotopic brain tumors are effectively inhibited under the precise guidance of photoacoustic imaging,and the survival lifetime of brain tumor-bearing mice is increased by two fold.Atomically thin Si QSs with strong light-harvesting capability are expected to provide an effective and robust 2D photonic nanoplatform for the management of brain diseases.
基金supported by the National Natural Science Foundation of China (Grant Nos. 10675031,10375012 and 19975009)the Department of Education of Zhejiang Province (Grant No. Y200906911)
文摘It is interesting to maximize the amount of information we can obtain from one experiment on a single sample. In obtaining all the thermodynamic properties of some materials from their experimental heat capacity data only, we aim to get the tempera- ture-independent energy spectrum. However, all the practical measured energy spectra depend on the temperature of experi- ments. One promising method to obtain the temperature-independent energy spectrum is to solve the so-called specific heat-phonon spectrum inversion (SPI) problem. Here we show, by developing a new practical solution method of SPI, the phonon spectrum of the negative thermal expansion material ZrW208 is obtained. This phonon spectrum is tempera- ture-independent and almost method independent. Hence all the thermodynamic properties of ZrW208, such as thermodynamic potential, entropy, Helmholtz free energy, etc. are obtained by heat capacity only.