Physicians previously thought that heart disease was rare in patients with end stage liver disease. However, recent evidence shows that the prevalence of ischemic heart disease and cardiomyopathy is increased in trans...Physicians previously thought that heart disease was rare in patients with end stage liver disease. However, recent evidence shows that the prevalence of ischemic heart disease and cardiomyopathy is increased in transplant candidates compared to most other surgical candidates. Investigators estimate that up to 26% of all liver transplant candidates have at least one critical coronary artery stenosis and that at least half of these patients will die perioperatively of cardiac complications. Cardiomyopathy also occurs in greater frequency. While all patients with advanced cardiac disease have defects in cardiac performance, a larger than expected number of patients have classical findings of dilated, restrictive and hypertropic cardiomyopathy. This may explain why up to 56% of patients suffer from hypoxemia due to pulmonary edema following transplant surgery. There is considerable controversy on how to screen transplant candidates for the presence of heart disease. Questions focus upon, which patients should be screened and what tests should be used. This review examines screening strategies for transplant candidates and details the prognostic value of common tests used to identify ischemic heart disease. We also review the physiological consequences of cardiomyopathy in transplant candidates and explore the specific syndrome of "cirrhotic cardiomyopathy".展开更多
Noise-assisted multivariate empirical mode decomposition(NA-MEMD) is suitable to analyze multichannel electroencephalography(EEG) signals of non-stationarity and non-linearity natures due to the fact that it can provi...Noise-assisted multivariate empirical mode decomposition(NA-MEMD) is suitable to analyze multichannel electroencephalography(EEG) signals of non-stationarity and non-linearity natures due to the fact that it can provide a highly localized time-frequency representation.For a finite set of multivariate intrinsic mode functions(IMFs) decomposed by NA-MEMD,it still raises the question on how to identify IMFs that contain the information of inertest in an efficient way,and conventional approaches address it by use of prior knowledge.In this work,a novel identification method of relevant IMFs without prior information was proposed based on NA-MEMD and Jensen-Shannon distance(JSD) measure.A criterion of effective factor based on JSD was applied to select significant IMF scales.At each decomposition scale,three kinds of JSDs associated with the effective factor were evaluated:between IMF components from data and themselves,between IMF components from noise and themselves,and between IMF components from data and noise.The efficacy of the proposed method has been demonstrated by both computer simulations and motor imagery EEG data from BCI competition IV datasets.展开更多
A 78-year-old man with a history of mitral valve prolapse underwent echocardiography during his cardiological check-up examination in 2011 in a symptom-free stage. Echocardiography revealed akinesis of the inferior se...A 78-year-old man with a history of mitral valve prolapse underwent echocardiography during his cardiological check-up examination in 2011 in a symptom-free stage. Echocardiography revealed akinesis of the inferior septum and inferobasal free wall as a novel finding suggesting a distal right coronary artery (RCA) lesion (Figure 1). The systolic left ventricular function was normal. Earlier echocardiographies did not show wall motion abnormalities.展开更多
In order to reduce the noise and vibration of the diesel engine,it is crucial to exactly identify the engine noise source character.Based on "two-microphone" method,the sound intensity measurement of a vehic...In order to reduce the noise and vibration of the diesel engine,it is crucial to exactly identify the engine noise source character.Based on "two-microphone" method,the sound intensity measurement of a vehicle four-stroke diesel engine was carried out in a hemi-anechoic chamber.Then the sound intensity contour maps were obtained from the measurement results and the main noise components of different frequencies on all the measurement surfaces were picked out to construct contour maps.By analysizing the relationship between the characteristics of contour maps and the space distribution of the engine compartment,the major sources of the exterior radiation noise of the diesel engine were identified.The results provided a creditable basis for improving the noise performance of the engine in the next phase.展开更多
To effectively suppress white noise and preserve more useful components of electrocardiogram(ECG) signal, a novel de-noising method based on morphological component analysis(MCA) is proposed. MCA is a method which all...To effectively suppress white noise and preserve more useful components of electrocardiogram(ECG) signal, a novel de-noising method based on morphological component analysis(MCA) is proposed. MCA is a method which allows us to separate features contained in an original signal when these features present different morphological aspects. According to the features of ECG, we used the UWT dictionary to sparsely represent mutated component, and used the DCT dictionary to sparsely represent smooth component. The experimental results of the samples choosing from MIT-BIH databases show that the MCA-based method is effective for white noise removal.展开更多
文摘Physicians previously thought that heart disease was rare in patients with end stage liver disease. However, recent evidence shows that the prevalence of ischemic heart disease and cardiomyopathy is increased in transplant candidates compared to most other surgical candidates. Investigators estimate that up to 26% of all liver transplant candidates have at least one critical coronary artery stenosis and that at least half of these patients will die perioperatively of cardiac complications. Cardiomyopathy also occurs in greater frequency. While all patients with advanced cardiac disease have defects in cardiac performance, a larger than expected number of patients have classical findings of dilated, restrictive and hypertropic cardiomyopathy. This may explain why up to 56% of patients suffer from hypoxemia due to pulmonary edema following transplant surgery. There is considerable controversy on how to screen transplant candidates for the presence of heart disease. Questions focus upon, which patients should be screened and what tests should be used. This review examines screening strategies for transplant candidates and details the prognostic value of common tests used to identify ischemic heart disease. We also review the physiological consequences of cardiomyopathy in transplant candidates and explore the specific syndrome of "cirrhotic cardiomyopathy".
基金Projects(61201302,61372023,61671197)supported by the National Natural Science Foundation of ChinaProject(201308330297)supported by the State Scholarship Fund of ChinaProject(LY15F010009)supported by Zhejiang Provincial Natural Science Foundation,China
文摘Noise-assisted multivariate empirical mode decomposition(NA-MEMD) is suitable to analyze multichannel electroencephalography(EEG) signals of non-stationarity and non-linearity natures due to the fact that it can provide a highly localized time-frequency representation.For a finite set of multivariate intrinsic mode functions(IMFs) decomposed by NA-MEMD,it still raises the question on how to identify IMFs that contain the information of inertest in an efficient way,and conventional approaches address it by use of prior knowledge.In this work,a novel identification method of relevant IMFs without prior information was proposed based on NA-MEMD and Jensen-Shannon distance(JSD) measure.A criterion of effective factor based on JSD was applied to select significant IMF scales.At each decomposition scale,three kinds of JSDs associated with the effective factor were evaluated:between IMF components from data and themselves,between IMF components from noise and themselves,and between IMF components from data and noise.The efficacy of the proposed method has been demonstrated by both computer simulations and motor imagery EEG data from BCI competition IV datasets.
文摘A 78-year-old man with a history of mitral valve prolapse underwent echocardiography during his cardiological check-up examination in 2011 in a symptom-free stage. Echocardiography revealed akinesis of the inferior septum and inferobasal free wall as a novel finding suggesting a distal right coronary artery (RCA) lesion (Figure 1). The systolic left ventricular function was normal. Earlier echocardiographies did not show wall motion abnormalities.
基金supported by programfor the Top Young Academic Leaders of Higher Learning Institutions of Shanxi(2009)Natural Science Foundation of Shanxi Province,China(No.2010011031-2)
文摘In order to reduce the noise and vibration of the diesel engine,it is crucial to exactly identify the engine noise source character.Based on "two-microphone" method,the sound intensity measurement of a vehicle four-stroke diesel engine was carried out in a hemi-anechoic chamber.Then the sound intensity contour maps were obtained from the measurement results and the main noise components of different frequencies on all the measurement surfaces were picked out to construct contour maps.By analysizing the relationship between the characteristics of contour maps and the space distribution of the engine compartment,the major sources of the exterior radiation noise of the diesel engine were identified.The results provided a creditable basis for improving the noise performance of the engine in the next phase.
基金Natural Science Foundatoin of Fujian Province of Chinagrant number:2012J01280
文摘To effectively suppress white noise and preserve more useful components of electrocardiogram(ECG) signal, a novel de-noising method based on morphological component analysis(MCA) is proposed. MCA is a method which allows us to separate features contained in an original signal when these features present different morphological aspects. According to the features of ECG, we used the UWT dictionary to sparsely represent mutated component, and used the DCT dictionary to sparsely represent smooth component. The experimental results of the samples choosing from MIT-BIH databases show that the MCA-based method is effective for white noise removal.