An up-conversion mixer implemented in a 0.35μm SiGe BiCMOS technology for a double conversion cable TV tuner is described, The mixer converts the 100MHz to 1000MHz band to the Intermediate Frequency of 1GHz above. Th...An up-conversion mixer implemented in a 0.35μm SiGe BiCMOS technology for a double conversion cable TV tuner is described, The mixer converts the 100MHz to 1000MHz band to the Intermediate Frequency of 1GHz above. The mixer meets the linearity and noise figure requirements for a TV tuner. The noise figure (IF) of 19.2-17.5dB, ldB compression of 12.1dBm, and gain of-1-0.7dB in the 900MHz band are achieved at a supply voltage of 5V. The power consumption is 47mW.展开更多
Intravascular ultrasound can provide clear real-time cross-sectional images,including lumen and plaque.In practice,to identify the plaques tissues in different pathological changes is very important.However,the graysc...Intravascular ultrasound can provide clear real-time cross-sectional images,including lumen and plaque.In practice,to identify the plaques tissues in different pathological changes is very important.However,the grayscale differences of them are not so apparent.In this paper a new textural characteristic space vector was formed by the combination of Co-occurrence Matrix and fraction methods.The vector was projected to the new characteristic space after multiplied by a projective matrix which can best classify those plaques according to the Fisher linear discriminant.Then the classification was completed in the new vector space.Experimental results found that the veracity of this classification could reach up to 88%,which would be an accessorial tool for doctors to identify each plaque.展开更多
基金Supported by the National Natural Science Foundation of China (No.90207008).
文摘An up-conversion mixer implemented in a 0.35μm SiGe BiCMOS technology for a double conversion cable TV tuner is described, The mixer converts the 100MHz to 1000MHz band to the Intermediate Frequency of 1GHz above. The mixer meets the linearity and noise figure requirements for a TV tuner. The noise figure (IF) of 19.2-17.5dB, ldB compression of 12.1dBm, and gain of-1-0.7dB in the 900MHz band are achieved at a supply voltage of 5V. The power consumption is 47mW.
文摘Intravascular ultrasound can provide clear real-time cross-sectional images,including lumen and plaque.In practice,to identify the plaques tissues in different pathological changes is very important.However,the grayscale differences of them are not so apparent.In this paper a new textural characteristic space vector was formed by the combination of Co-occurrence Matrix and fraction methods.The vector was projected to the new characteristic space after multiplied by a projective matrix which can best classify those plaques according to the Fisher linear discriminant.Then the classification was completed in the new vector space.Experimental results found that the veracity of this classification could reach up to 88%,which would be an accessorial tool for doctors to identify each plaque.