It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with d...It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with dump is introduced in the letter, numerical analysis is carried out by four-order Runge-Kutta method. An oscillator array is designed according to the frequency of the ultrasonic wave. When the external signals are inputted, computational algorithm is used to scan the array in turn and analyze the result, and the frequency can be determined. Based on the methods above, detecting the carotid blood flow speed accurately is realized. The Signal-to-Noise Ratio (SNR) of-20.23dB is obtained by the result of experiments. In conclusion, the SNR has been improved and the precision of the measured bloodstream speed has been increased, which can be 0.069% to 0.13%.展开更多
There are complex heterogeneous entities in the underground medium,and the heterogeneous scale has a substantial impact on wave propagation.In this study,we used a set of 11 samples of glass beads as high-velocity het...There are complex heterogeneous entities in the underground medium,and the heterogeneous scale has a substantial impact on wave propagation.In this study,we used a set of 11 samples of glass beads as high-velocity heterogeneous bodies to evaluate the impact of such heterogeneous bodies on the propagation of P-wave.We vary the heterogeneous scale by changing the diameter of the glass beads from 0.18 to 11 mm while keeping the same volume proportion(10%)of the beads for the set of 11 samples.The pulse transmission method was used to record measurements at the ultrasonic frequencies of 0.34,0.61,and 0.84 MHz in the homogeneous matrix.The relationship between P-wave fi eld features and heterogeneity scale,P-wave velocity,and the multiple of the wave number and heterogeneous scale(ka)was observed in the laboratory,which has sparked widespread interest and research.Heterogeneous scale affects P-wave propagation,and its wave field changes are complex.The waveform,amplitude,and velocity of the recorded P-waves correlate with the heterogeneous scale.For the forward scattering while large-scale heterogeneities,noticeable direct and diff racted waves are observed in the laboratory,which indicates that the infl uence of direct and diff racted waves cannot be ignored for large-scale heterogeneities.The relationship between velocity and ka shows frequency dependence;the reason is that the magnitude of change in velocity caused by wave number is diff erent from that caused by heterogeneous scale.According to the change in the recorded waveform,amplitude variation,or the relationship between the velocity measured at diff erent frequencies and the heterogeneous scale,the identifi ed turning points of the ray approximation are all around ka=10.When ka is less than 1,the velocity changes slowly and gradually approaches the eff ective medium velocity.The ray velocity measured for heterogeneous media with large velocity perturbations in the laboratory is signifi cantly smaller than the velocity predicted by the perturbation theory.展开更多
The hypersonic flow at orbital speeds is a fundamental issue for the ground tests of aerospace crafts.The detonation-driven high-enthalpy expansion tube(JF16 expansion tube)was developed to investigate re-entry physic...The hypersonic flow at orbital speeds is a fundamental issue for the ground tests of aerospace crafts.The detonation-driven high-enthalpy expansion tube(JF16 expansion tube)was developed to investigate re-entry physics.A forward detonation cavity(FDC)driver was applied in the JF16 expansion tube to create stable driving flows.The sound speed ratio of the detonated to test gas was examined to minimize the magnitude of test flow perturbations.The acceleration section length,incident shock decay and diaphragms thickness were investigated in detail to obtain optimal operation parameters.Flow visualization was also carried out with schlieren system to demonstrate the test flow stability and the effective test duration.Experimental data showed that the test flow with a velocity of 8.3 km/s and a total enthalpy up to 40 MJ/kg can be generated successfully and the test duration lasts for more than 50μs.展开更多
基金Supported by the National Natural Science Foundation of China (No.60102002)the Huoyingdong Education Foundation (No.81057)the Doctoral Foundation of Hebei Province of China(No.B2004522).
文摘It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with dump is introduced in the letter, numerical analysis is carried out by four-order Runge-Kutta method. An oscillator array is designed according to the frequency of the ultrasonic wave. When the external signals are inputted, computational algorithm is used to scan the array in turn and analyze the result, and the frequency can be determined. Based on the methods above, detecting the carotid blood flow speed accurately is realized. The Signal-to-Noise Ratio (SNR) of-20.23dB is obtained by the result of experiments. In conclusion, the SNR has been improved and the precision of the measured bloodstream speed has been increased, which can be 0.069% to 0.13%.
基金supported by the National Science and Technology Major Project of China(No.2017ZX05005-004).
文摘There are complex heterogeneous entities in the underground medium,and the heterogeneous scale has a substantial impact on wave propagation.In this study,we used a set of 11 samples of glass beads as high-velocity heterogeneous bodies to evaluate the impact of such heterogeneous bodies on the propagation of P-wave.We vary the heterogeneous scale by changing the diameter of the glass beads from 0.18 to 11 mm while keeping the same volume proportion(10%)of the beads for the set of 11 samples.The pulse transmission method was used to record measurements at the ultrasonic frequencies of 0.34,0.61,and 0.84 MHz in the homogeneous matrix.The relationship between P-wave fi eld features and heterogeneity scale,P-wave velocity,and the multiple of the wave number and heterogeneous scale(ka)was observed in the laboratory,which has sparked widespread interest and research.Heterogeneous scale affects P-wave propagation,and its wave field changes are complex.The waveform,amplitude,and velocity of the recorded P-waves correlate with the heterogeneous scale.For the forward scattering while large-scale heterogeneities,noticeable direct and diff racted waves are observed in the laboratory,which indicates that the infl uence of direct and diff racted waves cannot be ignored for large-scale heterogeneities.The relationship between velocity and ka shows frequency dependence;the reason is that the magnitude of change in velocity caused by wave number is diff erent from that caused by heterogeneous scale.According to the change in the recorded waveform,amplitude variation,or the relationship between the velocity measured at diff erent frequencies and the heterogeneous scale,the identifi ed turning points of the ray approximation are all around ka=10.When ka is less than 1,the velocity changes slowly and gradually approaches the eff ective medium velocity.The ray velocity measured for heterogeneous media with large velocity perturbations in the laboratory is signifi cantly smaller than the velocity predicted by the perturbation theory.
基金The National Natural Science Foundation of China (Grant Nos. 10632090 and 10621202)
文摘The hypersonic flow at orbital speeds is a fundamental issue for the ground tests of aerospace crafts.The detonation-driven high-enthalpy expansion tube(JF16 expansion tube)was developed to investigate re-entry physics.A forward detonation cavity(FDC)driver was applied in the JF16 expansion tube to create stable driving flows.The sound speed ratio of the detonated to test gas was examined to minimize the magnitude of test flow perturbations.The acceleration section length,incident shock decay and diaphragms thickness were investigated in detail to obtain optimal operation parameters.Flow visualization was also carried out with schlieren system to demonstrate the test flow stability and the effective test duration.Experimental data showed that the test flow with a velocity of 8.3 km/s and a total enthalpy up to 40 MJ/kg can be generated successfully and the test duration lasts for more than 50μs.