某备煤装置分析小屋预处理改造 被引量:1
1
作者 郝洪伟 毛旭涛 贾永清 《仪器仪表用户》 2017年第12期39-41,共3页
化工企业中气化备煤装置在线分析仪表主要是测量热风炉和循环气中的O2、CO含量,对保证安全生产和提高生产转化率有很重要的指导意义。通过对备煤装置分析小屋预处理的升级改造,彻底消除了备煤装置工艺样气温度高、含水量大、含粉尘量大... 化工企业中气化备煤装置在线分析仪表主要是测量热风炉和循环气中的O2、CO含量,对保证安全生产和提高生产转化率有很重要的指导意义。通过对备煤装置分析小屋预处理的升级改造,彻底消除了备煤装置工艺样气温度高、含水量大、含粉尘量大、负压等诸多不利因素,使工艺样品气预处理系统能够满足在线分析仪表对样气的要求,保证在线分析仪表可靠、长期、准确测量。本文就备煤改造的预处理系统从技术手段、特点、应用等方面进行分析,希望能够对相关人员的工作起到一定的支持作用。 展开更多
关键词 在线分析仪表 预处理系统 备煤装置
下载PDF
Controlling the coal dust at transshipment point: A study of the foam-sol foaming device 被引量:4
2
作者 Xi Zhilin Jiang Manman +1 位作者 Sun Changping Tu Xian 《International Journal of Mining Science and Technology》 SCIE EI 2014年第5期625-630,共6页
In order to effectively control the dust at the transshipment point with foam-sol, this paper attempted to study the characteristics of dust diffusion at transshipment point and the foam-sol foaming device with diffus... In order to effectively control the dust at the transshipment point with foam-sol, this paper attempted to study the characteristics of dust diffusion at transshipment point and the foam-sol foaming device with diffusion outlet was also designed in this paper. To study the diffusion rules of coal dust, fluent discrete phase model was utilized in the numerical simulation, as the coal dust was thrown down at a horizontal velocity of 2.5 m/s. A foam-sol foaming device was designed, through which foaming agent could be automatically sucked into the Venturi by the negative pressure. The automatic controller was also equipped,which could transform the energy of the compressed air into the constant pressure difference so that the gelling agent could be qualitatively added into the gel container. The diffusion outlet that could spray out foam-sol in a continuous, conical and 3D manner was also designed. Moreover, this paper also carried out the contrast experiments on dust removal efficiency among water, aqueous foam and foam-sol. The results clearly show that the symmetrical whirlpools appeared below the inlet where the largest whirlpool diameter was 0.52 m, and the horizontal distance from swirl range to the inlet was approximately0.69 m. By using the self-designed foaming device, the foaming was multiplied by 30 times and the volume ratio with water and foaming agent reached 95%:5%. In this context, the gas pressure was controlled at 0.3 MPa, with gas flow at 15 m3/h and water flow at 0.5 m3/h, with water pressure controlled between0.34 and 0.36 MPa. The foam-sol has the highest dust removal efficiency than other agents. 展开更多
关键词 Coal dust Foaming device Foam-sol Transshipment point Diffusion outlet
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部